Home 626BRETAF MKS Instruments Capacitance Diaphragm Pressure Transducer

626BRETAF MKS Instruments Capacitance Diaphragm Pressure Transducer

  • Manufacturer: MKS Instruments

  • Product No.: 626BRETAF

  • Condition: In stock

  • Product Type: Absolute Capacitance Manometer

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Product Overview | MKS Baratron 626B Pressure Measurement

MKS Instruments 626BRETAF is a precision capacitance diaphragm pressure transducer from the Baratron® 626B Series. It measures absolute pressure through a capacitive sensing structure. Its measurement principle operates independently of gas composition.

This configuration provides a 0.25 Torr full-scale range and ±0.50% of reading accuracy. It uses a 1/2-inch tubulation connection and a 15-pin male D-subminiature electrical connector.

The sensor delivers a linear 0–10 VDC analog output for compatible pressure monitoring and control systems. Its Inconel® and Incoloy® wetted materials support demanding vacuum process environments.

The 626BRETAF suits vacuum equipment, semiconductor processing systems, and precision pressure monitoring applications. Its fast response and low-pressure measurement capability support process control and equipment diagnostics.

01 | Model Identification and Configuration Breakdown

The model code identifies the sensor family, measurement range, connection configuration, and accuracy grade. The following breakdown follows the supplied 626B configuration information.

Code Segment Configuration Engineering Meaning
626B Product Series Baratron® 626B ambient-temperature absolute pressure transducer
RET Full-Scale Range 0.25 Torr
A Fitting Configuration 1/2-inch (12.7 mm) OD tubulation
F Accuracy Code ±0.50% of reading

Complete Model: 626BRETAF

Configuration Summary:

  • Measurement Family: Baratron® capacitance diaphragm pressure measurement.
  • Pressure Reference: Absolute pressure.
  • Pressure Range: 0.25 Torr full scale.
  • Process Connection: 1/2-inch OD tubulation.
  • Accuracy Grade: ±0.50% of reading.
  • Electrical Interface: 15-pin male D-sub connector.

This model belongs to the ambient-temperature 626B configuration. Do not confuse it with heated Baratron transducers designed for elevated-temperature operation.

02 | Core Technical Specifications

Specification Technical Details
Manufacturer MKS Instruments
Product Model 626BRETAF
Product Series Baratron® 626B
Product Type Capacitance Diaphragm Gauge / Absolute Pressure Transducer
Measurement Principle Capacitance diaphragm sensing
Pressure Reference Absolute
Full-Scale Range 0.25 Torr
Accuracy ±0.50% of reading
Usable Measurement Range 1 × 10⁻⁴ of full scale
Suggested Minimum Pressure for Reading 1 × 10⁻⁴ Torr
Suggested Minimum Pressure for Control 1 × 10⁻³ Torr
Analog Output 0 to +10 VDC
Output Load ≥10 kΩ
Power Supply ±15 VDC (±5%)
Supply Current 35 mA
Electrical Connector 15-pin male D-subminiature
Process Connection 1/2-inch (12.7 mm) OD tubulation
Wetted Materials Inconel® 600 and Incoloy®
Operating Temperature 15°C to 40°C
Overpressure Limit 45 psia (310 kPa), without damage
Warm-Up Time 15 minutes
Time Constant Less than 20 ms
Internal Volume, Px Side 6.3 cc

03 | Measurement Principle and Performance

The Baratron® 626B uses a thin diaphragm as its pressure-sensitive element. Pressure changes cause diaphragm displacement. The resulting capacitance variation produces an electrical measurement signal.

Unlike thermal conductivity vacuum gauges, capacitance diaphragm technology does not depend on the thermal properties of the measured gas. This characteristic supports pressure measurement across different process gas compositions.

Measurement Characteristics:

  • Absolute Pressure Measurement: Measures pressure relative to an internal reference vacuum.
  • Gas Independence: The measurement principle does not rely on gas thermal conductivity.
  • Linear Output: Provides a 0–10 VDC signal proportional to pressure across the specified range.
  • Fast Response: Time constant remains below 20 milliseconds.
  • Low-Pressure Capability: Supports readings down to the specified minimum pressure.

Accuracy Interpretation: The ±0.50% reading specification includes non-linearity, hysteresis, and non-repeatability. This accuracy code applies to the specified 0.10 Torr and 0.25 Torr ranges.

04 | Electrical Interface and Signal Conditioning

The 626BRETAF requires a bipolar power supply and provides a single-ended positive analog output. Proper grounding and shielding are essential for stable low-pressure measurements.

