FC-FANWR-24R Honeywell Fan Assembly Kit 24VDC Cooling Unit
Manufacturer: Honeywell
Product No.: FC-FANWR-24R
Condition: In stock
Product Type: Fan Assembly Kit
Product Origin: USA
Payment: T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview | Dual-Fan Cooling and Monitoring Assembly
The Honeywell FC-FANWR-24R is a 24 VDC fan assembly kit for industrial control equipment. It provides forced-air cooling and integrated fan-status monitoring.
The assembly contains two Papst 4184N/17X ball-bearing fans and a dedicated PCB 07209. Both fans mount on a common mounting plate. This arrangement provides a compact cooling unit with centralized electrical connections.
The fan electronics monitor the rotational speed of each fan. A dedicated green LED indicates whether each fan exceeds its minimum operating speed. When both fans meet the speed threshold, the potential-free readback contact closes.
The FC-FANWR-24R combines cooling performance with electrical status feedback. It helps maintenance teams monitor fan operation without relying solely on visual inspection.
Technical Specifications | Product Identification
| Parameter | Specification |
| Brand | Honeywell |
| Product Model | FC-FANWR-24R |
| Assembly Reference | FS-FANWR-24R |
| Product Type | Fan Assembly Kit |
| Fan Manufacturer | Papst |
| Fan Model | 4184N/17X |
| Fan Bearing | Ball Bearing |
| Finger Guard Manufacturer | Papst |
| Finger Guard Model | LZ30 |
| Internal PCB | 07209 |
| Number of Fans | 2 |
| Nominal Supply Voltage | 24 VDC |
| Operating Voltage Range | 12–29 VDC |
| Power Consumption | 9.5 W |
| Fuse Rating | 2 A slow-blow |
| Fuse Dimensions | 5 × 20 mm |
| Total Airflow | 360 m³/h (211.8 CFM) |
| Noise Level | 52 dB |
| Nominal Fan Speed | 3,200 RPM |
| Minimum Readback Speed | 1,500 RPM ±100 RPM |
| Operating Temperature | -30°C to +75°C (-22°F to +167°F) |
| Ingress Protection | IP20 |
| Service Life at 40°C | 85,000 hours |
| Service Life at 75°C | 37,500 hours |
| Dimensions | 391 × 142 × 51 mm |
| Dimensions (Imperial) | 15.4 × 5.59 × 2.01 in |
| Weight | 1.7 kg |
Mechanical Architecture | Fan and PCB Configuration
The assembly integrates two axial fans with a dedicated monitoring circuit. Both fans share one mounting plate and electrical interface.
- Fan Configuration: Two Papst 4184N/17X ball-bearing fans.
- Monitoring PCB: PCB 07209 processes fan-status signals.
- Mechanical Support: Common mounting plate supports both fans.
- Finger Protection: Papst LZ30 finger guards.
- Electrical Interface: Four-pole connector for external power and feedback wiring.
- Assembly Dimensions: 391 × 142 × 51 mm.
The common mounting arrangement simplifies mechanical installation. The four-pole connector provides a centralized interface for power and status wiring.
Cooling Performance | Airflow and Operating Characteristics
The two-fan assembly delivers a combined airflow of 360 m³/h. This equals approximately 211.8 CFM.
| Performance Item | Value |
| Number of Fans | 2 |
| Nominal Rotational Speed | 3,200 RPM |
| Minimum Monitoring Threshold | 1,500 RPM ±100 RPM |
| Combined Airflow | 360 m³/h |
| Airflow in CFM | 211.8 CFM |
| Combined Noise Level | 52 dB |
The airflow specification describes the complete assembly. It does not represent the airflow of each individual fan.
Engineers should consider cabinet ventilation, inlet restrictions, filter resistance, and internal heat generation. These factors influence actual cooling performance after installation.
Fan Monitoring | LED Indication and Readback Contact
The FC-FANWR-24R includes individual fan-speed indication and a potential-free readback contact.
Individual LED Indication
- Each fan has an associated green LED.
- The LED illuminates when its fan exceeds the minimum speed.
- Each indicator provides direct visual confirmation of fan rotation speed status.
Potential-Free Readback Contact
- The contact closes when both fans exceed the minimum speed threshold.
- The contact also closes for approximately 15 seconds during power-up.
- The contact provides a remote status interface for external monitoring circuits.
- The contact supports a maximum switching voltage of 300 VDC or 240 VAC.
- The maximum switching current is 0.5 A.
- The maximum switching power is 10 W.
The minimum monitoring threshold is 1,500 RPM ±100 RPM. Both fans must satisfy this condition for normal readback closure after the startup period.
Engineering Note: The startup contact closure lasts approximately 15 seconds. Do not interpret this temporary signal as proof of sustained fan operation.
Electrical Interface | Power Supply and Protection
| Electrical Parameter | Specification |
| Nominal Input | 24 VDC |
| Permitted Voltage Range | 12–29 VDC |
| Power Consumption | 9.5 W |
| Fuse | 2 A slow-blow |
| Fuse Size | 5 × 20 mm |
| Reverse Polarity Protection | Not provided |
| External Connector | Four-pole connector |
| Wire Stripping Length | 7 mm |
| Terminal Tightening Torque | 0.4–0.5 Nm |
| Recommended Screwdriver | SD 0.6 × 3.5 – DIN 5264 |
Critical Wiring Precaution: The assembly does not provide reverse polarity protection. Verify DC polarity before connecting the power supply.
