Home 728A13TCE2FA MKS Instruments 728A Heated Capacitance Manometer

728A13TCE2FA MKS Instruments 728A Heated Capacitance Manometer

  • Manufacturer: MKS Instruments

  • Product No.: 728A13TCE2FA

  • Condition: In stock

  • Product Type: Absolute Capacitance Manometer

  • Product Origin: DE

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Product Overview | Heated Absolute Pressure Technology

The MKS Instruments 728A13TCE2FA belongs to the MKS 728A Baratron® heated capacitance manometer series. It measures absolute pressure through a precision capacitive diaphragm sensing element.

The instrument maintains its sensor temperature at 100°C. This controlled heating helps reduce process gas condensation and material deposition inside the sensing assembly.

Its 1000 Torr full-scale range supports pressure monitoring in semiconductor manufacturing and industrial vacuum processes. The all-Inconel® wetted construction provides strong resistance to corrosive process gases and chemical by-products.

The specified configuration includes an 8 VCR female fitting and a proportional 0–10 VDC analog output. Its response time is less than 75 ms, supporting dynamic pressure monitoring and process feedback.

01 | Model Configuration & Ordering Code Breakdown

Complete Model: 728A13TCE2FA

Code Segment Configuration Technical Meaning
728A Series Heated absolute Baratron® capacitance manometer, 100°C sensor temperature
13T Pressure Range 1000 Torr full scale
CE Vacuum Fitting 8 VCR female connection
2 Electrical Configuration Standard ±15 VDC supply and 0–10 VDC analog output
F Accuracy Code 0.50% of Reading, subject to configuration confirmation
A Connector Code 9-pin D-sub according to supplied ordering information; verify against original product documentation

Configuration Identification:

  • 728A: Identifies the heated sensor platform.
  • 13T: Defines the 1000 Torr pressure range.
  • CE: Specifies the 8 VCR female vacuum connection.
  • 2: Defines the standard power and analog output configuration.
  • FA: Identifies the stated accuracy and connector configuration.

Ordering Warning: The supplied technical description for 728A13TCE2FB specifies a 15-pin D-sub connector. Do not substitute that connector specification for the requested FA configuration without checking the original MKS ordering documentation.

02 | Technical Data Matrix

Manufacturer MKS Instruments
Product Model 728A13TCE2FA
Product Series 728A Baratron® Series
Product Type Heated Absolute Capacitance Manometer
Instrument Category Pressure Transducer / Vacuum Gauge
Measurement Principle Capacitance diaphragm sensing
Measurement Reference Absolute pressure
Full-Scale Range 1000 Torr
Equivalent Pressure Approximately 133.32 kPa / 1.333 bar
Sensor Temperature 100°C
Measurement Accuracy ±0.50% of Reading, 10–1000 Torr
Response Time Less than 75 ms
Zero Temperature Coefficient 0.010% of Full Scale/°C
Span Temperature Coefficient 0.040% of Full Scale/°C
Ambient Operating Temperature 15°C to +50°C
Overpressure Limit 45 psia or 2 × Full Scale, whichever is greater
Burst Pressure 10 × Full Scale or 90 psi, whichever is greater
Wetted Materials Inconel®
Heating Configuration Temperature controlled at 100°C

03 | Thermal Management & Process Protection

The heated sensing assembly maintains a controlled temperature of 100°C. This design helps minimize condensation and deposition from process gases.

Thermal Performance:

Sensor Temperature 100°C
Ambient Temperature 15°C to +50°C
Zero Temperature Coefficient 0.010% FS/°C
Span Temperature Coefficient 0.040% FS/°C

Engineering Advantages:

  • Maintains a controlled sensing temperature.
  • Helps reduce condensation inside the measurement assembly.
  • Limits process residue accumulation under suitable operating conditions.
  • Supports stable measurement in heated vacuum process environments.
  • Reduces measurement disturbances associated with temperature-sensitive process deposits.

04 | Pressure Measurement & Protection Architecture

The capacitive diaphragm responds to pressure changes. Its movement changes the electrical capacitance within the sensing element.

The electronics convert this capacitance variation into a proportional pressure signal. The absolute measurement reference supports consistent pressure monitoring independent of atmospheric pressure changes.

Measurement Range 1000 Torr Full Scale
Accuracy ±0.50% of Reading
Response Time <75 ms
Overpressure Protection Limit 45 psia or 2 × FS, whichever is greater
Burst Pressure 10 × FS or 90 psi, whichever is greater

Important: Overpressure tolerance and burst pressure describe different limits. Neither value represents a normal operating pressure rating.

05 | Electrical Interface & Signal Output

Power Requirement ±15 VDC
Analog Output 0–10 VDC
Output Type Linear proportional analog signal
Electrical Connector D-subminiature; exact pin count requires FA configuration verification
Connector Information for FB Variant 15-pin Type D, according to supplied FB description

The analog output supports integration with compatible pressure controllers, monitoring instruments, and process automation systems.

Verify the electrical pinout before connecting the instrument. Do not assume that the FA and FB connector arrangements are interchangeable.

06 | Vacuum Connection & Wetted Construction

Vacuum Fitting 8 VCR Female
Fitting Code CE
Wetted Material Inconel® Nickel Alloy
Construction All-metal sensing structure
Sealing Interface Metal face-seal connection

The Inconel® construction provides high corrosion resistance against many process gases and chemical by-products. The 8 VCR female connection supports metal-sealed vacuum installations.

