SEC-8470F HORIBA STEC High Temperature Mass Flow Controller
Manufacturer: HORIBA
Product No.: SEC-8470F
Condition: In stock
Product Type: Mass Flow Controller
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
HORIBA STEC SEC-8470F | SEC-8000F High Temperature Digital Mass Flow Controller
The SEC-8470F is a high-temperature digital mass flow controller from the HORIBA STEC SEC-8000F Series. It regulates high-flow process gases in semiconductor manufacturing equipment.
Unlike standard unheated mass flow controllers, this model incorporates a heated sensor section. The heating function helps manage gases that may condense or change behavior at lower temperatures.
The controller supports a nitrogen-equivalent full-scale flow rate of 150 SLM. Its sensor temperature options cover 80–120°C, depending on the selected configuration.
The unit combines a piezoelectric control valve, electropolished SUS316L wetted surfaces, and metal seals. Its electrical interfaces support analog control and RS-485 F-Net communication.
These characteristics make the SEC-8470F suitable for high-flow gas delivery systems. Typical installations include large MOCVD reactors and heated bulk gas lines.
01 | Product Architecture at a Glance
| Manufacturer | HORIBA STEC |
| Model | SEC-8470F |
| Product Series | SEC-8000F |
| Series Classification | High Temperature Digital |
| Product Type | Heated Mass Flow Controller (MFC) |
| Full-Scale Flow | 150 SLM, N2 equivalent |
| Sensor Heating | Yes |
| Heating Options | HL: 80–100°C; HM: 100–120°C |
| Control Valve | Piezoelectric actuator |
| Valve Default State | Normally open when power is off |
| Communication | Analog and RS-485 F-Net |
02 | High-Flow Performance & Control Accuracy
The SEC-8470F provides a 150 SLM full-scale flow capacity. Its control range covers 2% to 100% of full scale.
| Performance Parameter | Specification |
| Full-Scale Flow Rate | 150 SLM |
| Reference Gas | Nitrogen (N2) equivalent |
| Control Range | 2%–100% FS |
| Turndown Ratio | 50:1 |
| Accuracy Above 30% FS | ±1.0% of setpoint |
| Accuracy at or Below 30% FS | ±0.3% FS |
| Repeatability | ±0.3% FS |
| Linearity | ±0.5% FS |
| Response Time | ≤1 second, T98 |
Engineering Interpretation
- High-Flow Capacity: The 150 SLM rating supports high-volume process gas delivery.
- Low-Setpoint Accuracy: The specification changes at the 30% FS threshold.
- Repeatability: ±0.3% FS describes consistency across repeated control operations.
- Linearity: ±0.5% FS describes deviation from the specified linear flow relationship.
- Dynamic Response: T98 ≤1 second specifies the response performance.
- Control Range: The 2%–100% FS range provides a 50:1 turndown ratio.
Practical Selection Example: At 150 SLM full scale, 30% FS equals 45 SLM. The low-setpoint accuracy specification applies at or below this threshold.
Do not confuse percentage of setpoint with percentage of full scale. These accuracy references use different calculation bases.
03 | Thermal Management for Process Gas Delivery
The defining feature of the SEC-8470F is its heated sensor configuration. It supports applications involving corrosive or condensable process gases.
| Thermal Section | Temperature Specification |
| Sensor Section – HL Type | 80–100°C |
| Sensor Section – HM Type | 100–120°C |
| Valve Section | 5–45°C |
| Heating Configuration | Heated sensor section |
Why Sensor Heating Matters
- Helps maintain the sensor above the condensation temperature of compatible process gases.
- Reduces the risk of condensation inside the heated measurement section.
- Supports stable measurement conditions for suitable high-temperature gas applications.
- Provides different heating ranges for different process requirements.
Important Configuration Note: The sensor and valve sections have different temperature limits. The valve section must remain within 5–45°C.
Do not assume the entire controller operates at 80–120°C. Verify the selected HL or HM configuration before installation.