Electrical Item Requirement
Positive Supply +15 VDC ±5%
Negative Supply -15 VDC ±5%
Supply Current 35 mA
Signal Output 0–10 VDC
Minimum Output Load 10 kΩ
Electrical Connector 15-pin male D-subminiature
Cable Shielding Overall metal-braided shield
Shield Grounding Ground at both ends

Wiring Recommendation: Use a properly shielded cable with an overall metal braid. Ground the shield at both ends according to the manufacturer's installation instructions.

Keep signal wiring away from high-current switching conductors where practical. Verify the controller input impedance before connecting the analog output.

Important: The supplied specifications do not establish the individual 15-pin connector pin assignments. Obtain the correct MKS wiring diagram before terminating the cable.

05 | Temperature Characteristics and Overpressure Protection

The ambient-temperature configuration operates within a specified range of 15°C to 40°C. Temperature coefficients determine the expected measurement variation as ambient conditions change.

Parameter Specification
Operating Temperature 15°C to 40°C
Zero Temperature Coefficient 0.005% F.S./°C
Span Temperature Coefficient 0.04% of reading/°C
Maximum Overpressure 45 psia (310 kPa)
Warm-Up Period 15 minutes

Overpressure Consideration: The 45 psia limit specifies the maximum pressure without damage. It does not represent the normal measurement range.

Avoid sudden pressure surges during pump-down and process venting. Use suitable isolation and pressure-control arrangements when the system can experience abnormal pressure conditions.

06 | Process Connection and Wetted Materials

The model suffix identifies a 1/2-inch OD tubulation connection. This configuration supports compatible vacuum tubing and process connection arrangements.

Mechanical Item Configuration
Fitting Code A
Connection Type OD tubulation
Nominal Outside Diameter 12.7 mm (1/2 inch)
Wetted Material Inconel® 600 and Incoloy®
Alternative Fitting Materials Some optional fittings use 300-series stainless steel
Pressure-Side Internal Volume 6.3 cc

Material Selection: Inconel and Incoloy provide corrosion-resistant metallic construction. Confirm chemical compatibility with the actual process gas and cleaning chemicals before installation.

07 | Installation and Commissioning Procedure

Correct installation helps preserve measurement accuracy and signal stability. Follow these engineering checks before introducing the sensor into the vacuum system.

  • Mechanical Connection: Confirm the 1/2-inch OD tubulation matches the process tubing.
  • Installation Environment: Maintain ambient temperature between 15°C and 40°C.
  • Power Supply: Provide stable +15 VDC and -15 VDC rails within ±5%.
  • Signal Connection: Connect the 0–10 VDC output to a compatible analog input.
  • Input Impedance: Maintain a receiving load of at least 10 kΩ.
  • Cable Shielding: Use an overall metal-braided shield.
  • Grounding: Ground the cable shield at both ends as specified.
  • Warm-Up: Allow at least 15 minutes before evaluating measurement performance.
  • Pressure Verification: Compare the sensor output with a suitable reference instrument.

Commissioning Tip: Do not evaluate the final zero reading immediately after power-up. Allow the specified warm-up period and confirm stable ambient conditions first.

08 | Maintenance and Measurement Stability

Routine inspection helps identify installation-related measurement errors before they affect process control. Focus on the electrical supply, cable shielding, process connection, and operating environment.

Inspection Item Recommended Action
Power Supply Measure both positive and negative supply rails.
Analog Output Verify output voltage against the applied reference pressure.
Signal Cable Inspect braid continuity and grounding at both ends.
Process Tubing Check connection integrity and possible leakage.
Temperature Confirm operation within the specified ambient range.
Warm-Up Allow 15 minutes after power-up before measurement evaluation.
Zero Stability Compare readings under repeatable reference conditions.

Maintenance Recommendation: Avoid unnecessary mechanical handling of the pressure-sensitive assembly. Investigate zero shifts before adjusting system scaling or replacing the controller input module.

09 | System Compatibility and Application Integration

The MKS 626BRETAF supports vacuum measurement systems that accept bipolar power and a 0–10 VDC analog signal.

  • Vacuum Controllers: Connect to compatible voltage-input pressure controllers.
  • PLC Systems: Use an analog input channel with a suitable 0–10 VDC range.
  • DCS Systems: Integrate through a compatible voltage signal conditioning module.
  • Semiconductor Equipment: Monitor pressure in compatible vacuum process chambers.
  • Vacuum Deposition: Support pressure monitoring in coating and thin-film equipment.
  • Research Systems: Provide absolute pressure feedback for laboratory vacuum equipment.

Scaling Reference: The 0–10 VDC output corresponds to the specified 0–0.25 Torr full-scale range. Confirm the controller's scaling configuration before using the signal for closed-loop control.

