FC-R7700 AERA Analog Gas Flow Controller | FC-R7700 Series
Manufacturer: AERA
Product No.: FC-R7700
Condition: In stock
Product Type: Mass Flow Controller
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
FC-R7700 | AERA Analog Mass Flow Controller
The AERA FC-R7700 is an economical analog mass flow controller designed for precise delivery of inert and other non-corrosive gases. It combines an elastomer-sealed gas path, solenoid control valve, and 0–5 VDC analog interface in a compact package.
With full-scale flow options from 10 sccm to 5 slm, the FC-R7700 supports gas-flow regulation in semiconductor process equipment, vacuum systems, and industrial coating applications. Its standard, unheated construction provides a practical solution for applications that do not require temperature-controlled gas delivery.
Engineering focus: The unit provides ±1% FS accuracy, ±0.2% FS repeatability, and a control range of 2–100% FS. These specifications support stable setpoint control across a broad operating range when the gas, pressure, and installation conditions match the selected configuration.
01 | Performance at a Glance
| Parameter | Specification |
|---|---|
| Manufacturer | AERA |
| Model | FC-R7700 |
| Series | FC-R7700 Series |
| Product Type | Analog Mass Flow Controller (MFC) |
| Full-Scale Flow Range | 10 sccm to 5 slm |
| Accuracy | ≤ ±1% of full scale |
| Repeatability | ≤ ±0.2% of full scale |
| Linearity | ≤ ±0.5% of full scale |
| Control Range | 2–100% of full scale |
| Response Time | Less than 2 seconds to settle within ±2% FS between setpoints |
| Zero Stability | Less than 0.5% FS over one year |
| Operating Temperature | 5 to 45°C (41 to 113°F) |
| Heating Configuration | Standard unheated version |
| Weight | Approximately 1.0 kg (2.2 lb) |
| Compliance | RoHS |
02 | Control Architecture and Gas Compatibility
The FC-R7700 uses an analog command and feedback arrangement. A 0–5 VDC input sets the target flow, while the analog output provides the corresponding flow signal to the host controller or process equipment.
- Command signal: 0–5 VDC analog input.
- Feedback signal: 0–5 VDC analog output.
- Electrical connector: AERA 9-pin D connector.
- Valve mechanism: Solenoid valve.
- Valve configuration: Normally open or normally closed, depending on the ordered version.
- Gas compatibility: Inert and non-corrosive gases, including nitrogen, oxygen, and argon, subject to the specified gas configuration.
Selection note: Confirm the gas calibration and valve configuration before ordering. Oxygen service requires confirmation of material cleanliness and application suitability. Do not assume that every standard configuration is approved for every gas.
03 | Gas Path Materials and Pressure Envelope
| Item | Details |
|---|---|
| Wetted Body Materials | 316/316L stainless steel, PTFE, and magnetic stainless steel |
| Seal Materials | Fluoroelastomer or chloroprene rubber |
| Seal Design | Elastomer-sealed |
| Operating Differential Pressure | 7–40 psiD |
| Normal Operating Pressure | 70 psig |
| Maximum Inlet Pressure | 140 psig |
| Helium Leak Rate | ≤ 1 × 10⁻⁶ atm·cc/sec; also specified as ≤ 1 × 10⁻⁷ Pa·m³/sec |
The elastomer seal design offers an economical option for compatible non-corrosive gas systems. Seal selection matters because fluoroelastomer and chloroprene rubber have different chemical and temperature compatibility limits.
The specified differential pressure is the pressure difference required across the controller. It is not interchangeable with the inlet pressure rating. Maintain the required differential pressure under actual process flow conditions.
04 | Electrical and Mechanical Integration
| Integration Item | Specification |
|---|---|
| Power Supply | +15 VDC ±2% at 25 mA |
| Negative Supply | −15 VDC ±2% at 180 mA |
| Maximum Power | 3.1 W |
| Signal Interface | 0–5 VDC command and output |
| Connector | AERA 9-pin D connector |
| Dimensions (H × W × D) | 119 × 32 × 124 mm |
| Port-to-Port Dimension | 124 mm |
| Body Width | 32 mm |
| Overall Height | 119 mm |
Before installation, check the available mounting space, gas-line alignment, connector access, and power supply capacity. Verify the actual connector pin assignment against the equipment documentation before wiring.
05 | Where the FC-R7700 Fits
- Semiconductor fabrication: Gas delivery for CVD, PVD, etching, diffusion, ion implantation, and sputtering equipment.
- Flat-panel display production: Flow regulation in compatible process-gas supply systems.
