SEC-8440F HORIBA STEC Heated Mass Flow Controller SEC-8000F Series
Manufacturer: HORIBA
Product No.: SEC-8440F
Condition: In stock
Product Type: Mass Flow Controller
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
SEC-8440F | HORIBA STEC | SEC-8000F High Temperature Digital Mass Flow Controller
The HORIBA STEC SEC-8440F is a high-temperature digital mass flow controller designed for demanding semiconductor gas delivery systems. Its heated sensor section helps maintain stable measurement conditions when process gases tend to condense.
Within the SEC-8000F Series, this model combines thermal management, precision flow control, and digital communication. It supports applications involving corrosive or condensable gases, including metalorganic precursors and titanium tetrachloride (TiCl4).
Its electropolished SUS316L wetted surfaces and metal seals support demanding gas-handling requirements. A piezoelectric control valve provides normally open operation when power is removed.
01 | Engineering Configuration at a Glance
| Manufacturer | HORIBA STEC |
| Model | SEC-8440F |
| Product Series | SEC-8000F High Temperature Digital |
| Product Type | Heated Digital Mass Flow Controller (MFC) |
| Sensor Configuration | Heated sensor section, HL or HM type |
| Control Valve | Piezoelectric actuator, normally open when power is off |
| Gas Connections | 1/4-inch VCR |
| Communication | Analog interface and RS-485 F-Net |
| Typical Applications | MOCVD, ALD, and heated corrosive gas delivery |
02 | Flow Performance and Measurement Characteristics
The available full-scale ranges cover low-flow and higher-flow process configurations. Select the range according to the required gas flow and operating conditions.
| Full-Scale Flow Options | 5, 10, 20, 30, 50, 100, 200, 300, 500 SCCM; 1 and 2 SLM |
| Reference Gas | N2 equivalent |
| Accuracy | ±1.0% S.P. above 30% FS; ±0.3% FS at or below 30% FS |
| Repeatability | ±0.2% FS |
| Response Time | ≤1 second (T98) |
| Control Range | 2–100% FS |
| Linearity | ±0.5% FS |
Engineering note: Accuracy uses two different reference bases. Above 30% FS, it references the setpoint. At or below 30% FS, it references full scale. Do not treat these values as interchangeable during measurement uncertainty calculations.
03 | Thermal Management and Gas-Wetted Construction
Condensation can affect flow measurement and restrict internal gas passages. The heated sensor section helps keep process gas above its condensation threshold.
| HL Heated Type | 80–100°C sensor section |
| HM Heated Type | 100–120°C sensor section |
| Valve Section | 5–45°C ambient operating range |
| Wetted Material | SUS316L stainless steel |
| Surface Finish | Electropolished inner surface as standard |
| Seal Construction | Metal seals |
| Leak Integrity | ≤5 × 10⁻¹² Pa·m³/s (He) |
The sensor heating configuration requires careful coordination with the process gas temperature profile. The heated section does not automatically guarantee that the complete upstream and downstream gas path remains condensation-free.
04 | Electrical Interface and Control Architecture
| Analog Setpoint | 0.1–5 VDC |
| Analog Output | 0–5 VDC |
| Digital Communication | RS-485, F-Net protocol |
| Communication Speed | 38,400 bps |
| Connectors | D-Sub 9-pin and RJ-45 |
| Positive Supply | +15 VDC ±5%, 150 mA |
| Negative Supply | −15 VDC ±5%, 150 mA |
| Actuator | Piezoelectric valve |
| Power-Off Valve State | Normally open |
For analog integration, confirm the controller's input and output scaling before commissioning. For digital integration, verify F-Net compatibility, RS-485 wiring, connector pin assignments, and host communication settings.
05 | Process Integration: Where SEC-8440F Adds Value
- MOCVD gas delivery: Supports controlled delivery of temperature-sensitive precursor gases.
- ALD process systems: Helps manage gas flow where condensation can affect measurement stability.
