Home UFC-1660 UNIT Instruments 1660 Series Precision Analog MFC

UFC-1660 UNIT Instruments 1660 Series Precision Analog MFC

  • Manufacturer: UNIT Instruments

  • Product No.: UFC-1660

  • Condition: In stock

  • Product Type: Mass Flow Controller

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

UFC-1660 UNIT Instruments Analog Mass Flow Controller

The UNIT Instruments UFC-1660 is an analog mass flow controller from the 1660 Series. It combines a high-purity metal-seal gas path with the proven Unit 132 proportional electromagnetic valve. The platform supports semiconductor process gas delivery where pressure capability, repeatable flow regulation, and clean wetted surfaces matter.

This base analog configuration covers full-scale flow ranges from 3 sccm to 30 slm, based on nitrogen-equivalent flow. It uses 0–5 VDC setpoint and monitor signals for equipment integration. Its metal-seal construction and broad pressure envelope make it suitable for high-purity gas panels and semiconductor process tools.

01 | Process Fit: Where the UFC-1660 Belongs

The UFC-1660 addresses gas delivery requirements in semiconductor manufacturing. Its analog control architecture suits equipment that uses conventional voltage-based command and monitoring signals.

  • Plasma etching: Regulates process gas delivery to etch chambers.
  • Chemical vapor deposition (CVD): Supports controlled gas flow during film deposition.
  • Diffusion: Provides repeatable gas delivery for thermal processing equipment.
  • Epitaxy (EPI): Supports gas flow regulation in epitaxial growth systems.
  • Sputtering: Controls process gas supply in physical vapor deposition equipment.
  • High-purity gas panels: Integrates into gas distribution systems using compatible analog controls.

The specified gas compatibility includes non-corrosive and moderately corrosive process gases. The standard calibration is nitrogen-based. Confirm gas compatibility and calibration requirements before applying the controller to a particular process chemistry.

02 | Flow Regulation: Accuracy Across the Working Range

The UFC-1660 provides a 2% to 100% full-scale control range. Its accuracy specification changes according to the operating point, so engineers should evaluate the required process setpoint against the selected range.

Performance Parameter Specification
Full-scale flow range 3 sccm to 30 slm, N2 equivalent
Accuracy above 35% FS ±1% FS, analog model
Accuracy below 35% FS ±0.35% FS, analog model
Repeatability ±0.15% FS, per SEMI E56-96
Linearity ±0.5% FS, per SEMI E27-92
Control range 2% to 100% FS
Fast-start settling time ≤1.0 second, per SEMI E17-91
Soft-start ramp Linear, 20% per second

The fast-start and soft-start specifications describe different operating behaviors. Fast start supports settling after a setpoint change. Soft start applies a controlled linear ramp at 20% per second. Select the appropriate start behavior according to the process sequence and equipment requirements.

03 | Pressure Envelope and Gas Delivery Conditions

The 1660 platform supports demanding gas supply conditions. Its rated pressure limits should be considered separately during system design.

  • Maximum operating pressure: 3,500 kPa (500 psi)
  • Proof pressure: 10,500 kPa (1,500 psi)
  • Differential pressure: 6.65–350 kPa (50 torr–50 psid)
  • Pressure coefficient: 0.007% of reading per psi, N2

Maximum operating pressure defines the stated operating limit. Proof pressure is a separate pressure-resistance rating and should not be treated as a normal operating condition. Differential pressure must also remain within the specified range to support the required flow performance.

04 | High-Purity Flow Path: Metal Seals and Surface Finish

The UFC-1660 uses a metal-sealed wetted assembly designed for high-purity gas service. Its standard internal surface finish is 16 micro-inch Ra, with a 10 micro-inch Ra option specified for applications requiring a finer finish.

Construction Detail Specification
Wetted materials 316L stainless steel, K-M43, 304 stainless steel, and 7Mo
Standard surface finish 16 micro-inch Ra
Optional surface finish 10 micro-inch Ra
Seal type Metal seal, C-seal or W-seal
Seat material Kel-F or metal seat
Leak integrity 1 × 10-10 atm-cc/sec He, per SEMI E16-90

The metal-seal configuration supports applications where elastomer-free sealing is preferred. However, the exact seal and seat configuration should be confirmed against the ordered unit. Do not assume every UFC-1660 uses the same combination.

05 | Unit 132 Valve: Proportional Electromagnetic Control

The UFC-1660 uses the Unit 132 proportional electromagnetic valve for flow regulation. The platform also specifies normally-closed or normally-open solenoid configurations.

  • Valve platform: Unit 132 proportional electromagnetic valve
  • Valve action options: Normally closed or normally open
  • Control function: Proportional gas-flow regulation

Valve action affects the default gas-path state when the valve is not energized. Engineers should verify the required configuration against the tool's shutdown sequence and gas isolation strategy. Confirm the installed valve option before commissioning or replacement.

06 | Analog Interface and Electrical Requirements

This UFC-1660 configuration is the analog base model of the 1660 family. It uses voltage signals for setpoint input and flow monitoring rather than relying on a native digital communication interface.