- Data storage manufacturing: Gas control for deposition and coating processes.
- Industrial vacuum equipment: Controlled gas injection in non-corrosive gas applications.
- Industrial coating: Flow management for compatible inert-gas processes.
06 | Installation and Commissioning Checklist
- Confirm the model configuration. Match the full-scale flow, gas calibration, seal material, valve action, and connection type to the process requirements.
- Inspect the gas lines. Remove particles, moisture, oil, and other contaminants that could affect the flow path or valve operation.
- Check pressure conditions. Maintain 7–40 psiD differential pressure and verify that the inlet pressure stays within the 140 psig maximum.
- Verify electrical supplies. Provide the specified positive and negative DC rails. Confirm polarity and supply stability before connecting the unit.
- Check analog signals. Confirm the 0–5 VDC command and output ranges, grounding arrangement, and connector pin assignment.
- Perform a zero and flow check. Follow the equipment manufacturer's procedure and use a suitable calibrated reference instrument.
- Validate process response. Test representative setpoint changes and confirm that the measured flow settles within the required process tolerance.
For troubleshooting, first check gas supply pressure, downstream restrictions, electrical rails, signal wiring, and gas calibration. Unexpected flow readings can result from an incorrect gas factor or an unsuitable pressure differential, not necessarily a failed controller.
07 | Replacement and Selection Considerations
The FC-R7700 is described as compatible with VCR, VCO, and Swagelok-style connection options and as suitable for replacement of selected products from other brands. However, connection style alone does not establish drop-in compatibility.
- Match the full-scale flow range and gas calibration.
- Check the process gas against the wetted materials and elastomer seal.
- Verify inlet pressure and available differential pressure.
- Confirm port size, fitting type, orientation, and port-to-port dimensions.
- Compare the analog signal range, connector, pinout, and supply requirements.
- Confirm normally-open or normally-closed valve action.
For cross-brand replacement, compare the complete mechanical and electrical interface before removing the existing unit. A similar flow range does not guarantee equivalent calibration or control behavior.
08 | Supply, Packaging and Warranty
- Product Condition: New & Original in Factory Packing
- Factory Warranty: 12 Months
- Shipping Options: FedEx, UPS, and DHL
- Documentation: Model and configuration confirmation available upon request.
Contact our sales team with the required flow range, process gas, connection type, and valve action. This information helps confirm the correct FC-R7700 configuration before shipment.
09 | Global PLC Spare HUB – Engineering Insight
When selecting the FC-R7700, engineers should evaluate the minimum controllable flow rather than relying only on the maximum flow rating. Its 2–100% FS control range gives a nominal lower control boundary of 0.2 sccm for a 10 sccm model, or 0.1 slm for a 5 slm model.
Accuracy is specified as a percentage of full scale, not of the instantaneous reading. For example, a 5 slm configuration with ±1% FS accuracy has a stated accuracy band of ±0.05 slm. This distinction is important when the process operates near the lower end of the range.
The elastomer seal is another key selection factor. Confirm the exact seal compound and gas compatibility, especially for oxygen or specialty process applications. For replacement projects, verify the analog interface, pressure differential, fitting geometry, and valve fail position before installation.
10 | Frequently Asked Questions
Q1. How should I choose between a 10 sccm and a 5 slm full-scale model?
Start with the normal process flow, then check peak demand and minimum operating flow. Avoid choosing a much larger range than necessary because the usable control span and absolute full-scale accuracy may affect low-flow process control.
Q2. Why can the indicated flow differ from the actual process flow after changing gases?
Mass flow controllers rely on gas-specific calibration. A controller calibrated for nitrogen may not report accurate flow for argon or oxygen without the correct gas calibration. Confirm the gas configuration before commissioning.
Q3. Can the FC-R7700 replace a different manufacturer's analog MFC without changing the control system?
Not automatically. Compare command and feedback scaling, connector pinout, supply rails, full-scale range, gas calibration, and valve action. Mechanical fitting compatibility alone is insufficient for a reliable replacement.
Q4. What should I investigate if the controller cannot reach its flow setpoint?
Check the differential pressure across the unit first. Then inspect upstream filters, downstream restrictions, gas supply capacity, signal scaling, and calibration. A pressure drop outside the specified operating window can limit achievable flow.
Q5. When should I select normally-open instead of normally-closed valve action?
Base the choice on the process safety design and the required gas behavior after loss of electrical power. Confirm the equipment's shutdown philosophy and the actual valve configuration before ordering. Do not infer fail position from the model family alone.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.