Home XNX-AMSV-FNIV1 Honeywell XNX Series IR Transmitter
XNX-AMSV-FNIV1 Honeywell XNX Series IR Transmitter
XNX-AMSV-FNIV1 Honeywell XNX Series IR Transmitter
XNX-AMSV-FNIV1 Honeywell XNX Series IR Transmitter
XNX-AMSV-FNIV1 Honeywell XNX Series IR Transmitter
XNX-AMSV-FNIV1 Honeywell XNX Series IR Transmitter
XNX-AMSV-FNIV1 Honeywell XNX Series IR Transmitter

XNX-AMSV-FNIV1 Honeywell XNX Series IR Transmitter

  • Manufacturer: Honeywell

  • Product No.: XNX-AMSV-FNIV1

  • Condition: In stock

  • Product Type: Universal Gas Transmitter

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 6800g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

XNX-AMSV-FNIV1 Engineering Architecture & System Overview

The XNX-AMSV-FNIV1 gas detection transmitter from Honeywell integrates advanced digital fieldbus communication with robust milli-Volt infrared sensing technology. Built within a rugged marine-grade 316 Stainless Steel housing, this intelligent unit combines HART over 4-20mA functionality with Foundation Fieldbus protocol connectivity. Pre-configured with an integrated MPD Infrared Methane sensor covering 0-100% LEL, it provides continuous combustible gas monitoring designed specifically for harsh industrial and offshore environments.

Global PLC Spare HUB's Insight: When migrating legacy control infrastructures to modern digital plant networks, deploying the XNX-AMSV-FNIV1 allows instrumentation engineers to leverage high-speed Foundation Fieldbus architecture while retaining reliable analog backup loops, effectively preventing data dropouts during severe environmental transients.

XNX-AMSV-FNIV1 Suffix Breakdown & Configuration Matrix

Part Number Code Engineering Parameter Definition
XNX-AMSV-FNIV1 (Base Series) Honeywell XNX Universal Transmitter with digital and analog transmission
Approval (A) ATEX, IECEx, and INMETRO certified for explosive hazardous locations
Entry Type (M) 5 x M25 threaded cable entry ports for heavy-duty armored conduit installation
Material Personality (S) Corrosion-resistant painted 316 Stainless Steel enclosure (6.8 Kg deadweight)
Sensor Personality (V) mV version interface optimized for MPD, Sensepoint, and Model 705 sensors
Communication Option (F) Foundation Fieldbus digital network communication protocol
Local HART (N) No local display screen installed (remote configuration via network)
Sensor Range (IV1) Pre-installed MPD Infrared Methane sensor measuring 0-100% LEL (0-5% v/v)

Technical Specifications & Performance Parameters

  • Brand & Model: Honeywell XNX-AMSV-FNIV1 (XNX Series)
  • Detection Technology: Infrared (IR) absorption principle specialized for Methane hydrocarbon monitoring
  • Measuring Range: 0 to 100% LEL or 0 to 5% volume fraction
  • Communication Protocols: Foundation Fieldbus digital bus and HART protocol over 4-20mA loop
  • Enclosure Protection: IP66/67 rated painted 316 stainless steel casing resistant to salt mist and corrosive chemicals

System Diagnostics & Advanced Fault Reporting

  • Optics Health Monitoring: Continuous self-monitoring of infrared emitter intensity and detector optical window cleanliness to prevent unannounced blind spots.
  • Bus Communication Diagnostics: Real-time packet error checking and link status reporting via Foundation Fieldbus to alert control systems of network degradation.
  • Sensor Circuit Supervision: Continuous resistance and impedance testing of the milli-Volt interface circuitry to detect open or shorted sensor leads instantly.

Target Equipment Compatibility & Application Environments

  • Compatible Hardware: MPD infrared hydrocarbon sensors, Sensepoint toxic/combustible sensors, and Model 705 catalytic elements.
  • Application Scenarios: Offshore oil drilling rigs, floating production vessels, natural gas compressor stations, and onshore petrochemical refining terminals.

Warranty, Packaging & Express Logistics

  • Packaging Details: Factory-sealed XNX-AMSV-FNIV1 transmitter assembly, protective dust covers, and multi-language technical documentation.
  • Quality Assurance: Backed by a full 12-month commercial warranty covering manufacturing and material defects.
  • Global Shipping: 24 to 48-hour expedited fulfillment via Fedex, UPS, and DHL global courier networks.

Selection Guide & Model Comparison

Selecting the correct transmitter variant depends heavily on your plant's control network architecture. The XNX-AMSV-FNIV1 features an integrated Foundation Fieldbus communication card and an incoming MPD infrared methane sensor, making it ideal for modern digital bus networks. Conversely, alternative baseline configurations like the XNX-AMSV-NNNNN ship without pre-installed sensors or fieldbus options, requiring separate sensor selection and standard 4-20mA loop wiring. Engineers should verify DCS network compatibility before procurement.

Frequently Asked Questions (FAQ)

Q: How does the Foundation Fieldbus option affect integration with distributed control systems?

A: The Foundation Fieldbus interface allows multi-drop digital communication over a single twisted-pair cable, transmitting precise gas concentration values, device status, and diagnostic blocks directly into DCS engineering environments.

Q: What maintenance steps are recommended when operating the MPD infrared sensor in dusty environments?

A: Schedule periodic optical window inspections using the transmitter's diagnostic output levels; clean the sapphire lenses with a lint-free cloth and isopropyl alcohol when optical degradation warnings appear.

Q: Can the 316 stainless steel enclosure be grounded safely in high-voltage switchyards?

A: Yes, the housing includes dedicated internal and external earth grounding terminals to maintain electromagnetic shielding and prevent ground loops in heavy industrial electrical installations.

Q: What occurs to the fieldbus data stream if the internal sensor experiences a sudden open circuit?

A: The transmitter immediately updates its diagnostic status block to reflect a sensor fault, transmitting a high-priority alarm flag down the Foundation Fieldbus network to alert the control room operator.

Q: How do I choose between standard analog loops and the Foundation Fieldbus model?

A: Choose the Foundation Fieldbus model when your facility utilizes digital asset management systems and multi-variable bus architecture; choose standard analog units for conventional hardwired PLC safety instrumented systems.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.