  • Setpoint input: 0–5 VDC
  • Monitor output: 0–5 VDC
  • Connector options: 20-pin card edge or 9/15-pin D-sub
  • Power supply: +15 VDC, 100 mA maximum
  • Negative supply: -15 VDC, 200 mA maximum
  • Maximum power consumption: 4.5 W
  • Auto-zero: Optional on analog configurations

Before installation, identify the connector type and verify the equipment-side pin assignment. Confirm signal scaling, supply polarity, and available current capacity. Auto-zero availability should also be checked against the specific configuration. The stated standard auto-zero feature on digital models should not be assumed for this analog base model.

07 | Thermal Behavior and Long-Term Stability

The standard UFC-1660 is an unheated model. Its specified operating temperature range is 0–50°C. Temperature and pressure variations can affect measured flow, so system conditions should remain controlled during process operation.

Parameter Specification
Operating temperature 0–50°C (32–122°F)
Heated configuration No; standard unheated version
Zero stability ≤0.6% FS per year, without auto-zero
Zero temperature coefficient 0.05% FS/°C
Span temperature coefficient 0.1% FS/°C

For applications with changing ambient temperature, consider the stated zero and span coefficients when evaluating measurement stability. Where the analog unit does not include auto-zero, include zero verification in the equipment maintenance plan.

08 | Mechanical Envelope and Installation Planning

  • Approximate dimensions (H × W × D): 137 × 127 × 38 mm
  • Footprint: 1.5-inch footprint
  • 1/4 VCR overall length: 124 mm
  • Weight: 1.2 kg (2.65 lb)

Check the applicable mechanical drawing before preparing the mounting plate or gas-line connections. The stated dimensions are approximate. Confirm the connector clearance, port orientation, and overall installed length against the actual unit configuration.

09 | Commissioning Checklist for Equipment Engineers

  1. Identify the gas: Confirm the process gas and its compatibility with the wetted materials and seal configuration.
  2. Verify calibration: The supplied calibration is nitrogen-based. Confirm whether the process requires an applicable gas calibration.
  3. Match the flow range: Check the required operating setpoint against the selected full-scale range and 2–100% FS control range.
  4. Check pressure conditions: Verify supply pressure and differential pressure before enabling flow.
  5. Confirm the valve option: Check normally-open or normally-closed behavior against the equipment's operating sequence.
  6. Inspect the interface: Match the card-edge or D-sub connector, 0–5 VDC signals, and power requirements.
  7. Validate response: Test fast-start settling and soft-start ramp behavior in the actual gas delivery system.
  8. Record baseline values: Document zero output, setpoint response, and operating pressure for future maintenance comparison.

10 | Compliance and Calibration References

The UFC-1660 specifications reference the following standards and certifications:

  • CE: CE certified
  • SEMI E12: Referenced compliance standard
  • SEMI E16-90: Leak integrity reference
  • SEMI E17-91: Fast-start settling-time reference
  • SEMI E27-92: Linearity reference
  • SEMI E56-96: Repeatability reference
  • Calibration: NIST-traceable calibration

Confirm the applicable documentation and configuration-specific compliance records when qualifying the controller for a production tool.

11 | Engineering FAQ

Q1: Can the UFC-1660 replace a mass flow controller that uses a digital communication bus?

Not as a direct electrical substitute. This analog base model uses 0–5 VDC setpoint and monitor signals. A replacement project must verify the host controller's signal interface, connector wiring, scaling, and control logic. If the existing system depends on digital communication, check whether the equipment supports an analog interface before selecting this model.

Q2: What should be considered when selecting C-seal versus W-seal construction?

Selection depends on the specified gas connection, sealing arrangement, and equipment interface. Confirm the required seal geometry and compatible mating hardware from the unit drawing or procurement specification. Do not select a seal solely by its name or assume the two configurations are interchangeable.

Q3: How should engineers evaluate the 10 micro-inch Ra surface-finish option?

Start with the process cleanliness specification and the requirements of the gas distribution system. The standard finish is 16 micro-inch Ra, while 10 micro-inch Ra is an optional configuration. Confirm that the ordered unit includes the required finish and supporting documentation if the process qualification specifies it.

Q4: What can cause a flow reading to shift after a gas panel has been serviced?

Common items to investigate include changed supply pressure, trapped gas, connection contamination, altered line restrictions, and disturbed electrical connections. First stabilize the gas supply and compare the actual differential pressure with the operating requirement. Then verify the zero output and command signal before changing calibration settings.

Q5: How should the soft-start function be considered when sequencing multiple gas lines?

The specified soft-start ramp is linear at 20% per second. When several gas lines start together, consider how their individual ramp profiles affect chamber pressure and process timing. Validate the sequence at the equipment level, especially where gas introduction order or pressure transients influence the process recipe.

UFC-1660 Product Selection Summary

The UNIT Instruments UFC-1660 is an analog high-purity mass flow controller built around the 1660 Series metal-seal platform and Unit 132 proportional electromagnetic valve. It offers 3 sccm to 30 slm N2-equivalent ranges, 0–5 VDC control, and a high-pressure operating envelope. Its configuration is best evaluated by matching gas compatibility, seal type, valve action, connector, and calibration requirements to the existing process equipment.

Contact us for UFC-1660 availability, configuration confirmation, and a quotation.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.