Home 622D13TQD MKS Baratron 622D Series Precision 1000 Torr Manometer

622D13TQD MKS Baratron 622D Series Precision 1000 Torr Manometer

  • Manufacturer: MKS Instruments

  • Product No.: 622D13TQD

  • Condition: In stock

  • Product Type: Absolute Pressure Sensor

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

622D13TQD | Absolute Pressure Measurement for Vacuum Process Control

The MKS Instruments 622D13TQD is an unheated absolute capacitance manometer from the Baratron® 622D Series. It measures absolute pressure through a precision capacitive diaphragm. Its 1000 Torr full-scale range supports vacuum systems and process pressure monitoring.

Unlike thermal conductivity gauges, this instrument measures pressure independently of gas composition. Its capacitive sensing principle eliminates the need for gas-dependent correction factors. This characteristic supports consistent pressure measurement across different process gases.

The instrument provides a linear 0–10 VDC analog output. A 5-pin terminal block provides the electrical connection. Its NW25-KF vacuum fitting supports convenient integration into compatible vacuum pipelines.

The unheated construction operates at ambient temperature. Inconel® and Incoloy® nickel alloys form the specified wetted material system. These materials support demanding process environments where chemical compatibility matters.

Product Configuration Breakdown

Ordering Code Configuration
622D Unheated absolute Baratron® capacitance manometer
13T 1000 Torr full-scale pressure range
Q NW25-KF vacuum fitting
D Specified accuracy configuration: ±0.15% of Reading, 10–1000 Torr, according to the supplied ordering description
Complete Model 622D13TQD

Electrical configuration: 5-pin terminal block, without built-in control relays.

Important ordering note: The supplied ordering information identifies the D accuracy option as ±0.15% of Reading over 10–1000 Torr. Another general configuration description identifies ±0.25% of Reading as standard accuracy. Confirm the exact accuracy specification against the instrument nameplate and applicable factory documentation before final acceptance.

Technical Specifications

Parameter Specification
Manufacturer MKS Instruments
Product Brand Baratron®
Model 622D13TQD
Product Series 622D
Product Type Unheated Absolute Capacitance Manometer
Measurement Principle Absolute capacitive diaphragm measurement
Full-Scale Range 1000 Torr
Pressure Equivalent Approximately 133.3 kPa
Accuracy Configuration ±0.15% of Reading, 10–1000 Torr, as supplied for option D
Standard Accuracy Reference ±0.25% of Reading, according to the supplied general description
Output Signal 0–10 VDC linear analog output
Output Load Greater than 10 kΩ
Power Supply ±15 VDC ±5%
Power Consumption 35 mA
Electrical Connector 5-pin terminal block
Vacuum Connection NW25-KF
Resolution 0.001% of Full Scale
Zero Temperature Coefficient 0.04% of Reading/°C
Operating Temperature 0°C to +50°C
Overpressure Limit 45 psia (310 kPa)
Wetted Materials Inconel® and Incoloy® nickel alloys
Measurement-Side Volume 6.3 cm³
Heating Configuration Unheated
Built-in Control Relays Not included
Compliance CE compliant
Warranty 12 months

Measurement Technology – Absolute Capacitance Principle

The 622D uses a thin sensing diaphragm as its pressure-sensitive element. Pressure differences across the diaphragm cause small mechanical deflections. The internal capacitive circuit converts these deflections into an electrical measurement signal.

The instrument references absolute pressure rather than relying on atmospheric pressure as its measurement baseline. This distinction matters in vacuum process applications where ambient pressure changes can affect gauge-pressure measurements.

Key engineering advantages:

  • Gas-independent measurement: The sensing principle responds to pressure rather than gas thermal conductivity.
  • Linear output: The 0–10 VDC signal supports analog pressure acquisition.
  • Fine resolution: The specified resolution reaches 0.001% of full scale.
  • Low measurement-side volume: The 6.3 cm³ internal volume supports integration into vacuum process systems.
  • Unheated operation: The instrument does not require an elevated internal operating temperature.

For process engineers, gas independence is particularly valuable when recipes involve different gases or changing gas compositions. The same pressure measurement principle applies without introducing gas-specific thermal correction factors.

Accuracy, Resolution & Temperature Performance

1. Measurement Accuracy

The supplied ordering description specifies ±0.15% of Reading over 10–1000 Torr for the D accuracy configuration. The general specification also references ±0.25% of Reading as standard accuracy.

Accuracy includes hysteresis, non-linearity, and non-repeatability. Engineers should distinguish accuracy from resolution when evaluating measurement uncertainty.

2. Measurement Resolution

The specified resolution is 0.001% of full scale.

For the 1000 Torr range, this corresponds to approximately 0.01 Torr. This figure represents the stated resolution rather than guaranteed absolute accuracy.

3. Temperature Characteristics

The specified zero temperature coefficient is 0.04% of Reading per °C. The operating ambient temperature range is 0°C to +50°C.

Because this model uses an unheated design, process engineers should consider ambient temperature changes during measurement validation. Avoid assuming that unheated operation eliminates temperature-related measurement effects.

Analog Output & Electrical Integration

The 622D13TQD provides a 0–10 VDC analog output. The output represents the measured pressure across the configured full-scale range.