- Metalorganic precursors: Heated sensing supports applications involving condensable process materials.
- TiCl4 delivery: Provides a heated measurement configuration for suitable process gas systems.
- Corrosive gas handling: SUS316L wetted surfaces and metal seals support compatible gas-service configurations.
Always verify material compatibility against the actual gas composition, concentration, temperature, and pressure. A heated MFC does not replace the need for compatible upstream regulators, tubing, valves, and exhaust arrangements.
06 | Installation and Commissioning Recommendations
- Confirm the gas configuration. Match the selected full-scale range to the process gas and required flow.
- Check the heated option. Verify whether the application requires HL or HM temperature settings.
- Inspect the VCR connections. Use compatible fittings and follow the equipment manufacturer's sealing procedure.
- Verify the gas path. Review upstream and downstream temperatures to identify potential condensation points.
- Check the power rails. Confirm both +15 VDC and −15 VDC supplies before applying the setpoint.
- Validate the control interface. Confirm analog scaling or RS-485 F-Net communication before process operation.
- Perform a controlled leak test. Follow the facility's approved procedure for the actual process gas.
07 | Troubleshooting Insights for Process Engineers
- Unexpected flow drift: Check gas temperature, pressure stability, and the possibility of condensation in unheated piping.
- Slow flow response: Inspect gas supply stability, valve operating conditions, and upstream restrictions.
- Communication failure: Check RS-485 polarity, wiring continuity, host settings, and F-Net compatibility.
- Incorrect analog readings: Verify signal grounding, scaling, and the difference between setpoint and output ranges.
- Abnormal valve behavior: Remember that the valve is normally open when power is off. Include this state in shutdown and safety reviews.
Do not expose the heated sensor section to process gas until the required thermal conditions are established. Follow the equipment manufacturer's approved warm-up and startup procedure.
08 | Compliance and Product Handling
- RoHS compliant.
- Designed with reference to applicable SEMI requirements.
- Helium leak integrity specification: ≤5 × 10⁻¹² Pa·m³/s.
- Use appropriate handling procedures for corrosive, toxic, or condensable gases.
- Confirm the exact certification scope and applicable SEMI requirements against the supplied product documentation.
09 | Frequently Asked Questions
Q1: How should engineers select the correct full-scale range for a new process recipe?
Choose a range that accommodates the maximum required flow while preserving useful control resolution. Avoid selecting an unnecessarily large range, especially for low-flow precursor dosing. Confirm the actual gas conversion and recipe operating points before final selection.
Q2: Can this controller be installed directly beside an unheated gas line?
Not without evaluating the complete thermal profile. A heated sensor section cannot prevent condensation in a colder upstream fitting or downstream pipe. Review every potential cold spot between the gas source and process chamber.
Q3: What should technicians check when measured flow differs from an external reference instrument?
First, verify gas identity, calibration basis, reference conditions, and pressure stability. Then check the reference instrument's uncertainty and installation position. Comparing different gas calibration factors can produce misleading conclusions.
Q4: Does the normally open valve state provide process isolation during a power failure?
No. Normally open operation means the valve opens when power is removed. Engineers must assess the resulting gas flow path and provide independent isolation where the process safety design requires it.
Q5: What information should buyers provide when requesting a replacement or equivalent unit?
Provide the complete model number, full-scale range, HL or HM heating configuration, gas type, connection specification, and electrical interface. Include the existing system's communication requirements and installation constraints. These details help prevent configuration mismatches.
10 | Supply and Ordering Information
HORIBA STEC SEC-8440F is a specialized heated digital mass flow controller for demanding semiconductor gas applications.
- Brand: HORIBA STEC
- Model: SEC-8440F
- Series: SEC-8000F High Temperature Digital
- Product Type: Heated Digital Mass Flow Controller
- Configuration Confirmation: Please specify flow range, gas type, and heating option.
Contact our team with your model and application requirements. We can help confirm the product configuration, interface, and availability before ordering.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.