XNX-AMSV-NHIF1 Honeywell Universal Gas Transmitter IR Propane
Manufacturer: Honeywell
Product No.: XNX-AMSV-NHIF1
Condition: In stock
Product Type: Universal Gas Transmitter
Product Origin: USA
Payment: T/T, Western Union
Weight: 6800g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Overview
The XNX-AMSV-NHIF1 Honeywell Universal Transmitter delivers continuous optical gas detection engineered for harsh hydrocarbon processing environments. Housed in a painted 316 stainless steel flameproof enclosure, this unit comes pre-configured with an integrated MPD infrared sensor cartridge calibrated for 0–100% LEL Propane detection. Operating over a 4-20mA analog current loop with HART digital protocol, it includes a dedicated local external HART interface port for fast field commissioning and diagnostic access.
Configuration Architecture Breakdown
-
Honeywell XNX Series Platform
- Hazardous Area Approval [A]: ATEX / IECEx / INMETRO Certified
- Conduit Entry Type [M]: 5 x M25 Metric Cable Entries
- Housing Material [S]: Marine-Grade Painted 316 Stainless Steel (6.8 kg)
- Input Personality [V]: Millivolt (mV) / MPD Cartridge Interface Board
- Internal Hardware Option [N]: Base Configuration (No Internal Relays / Bus Modules)
- Local Service Interface [H]: External Intrinsically Safe Local HART Access Port
- Sensor Cartridge [IF1]: Integrated MPD Optical Infrared Sensor (0–100% LEL Propane)
Technical Specifications & Operating Boundaries
| Engineering Parameter | Field Specification Detail |
|---|---|
| Manufacturer Name | Honeywell |
| Full Model Number | XNX-AMSV-NHIF1 |
| Product Series | Honeywell XNX Universal Gas Transmitter |
| Target Gas Calibration | Propane (C3H8) Hydrocarbon Gas (0–100% LEL Range) |
| Sensing Technology | MPD Dual-Beam Optical Infrared (IR) Sensor Cartridge |
| Primary Output Signal | 4-20mA Analog Signal with Integrated HART Protocol |
| Local Diagnostic Access | Bottom-Mounted External Local HART Interface Socket |
| Ingress Protection Rating | IP66 Weatherproof Seal (NEMA 4X equivalent) |
| Operating Temperature | -40°C to +65°C (-40°F to +149°F) Base Unit Limits |
| Ambient Humidity Window | 0 to 99% RH Non-Condensing Operating Range |
| Operating Air Pressure | 80 kPa to 120 kPa Absolute Pressure Window |
| Unit Net Weight | 6.8 Kg (Solid 316 Stainless Steel Casing) |
Compatible Hardware & Operational Deployments
-
Compatible System Hardware:
- Honeywell Experion PKS, Safety Manager, and System 57 Control Panels.
- Third-party PLCs, DCS architectures, and Safety Instrumented Systems (SIS).
- Intrinsically safe handheld HART field communicators and Asset Management Software (AMS).
-
Target Industrial Applications:
- Liquefied Petroleum Gas (LPG) bottling plants, bulk storage spheres, and distribution terminals.
- Offshore oil drilling platforms, FPSOs, and coastal LNG regasification facilities.
- Petrochemical cracking units, hydrocarbon pump houses, and gas turbine skids.
Diagnostic & Predictive Self-Monitoring Capabilities
The XNX-AMSV-NHIF1 Honeywell transmitter continuously monitors optical path clarity, IR lamp output, baseline signal drift, and internal microcontroller health. If severe window obscuration or internal hardware degradation occurs, the device immediately drops its analog loop output to dedicated fault currents (≤2.0mA), broadcasting precise diagnostic codes over HART. This allows instrumentation teams to perform proactive cleaning or cell replacements before false trips disrupt production loops.
Model Selection Comparison & Engineering Recommendation
Selecting the correct digital communication option and target gas calibration ensures seamless control system integration. Below is an engineering comparison between the XNX-AMSV-NHIF1 and the alternative XNX-AMSV-FNIV1 configuration:
| Selection Specification | XNX-AMSV-NHIF1 | XNX-AMSV-FNIV1 |
|---|---|---|
| Primary Gas Calibration | Propane (0–100% LEL Hydrocarbon IR) | Methane (0–100% LEL Hydrocarbon IR Vol) |
| Digital Bus Protocol | Standard HART over 4-20mA (No Bus Module) | FOUNDATION Fieldbus H1 Communication Board |
| Local Diagnostic Port | Integrated External Local HART Port Included | Standard Housing (Internal Terminal Access) |
| Enclosure Construction | Painted 316 Stainless Steel (6.8 kg) | Painted 316 Stainless Steel (6.8 kg) |
| Hazardous Area Approval | ATEX / IECEx / INMETRO Certified | ATEX / IECEx Hazardous Area Certified |
Engineering Advice: Specify the XNX-AMSV-NHIF1 for facilities monitoring heavier hydrocarbon vapors (such as Propane or LPG) that transmit signals over point-to-point 4-20mA analog loops and require convenient local handheld HART access. Choose the XNX-AMSV-FNIV1 when measuring Methane in plants utilizing digital FOUNDATION Fieldbus H1 multi-drop networks.
Global PLC Spare HUB's Insight
In propane storage farm installations, catalytic bead sensors often suffer from poison accumulation due to atmospheric contaminants, leading to frequent zero shifts. Upgrading to the XNX-AMSV-NHIF1 Honeywell infrared transmitter completely eliminates sensor poisoning risks because optical IR technology does not rely on chemical reactions. On a recent tank farm overhaul, deploying this optical Honeywell XNX model reduced field routine test intervals from quarterly to annually, while the external local HART port enabled technicians to complete bump tests in minutes without opening the flameproof housing.
Warranty, Logistics & Shipping Terms
- Product Condition: 100% Brand New Original Factory Supply
- Warranty Guarantee: Standard 12-Month Quality Warranty from dispatch date
- Order Processing Time: Fast handling, shipping within 24 to 48 hours post-payment
- Global Express Shipping: Door-to-door courier service via FedEx, UPS, and DHL Express
Engineering Selection & Operational FAQ
What is the primary advantage of infrared gas sensing over traditional catalytic bead detectors?
Infrared optical sensors do not require oxygen to operate, cannot be poisoned by silicones or sulfides, and handle continuous exposure to high gas concentrations without element burnout.
Can the IF1 Propane IR sensor cartridge detect Methane gas accurately?
While the IF1 sensor responds to various hydrocarbons, its internal optical filter and cross-calibration curve are optimized for Propane (C3H8). For dedicated Methane monitoring, specify the IV1 sensor variant.
How does the local HART port save maintenance time in classified areas?
The external intrinsically safe HART port allows field operators to plug in a communicator directly under power, eliminating the requirement to obtain a hot-work permit or unbolt the heavy 316SS cover.
What cable gland configuration is recommended for the M25 entry threads?
Use certified explosion-proof double-seal cable glands rated Ex d / Ex tb with IP66 seals to maintain compliance and prevent ingress of moisture or corrosive coastal air.
Is an oxygen supply necessary for this transmitter to detect flammable gases?
No. Because the optical MPD IR sensor measures gas absorption of specific infrared light wavelengths, it operates accurately in inert gas atmospheres or total oxygen-deficient environments.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.