Electrical Parameter Value
Positive Supply +15 VDC ±5%
Negative Supply -15 VDC ±5%
Current Requirement 35 mA
Analog Output 0–10 VDC
Minimum Output Load Impedance Greater than 10 kΩ
Connector 5-pin terminal block

PLC and data acquisition integration:

  • Use a compatible bipolar ±15 VDC power supply.
  • Connect the analog output to a suitable 0–10 V input channel.
  • Verify the input impedance exceeds 10 kΩ.
  • Check signal common and grounding arrangements.
  • Configure the receiving system for the 1000 Torr measurement range.

Do not connect the instrument to a 24 VDC-only supply without a suitable power conversion arrangement. The specified supply requires both positive and negative rails.

Vacuum Connection & Installation

The Q configuration provides an NW25-KF vacuum fitting. This connection supports installation in compatible vacuum manifolds and process chambers.

Installation procedure:

  1. Inspect the NW25-KF mating surfaces before assembly.
  2. Check the centering ring and seal for damage or contamination.
  3. Align the gauge with the vacuum connection.
  4. Install the compatible clamp and sealing components.
  5. Secure the electrical terminal wiring.
  6. Verify supply polarity before applying power.
  7. Allow the instrument to stabilize under controlled conditions.
  8. Compare the output against a suitable reference pressure.

Keep the sensing chamber clean during installation. Process residue or particles can affect diaphragm performance and measurement stability.

Commissioning & Measurement Verification

Correct commissioning helps identify electrical errors before the gauge enters production service.

Recommended verification sequence:

  • Confirm the complete ordering code and 1000 Torr range.
  • Measure both positive and negative supply rails.
  • Check the terminal connections and output wiring.
  • Verify the receiving instrument accepts a 0–10 VDC signal.
  • Check the output at known pressure points.
  • Compare readings with a traceable reference instrument.
  • Record zero and span performance for future trend analysis.

Do not adjust the zero point simply to compensate for an unstable power supply. First verify electrical conditions, thermal stabilization, and the reference pressure.

Materials, Process Compatibility & Overpressure Protection

The measurement-side wetted materials include Inconel® and Incoloy® nickel alloys. These materials support applications requiring suitable corrosion resistance.

However, material selection must consider the actual gas composition, concentration, temperature, and contamination profile. Verify chemical compatibility before introducing aggressive process gases.

The specified overpressure limit is 45 psia (310 kPa). This limit is not a normal operating pressure target. Protect the diaphragm against pressure excursions during venting, purging, and process transitions.

Applications in Vacuum Process Systems

  • Semiconductor manufacturing: Monitor absolute pressure in compatible vacuum process equipment.
  • Thin-film deposition: Provide analog pressure feedback for vacuum chamber monitoring.
  • Industrial vacuum systems: Measure chamber pressure independently of gas composition.
  • Coating equipment: Support pressure monitoring during controlled deposition processes.
  • Research laboratories: Supply analog pressure measurements for vacuum test systems.
  • Process gas systems: Monitor pressure across applications involving different gas mixtures.

Standards & Compliance

  • CE: CE compliant according to the supplied product specifications.

Confirm the applicable declaration and installation requirements against the documentation supplied with the instrument.

Package Contents

  • 1 × MKS Instruments 622D13TQD Baratron® 622D Series capacitance manometer.
  • 1 × Integrated 5-pin terminal block electrical interface.
  • NW25-KF vacuum connection in the specified instrument configuration.

Power supplies, signal cables, KF clamps, centering rings, and external accessories are not confirmed as included. Please verify the required installation accessories when ordering.

Frequently Asked Questions

Q1: Can the 622D13TQD measure both vacuum pressure and pressures approaching atmospheric pressure?

Yes. Its 1000 Torr full-scale range covers absolute pressures from the vacuum region up to its specified full-scale value. Select the range according to the highest expected process pressure and required measurement accuracy.

Q2: Why should engineers distinguish absolute pressure from gauge pressure?

Absolute pressure uses a vacuum reference, while gauge pressure references local atmospheric pressure. This difference becomes important when comparing measurements across facilities or operating conditions with changing atmospheric pressure.

Q3: What problems can condensable vapors cause in an unheated capacitance manometer?

Condensation can contaminate the sensing chamber and affect diaphragm response. Evaluate the vapor composition and process temperature before installation. Consider suitable system heating or protection measures when the application requires them.

Q4: How should engineers investigate a slow response or unstable analog signal?

Check the power supply rails, signal grounding, vacuum connection, and process contamination first. Compare the gauge reading against an independent reference. Also inspect pressure pulsations and possible condensate accumulation before concluding that the sensor has failed.

Q5: Should buyers choose a 1000 Torr gauge for every vacuum application?

No. The full-scale range should match the process operating window. A smaller range can provide better absolute pressure resolution for low-pressure applications. A 1000 Torr model suits applications requiring a wider measurement span, including processes approaching atmospheric pressure.

Ordering Information, Warranty & Shipping

  • Manufacturer: MKS Instruments
  • Product Family: Baratron®
  • Series: 622D
  • Part Number: 622D13TQD
  • Measurement Range: 1000 Torr
  • Vacuum Connection: NW25-KF
  • Electrical Interface: 5-pin terminal block
  • Condition: New, factory original packing
  • Warranty: 12 months
  • Shipping: FedEx, UPS, and DHL international delivery options.

Contact Global PLC Spare HUB for pricing, availability, and technical selection assistance. Please provide your existing gauge model, required pressure range, and electrical interface for replacement verification.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.