Do not connect the voltage output directly to a 4–20 mA input without a suitable signal conversion interface. Verify connector pinout and power requirements before integrating the sensor into an existing system.

10 | Compliance and Environmental Directives

Compliance Item Specification
CE Compliance EMC Directive 2004/108/EC
RoHS Compliance Directive 2002/95/EC

Confirm the applicable documentation and compliance requirements for the equipment installation date and destination market.

11 | Typical Industrial Applications

  • Semiconductor Manufacturing: Monitor absolute pressure in vacuum process equipment.
  • Thin-Film Deposition: Provide pressure feedback for deposition chamber control.
  • Vacuum Coating: Monitor pressure conditions during coating operations.
  • Laboratory Vacuum Systems: Support precise pressure measurement and experimental control.
  • Industrial Vacuum Equipment: Provide analog pressure feedback to automation controllers.
  • Process Development: Monitor low-pressure conditions in controlled experimental environments.

12 | Selection and Replacement Checklist

Engineers should verify the complete configuration before selecting this model for a new installation or replacement project.

Selection Point Required Verification
Model Number 626BRETAF
Pressure Range 0.25 Torr full scale
Accuracy ±0.50% of reading
Pressure Reference Absolute
Fitting 1/2-inch OD tubulation
Electrical Connector 15-pin male D-sub
Power Supply ±15 VDC
Output Signal 0–10 VDC
Operating Temperature 15°C to 40°C

Replacement Warning: Do not select a replacement based only on the 626B series designation. Verify the full suffix, pressure range, fitting, accuracy code, connector, and supply requirements.

13 | Packaging, Warranty and Shipping

  • Product: MKS Instruments 626BRETAF Baratron® Pressure Transducer.
  • Configuration: 0.25 Torr, 1/2-inch OD tubulation, 15-pin male D-sub.
  • Protective Packaging: Suitable packaging for industrial precision instrumentation.
  • Product Documentation: Supplied according to the confirmed order configuration.

Warranty: 12-month warranty.

Shipping Methods: FedEx, UPS, and DHL international delivery services.

Product Condition: New and original factory-supplied equipment.

Ordering Note: Confirm the exact suffix and required accessories before ordering. Cables, controllers, and additional vacuum fittings require separate confirmation.

14 | Technical FAQ and Engineering Selection Advice

Q1: Why should engineers choose a capacitance diaphragm gauge instead of a thermal conductivity vacuum gauge?

A capacitance diaphragm gauge measures pressure through mechanical diaphragm displacement. Its measurement principle does not depend on the thermal conductivity of the process gas. This makes it suitable for applications where gas composition changes during processing. Engineers should still consider pressure range, accuracy, and operating conditions when selecting the technology.

Q2: Can the 626BRETAF measure pressure when the process gas changes from nitrogen to argon?

Yes. The capacitance measurement principle does not require gas-specific thermal conductivity correction. However, process compatibility and the pressure connection must remain suitable for the actual gas. Check material compatibility when handling reactive or corrosive gases.

Q3: What is the practical difference between pressure measurement and pressure control at very low vacuum levels?

Measurement indicates the pressure available for monitoring. Closed-loop control also depends on signal stability, controller resolution, system response, and process dynamics. The suggested minimum pressure is 1 × 10⁻⁴ Torr for reading and 1 × 10⁻³ Torr for control. Engineers should use these limits when defining control strategies.

Q4: Why might a PLC display an unstable pressure value even when the transducer operates correctly?

Check the analog input impedance, grounding arrangement, and cable shielding first. Electrical noise can affect low-level measurement signals. Also verify the bipolar supply rails and controller scaling. A stable pressure reference helps distinguish electrical interference from actual process fluctuations.

Q5: What should be considered when replacing a 626B transducer with a different pressure range?

Check the full-scale range, output scaling, accuracy specification, fitting, and electrical interface. A different range changes the pressure-to-voltage relationship. The controller may require new scaling parameters. Confirm the mechanical connection and calibration requirements before installation.

Precision Vacuum Measurement for Critical Processes

The MKS Instruments 626BRETAF combines Baratron® capacitance diaphragm technology with a 0.25 Torr measurement range and ±0.50% of reading accuracy.

Its 0–10 VDC output, 15-pin D-sub interface, and 1/2-inch tubulation support integration into compatible vacuum measurement systems. The configuration suits applications that require gas-independent absolute pressure monitoring and fast measurement response.

Contact us for a quotation, availability, technical documentation, or replacement verification. Provide your existing model number and system requirements for configuration assistance.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.