04 | Process Wetted Materials & Gas Compatibility
Material selection is important when handling corrosive, reactive, or condensable gases. The supplied construction specification identifies electropolished SUS316L stainless steel and metal seals.
| Wetted Body Material | SUS316L stainless steel |
| Internal Surface Finish | Electropolished, standard |
| Seal Material | Metal |
| Leak Integrity | ≤5 × 10⁻¹² Pa·m³/s (He) |
| Gas Application | High-temperature process gases |
| Typical Gas Conditions | Corrosive or condensable gases requiring heating |
Material Selection Considerations
- Electropolished surfaces support clean process gas contact.
- SUS316L provides a stainless steel wetted construction.
- Metal seals avoid reliance on standard elastomer sealing materials.
- Helium leak integrity supports demanding gas containment requirements.
Engineering Warning: SUS316L and metal seals do not guarantee compatibility with every corrosive gas. Confirm chemical compatibility, gas purity requirements, and process temperature before selection.
05 | Pressure Envelope & Gas Line Design
Correct pressure conditions are essential for stable high-flow regulation. The following values define the supplied pressure specifications.
| Pressure Parameter | Specification |
| Operating Differential Pressure | 50–300 kPa(d) |
| Maximum Operating Pressure | 300 kPa(d) |
| Pressure Resistance | 1000 kPa(G) |
Pressure Design Notes
- Maintain the specified differential pressure during normal operation.
- Check upstream supply pressure under actual flow conditions.
- Evaluate downstream backpressure and piping restrictions.
- Keep operating pressure within the manufacturer's permitted limits.
- Do not use the pressure resistance rating as a continuous operating limit.
The supplied pressure data uses different reference notations. Confirm the exact pressure definitions and test conditions against the manufacturer documentation before final engineering approval.
06 | Electrical Interface & Control Integration
The SEC-8000F Series supports analog process control and digital communication through its RS-485 F-Net interface.
Analog Interface
| Setpoint Signal | 0.1–5 VDC |
| Flow Output Signal | 0–5 VDC |
Digital Communication
| Communication Protocol | RS-485 F-Net |
| Communication Speed | 38,400 bps |
| Connector Interface | D-Sub 9-pin and RJ-45 |
Power Supply Requirements
| Positive Supply | +15 VDC ±5%, 150 mA |
| Negative Supply | -15 VDC ±5%, 150 mA |
Integration Considerations
- Verify the analog setpoint range before connecting the equipment controller.
- Confirm the output signal scaling within the host control system.
- Check RS-485 wiring and communication parameters.
- Confirm the F-Net protocol implementation and device compatibility.
- Verify connector pin assignments against the applicable wiring documentation.
- Check both positive and negative supply rails during commissioning.
Important: RS-485 describes the electrical communication interface. F-Net defines the specified communication protocol. Do not assume generic Modbus RTU compatibility.
07 | Mechanical Connection & Installation
The SEC-8470F uses a 1/2-inch VCR connection for high-flow gas line integration.
Installation Checklist
- Confirm the 1/2-inch VCR connection specification.
- Check the gas line cleanliness before installation.
- Use compatible metal gasket and fitting components.
- Verify the installation direction and flow path.
- Check mounting arrangements and maintenance clearance.
- Confirm the sensor heating option before energization.
- Maintain the valve section within its specified temperature range.
- Inspect all gas connections for leakage.
- Verify analog and RS-485 wiring before process startup.
Use suitable VCR installation procedures and manufacturer-approved sealing components. Avoid contamination during connection assembly.
Replacement Advice: Check the fitting size and center distance before replacing an existing controller. A matching flow rating does not guarantee mechanical interchangeability.