Use the specified fuse rating and connector wiring arrangement. Incorrect polarity or unsuitable protection may damage the fan electronics.
Installation Guide | Mechanical and Electrical Connection
- Verify the Model: Confirm the assembly reference and required mounting dimensions.
- Inspect the Assembly: Check both fans, finger guards, PCB, and mounting plate.
- Prepare the Mounting Position: Ensure sufficient clearance for airflow and maintenance access.
- Secure the Unit: Install the assembly using the equipment manufacturer's mounting instructions.
- Prepare Wiring: Strip external wires to the specified 7 mm length.
- Connect Power: Verify 24 VDC polarity and supply compatibility.
- Connect Readback: Wire the potential-free contact to the designated monitoring circuit.
- Tighten Terminals: Apply 0.4–0.5 Nm tightening torque.
- Check Protection: Confirm the 2 A slow-blow fuse specification.
- Restore Power: Observe both fan indicators and verify the readback signal.
Follow the equipment manufacturer's installation drawings for mounting orientation and terminal assignments. Do not rely on connector position alone.
Commissioning and Maintenance | Practical Inspection
Commissioning should verify airflow, rotational speed, electrical supply, and remote status feedback.
- Supply Measurement: Confirm the input remains within 12–29 VDC.
- Startup Observation: Allow for the approximately 15-second startup contact behavior.
- LED Inspection: Confirm that both green LEDs indicate sufficient fan speed.
- Speed Verification: Check the minimum threshold of 1,500 RPM ±100 RPM.
- Contact Testing: Verify readback closure when both fans reach the required speed.
- Airflow Inspection: Check for blocked inlets, restricted outlets, or dust accumulation.
- Noise Assessment: Investigate unusual vibration or changes in operating noise.
- Electrical Inspection: Check connector tightness, fuse condition, and polarity.
Inspect the fan assembly during scheduled equipment maintenance. Replace damaged fans or guards according to the equipment manufacturer's service procedures.
Environmental and Mechanical Requirements
| Environmental Item | Specification |
| Operating Temperature | -30°C to +75°C |
| Maximum Specified Temperature | 75°C |
| Ingress Protection | IP20 |
| Service Life at 40°C | 85,000 hours |
| Service Life at 75°C | 37,500 hours |
| Physical Length | 391 mm |
| Physical Width | 142 mm |
| Physical Depth | 51 mm |
| Net Weight | 1.7 kg |
The IP20 rating provides basic protection against finger access. It does not provide protection against water ingress.
Install the assembly inside a suitable enclosure. Prevent direct exposure to liquids, excessive dust, and mechanical impact.
Compatibility and System Integration
The FC-FANWR-24R provides cooling and status feedback for compatible Honeywell equipment configurations.
- Power Compatibility: The external supply must provide 12–29 VDC.
- Nominal Supply: 24 VDC is the specified nominal operating voltage.
- Monitoring Interface: The potential-free contact supports external status monitoring.
- Electrical Loading: External circuits must respect the contact's switching limits.
- Mechanical Compatibility: Verify the 391 × 142 × 51 mm mounting envelope.
- Replacement Identification: Confirm FC-FANWR-24R and FS-FANWR-24R references before ordering.
Do not assume universal compatibility across Honeywell controller platforms. Confirm the original equipment model, mounting arrangement, connector wiring, and approved replacement reference.
Certification and Compliance Information
- Ingress Protection: IP20.
- Electrical Supply: 24 VDC nominal.
- Temperature Capability: -30°C to +75°C.
- Safety Consideration: Reverse polarity protection is not provided.
- Certification: Confirm applicable approvals through the exact manufacturer documentation.
The supplied technical information does not identify specific CE, UL, ATEX, or IECEx approvals. Verify certification requirements before installation in regulated environments.
Packaging and Delivery Information
- 1 × Honeywell FC-FANWR-24R Fan Assembly Kit.
- Integrated dual-fan assembly.
- Two Papst 4184N/17X fans.
- PCB 07209 and mounting plate.
- Papst LZ30 finger guards.
- Protective packaging for transportation.
- 12-month warranty.
- Shipping options through DHL, FedEx, or UPS.
Confirm the actual shipment contents and connector accessories before ordering. Contact our team for availability and delivery information.
Frequently Asked Questions | Engineering and Troubleshooting
Q1: Why does the readback contact close during startup even when the fans have not reached normal speed?
The monitoring circuit closes the contact for approximately 15 seconds during power-up. This behavior forms part of the specified startup sequence. Engineers should evaluate the contact after this initial period.
Q2: What does it mean when one green LED illuminates but the other remains OFF?
The illuminated LED indicates that its associated fan exceeds the minimum speed threshold. The other fan may have insufficient speed or a mechanical problem. Inspect its supply, connector, rotor movement, and airflow path.
Q3: Can the readback contact directly power an external alarm or relay?
The contact provides a potential-free switching interface. Its maximum ratings are 300 VDC or 240 VAC, 0.5 A, and 10 W. Verify all three limits before connecting an external circuit. Use an appropriate interface relay when necessary.
Q4: What should maintenance engineers check when the assembly produces abnormal noise?
Inspect the fan bearings, mounting plate, finger guards, and surrounding enclosure. Check for dust accumulation and mechanical contact. Compare operating noise with the specified 52 dB assembly rating under comparable conditions.
Q5: Why must engineers avoid connecting the power supply with reversed polarity?
The assembly does not include reverse polarity protection. Incorrect polarity can damage its internal electronics. Verify positive and negative connections with a meter before energizing the unit.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.