Engineers should verify fitting dimensions, compatible gasket materials, and process chemical compatibility before installation.

07 | Installation & Commissioning Procedure

Mechanical Preparation

  1. Confirm the 1000 Torr pressure range matches the process requirements.
  2. Verify the 8 VCR female connection against the chamber port.
  3. Inspect sealing surfaces for scratches and contamination.
  4. Use compatible VCR sealing components.
  5. Install the gauge without introducing excessive mechanical stress.
  6. Check the process connection for leakage after assembly.

Electrical Preparation

  1. Prepare the required ±15 VDC power supply.
  2. Confirm the exact connector configuration for the FA suffix.
  3. Check the connector pin assignment against the manufacturer diagram.
  4. Connect the 0–10 VDC output to a compatible analog input.
  5. Verify the signal reference and grounding arrangement.
  6. Check the pressure reading after thermal stabilization.

Commissioning Consideration: Allow the heated sensor to reach its specified operating temperature before evaluating measurement stability.

08 | Calibration, Maintenance & Troubleshooting

Condition Inspection Direction
Pressure reading drift Check zero stability and thermal conditions.
Slow signal response Inspect process connection and signal acquisition settings.
Unstable analog output Check power quality, grounding, and connector contacts.
Unexpected pressure offset Verify the reference pressure and calibration condition.
Process contamination Review process deposits and cleaning requirements.
Heating abnormality Check the heating system and manufacturer service instructions.

Maintenance Recommendations:

  • Monitor zero and span stability at scheduled intervals.
  • Inspect the VCR sealing interface during maintenance.
  • Check the electrical connector for damage or contamination.
  • Compare pressure readings against a calibrated reference.
  • Review thermal stabilization before adjusting zero settings.
  • Follow the manufacturer's service procedures for internal maintenance.

09 | Controller Compatibility & System Integration

The MKS 728A13TCE2FA provides a 0–10 VDC pressure signal and requires a compatible ±15 VDC supply.

The supplied application information identifies the following MKS instruments as potential system partners:

  • MKS PR4000B: Pressure controller and readout integration, subject to configuration verification.
  • MKS PDR2000A: Pressure display and power interface, subject to connector and signal compatibility.
  • PLC Analog Input Modules: Compatible voltage input channels with suitable signal conditioning.
  • Vacuum Process Controllers: Systems that support the specified analog output and power requirements.

Before integration, verify power supply capacity, signal scaling, connector pinout, and controller input specifications. Similar product names do not guarantee direct electrical compatibility.

10 | Industrial Applications

  • Semiconductor Manufacturing: Monitors absolute pressure in process chambers.
  • Chemical Vapor Deposition: Provides pressure feedback during CVD operations.
  • Physical Vapor Deposition: Supports vacuum pressure monitoring during coating processes.
  • Vacuum Coating Systems: Measures chamber pressure during industrial deposition.
  • Process Gas Systems: Monitors pressure in compatible corrosive gas environments.
  • Vacuum Equipment Retrofits: Supports upgrades to existing pressure measurement systems.

11 | Product Supply, Warranty & Shipping

Brand MKS Instruments
Model 728A13TCE2FA
Product Description 728A Heated Absolute Baratron® Capacitance Manometer
Product Condition New & Original in Factory Packing
Warranty Factory Warranty: 12 Months
Shipping Methods FedEx, UPS, DHL
Delivery Information International shipping options available

Standard Packaging List:

  • 1 × MKS Instruments 728A13TCE2FA Heated Capacitance Manometer.
  • Protective transportation packaging.
  • Product identification and configuration information, where supplied.

Contact our sales team to confirm stock, connector configuration, delivery time, and quotation details.

Frequently Asked Questions

1. Why does a heated Baratron gauge operate at 100°C instead of ambient temperature?

Process gases can condense or leave deposits on cooler internal surfaces. Maintaining the sensing assembly at 100°C helps reduce these effects. This is particularly useful in processes involving condensable precursors and reactive chemical by-products. The process temperature and gas chemistry must still remain within the instrument's compatibility limits.

2. How should engineers interpret the zero and span temperature coefficients?

The zero coefficient describes temperature-related changes in the zero-pressure reference. The span coefficient describes changes in measurement sensitivity. Both values affect measurement performance when ambient conditions change. Engineers should consider these coefficients when designing calibration intervals and pressure measurement uncertainty budgets.

3. Can the 728A13TCE2FA replace a non-heated 626D series gauge?

Not automatically. The 728A uses a heated sensing assembly, while the 626D is an unheated design. Their pressure ranges, fittings, electrical connectors, and controller requirements may differ. Compare the complete mechanical and electrical configurations before selecting a replacement.

4. What practical checks help prevent inaccurate readings during semiconductor process commissioning?

Check flange cleanliness, metal sealing integrity, power supply stability, and signal grounding. Allow sufficient time for the sensor to reach thermal equilibrium. Then compare the output against a calibrated reference instrument. Also verify that process deposits do not obstruct the pressure connection.

5. How should buyers choose between the FA and FB configurations?

Start with the original equipment part number and manufacturer ordering documentation. Compare connector pin count, cable assembly, accuracy code, power configuration, and vacuum fitting. The supplied FB description identifies a 15-pin D-sub connector, while the supplied FA description identifies a 9-pin connector. Obtain confirmation from the nameplate or manufacturer documentation before purchasing either version.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.