08 | Process Applications & Equipment Integration
The HORIBA STEC SEC-8470F is intended for high-flow gas delivery where sensor heating is necessary.
| Application | Engineering Requirement |
| Large MOCVD Reactors | High-capacity process gas regulation. |
| Heated Bulk Gas Lines | Temperature-controlled gas measurement conditions. |
| Corrosive Gas Delivery | Compatible wetted materials and metal sealing. |
| Condensable Gas Systems | Heated sensor operation to manage condensation risk. |
| Semiconductor Gas Panels | High-flow control with analog and digital interfaces. |
For these applications, engineers should evaluate gas chemistry, flow demand, pressure stability, and thermal conditions together.
09 | Compliance & Product Standards
- RoHS: RoHS compliant.
- Industry Standards: SEMI standards compliance.
Confirm the applicable SEMI standard numbers and supporting declarations against the exact product documentation. Do not assume additional hazardous-area or safety certifications.
10 | Configuration & Replacement Verification
Before ordering the SEC-8470F, confirm the complete process configuration. The heating range, gas compatibility, and electrical interface affect replacement suitability.
Pre-Purchase Verification
- Model: SEC-8470F.
- Series: SEC-8000F High Temperature Digital.
- Flow Capacity: 150 SLM, N2 equivalent.
- Heating Type: HL or HM.
- Gas Compatibility: Confirm the actual process gas.
- Sealing: Verify metal seal configuration.
- Connection: Confirm 1/2-inch VCR fittings.
- Communication: Verify analog and RS-485 F-Net requirements.
- Power: Confirm dual ±15 VDC supply availability.
- Valve Behavior: Confirm normally open operation when power is off.
- Pressure: Check differential and maximum operating conditions.
Critical Selection Point: Do not substitute an unheated MFC solely because it has the same nominal flow capacity. Heating capability is a functional requirement for the specified process conditions.
11 | Five Professional Engineering FAQs
Q1: How should engineers choose between the HL and HM heating configurations?
The HL configuration covers 80–100°C. The HM configuration covers 100–120°C. Selection depends on the process gas temperature requirements and condensation characteristics. Engineers should evaluate the gas vapor behavior, line temperature, and process operating conditions before choosing either option.
Q2: Why is the valve section limited to 5–45°C when the sensor reaches 120°C?
The sensor and valve sections have separate thermal operating limits. The heated design targets the measurement section rather than the entire assembly. Excessive valve-section temperature may affect its operating conditions. Maintain suitable thermal separation and cabinet ventilation during installation.
Q3: What does normally open when power is off mean for gas system safety?
The piezoelectric valve has a normally open default state without power. Gas flow may therefore remain possible after power loss. Engineers must evaluate the upstream isolation valve and system shutdown sequence. Never rely on this controller alone for emergency gas isolation.
Q4: How can engineers diagnose unstable flow after replacing the controller?
First, verify the selected heating configuration and allow the sensor to reach its specified operating temperature. Then check the gas calibration, differential pressure, and setpoint scaling. Inspect the VCR connections and electrical supply rails. Finally, compare the analog output with the host controller reading.
Q5: Can the SEC-8470F operate through RS-485 without using its analog interface?
The supplied specifications identify both analog signals and RS-485 F-Net communication. However, the available operating modes and command functions require confirmation from the communication manual. Check the host controller's F-Net support, device configuration, and wiring requirements before designing a digital-only connection.
12 | Ordering Information & Technical Support
Looking for the HORIBA STEC SEC-8470F High Temperature Mass Flow Controller?
| Brand | HORIBA STEC |
| Model | SEC-8470F |
| Series | SEC-8000F |
| Product Type | Heated Digital Mass Flow Controller |
| Flow Capacity | 150 SLM |
| Heating Range | 80–120°C, configuration dependent |
| Communication | Analog / RS-485 F-Net |
| Warranty | 12 months, subject to sales terms |
| Pre-Shipment Inspection | Available before delivery |
| Shipping Options | DHL, FedEx, UPS, and other supported carriers |
Contact our sales team for current pricing, availability, and delivery information. Include your process gas, heating option, and connection requirements when requesting a quotation.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.