KFD2-SR2-Ex1.W.LB Pepperl+Fuchs Switch Amplifier
Manufacturer: Pepperl+Fuchs
Product No.: KFD2-SR2-Ex1.W.LB
Condition: In stock
Product Type: Switch Amplifier
Product Origin: DE
Payment: T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Pepperl+Fuchs KFD2-SR2-Ex1.W.LB Switch Amplifier
The KFD2-SR2-Ex1.W.LB is a one-channel isolated switch amplifier from Pepperl+Fuchs. It interfaces dry contact and NAMUR sensors with control-side equipment in industrial automation systems.
The module transfers field input signals through reinforced galvanic isolation and provides relay-based control outputs. Its second output can be configured for signal transmission or fault indication. The device also supports line fault detection (LFD), reversible operating modes, and signal splitting with one input and two outputs.
Designed for safety-related applications up to SIL 2 and systematic capability SC 3 according to IEC/EN 61508, this switch amplifier supports reliable signal conditioning between hazardous-area field devices and control systems.
01 | Signal Path and Functional Architecture
| Signal Stage | Function | Technical Details |
|---|---|---|
| Field Input | Sensor signal acquisition | Dry contact or NAMUR input |
| Input Monitoring | Field circuit supervision | Line fault detection for cable breakage and short circuit |
| Signal Processing | Switching logic | Reversible operating mode, DIP switch configuration |
| Output I | Control signal transmission | Relay output |
| Output II | Signal duplication or fault reporting | Relay output, configurable for signal or fault message |
| System Fault Reporting | Collective fault indication | Power Rail |
Functional highlights:
- One-channel isolated barrier for digital input signals.
- Compatible with dry contact and NAMUR field devices.
- One input with two relay outputs for signal splitting.
- Line fault detection for open-circuit and short-circuit conditions.
- Reversible switching behavior through DIP switch configuration.
- Power supply through Power Rail or terminals 14+ and 15-.
02 | Terminal Assignment and Wiring Reference
| Terminal | Connection | Purpose |
|---|---|---|
| 1+, 2+, 3- | Field side | Digital input connection |
| 7, 8, 9 | Control side | Relay Output I |
| 10, 11, 12 | Control side | Relay Output II: signal or fault message |
| 14+, 15- | Power supply | 19–30 V DC supply connection |
The device supports two supply connection methods: Power Rail or direct terminal wiring. When using a Power Rail installation, the collective error message can also be transmitted through the rail.
Always confirm the terminal diagram on the device label and the manufacturer's wiring documentation before connecting field or control-side circuits.
03 | NAMUR Input Characteristics and Fault Detection
| Input Parameter | Specification |
|---|---|
| Signal Type | Digital input |
| Supported Sensor | Dry contact or NAMUR |
| Open-Circuit Voltage | Approximately 8 V DC |
| Short-Circuit Current | Approximately 8 mA |
| Switching Point | 1.2–2.1 mA |
| Switching Hysteresis | Approximately 0.2 mA |
| Line Break Detection | Input current ≤ 0.1 mA |
| Short-Circuit Detection | Input current greater than 6 mA |
| Minimum Pulse Duration | 20 ms |
| Minimum Pause Duration | 20 ms |
Line fault detection behavior:
- Normal input range: The NAMUR signal is evaluated according to the configured switching thresholds.
- Open circuit: Input current at or below 0.1 mA indicates a line break condition.
- Short circuit: Input current above 6 mA indicates a short-circuit condition.
These thresholds allow the control system to distinguish sensor switching states from wiring faults. Correct field wiring and sensor compatibility remain essential for reliable fault detection.
04 | Relay Outputs and Switching Capacity
The two relay outputs provide separate control-side connections. Output I transfers the input signal. Output II can transfer the signal or provide a fault message, depending on the configuration.
| Output Parameter | Rating |
|---|---|
| Output I | Relay, terminals 7, 8, 9 |
| Output II | Relay, terminals 10, 11, 12 |
| 250 V AC Contact Load | 2 A, cos φ greater than 0.75 |
| 126.5 V AC Contact Load | 4 A, cos φ greater than 0.75 |
| 40 V DC Contact Load | 2 A, resistive load |
| Minimum Switching Current | 2 mA at 24 V DC |
| Operate Delay | Approximately 20 ms |
| Release Delay | Approximately 20 ms |
| Mechanical Life | 10⁷ switching cycles |
| Maximum Switching Frequency | 10 Hz |
For FM-approved applications, the listed 30 V DC contact rating is 2 A with a resistive load. Check the applicable approval documentation and load category before selecting the switching circuit.
05 | Power Supply and Electrical Isolation
| Parameter | Value |
|---|---|
| Supply Connection | Power Rail or terminals 14+, 15- |
| Rated Supply Voltage | 19–30 V DC |
| Permitted Ripple | ≤ 10% |
| Rated Current | ≤ 45 mA |
| Power Dissipation | ≤ 0.9 W |
| Power Consumption | ≤ 0.9 W |
Galvanic isolation:
- Input to output: reinforced insulation, 300 V RMS rated insulation voltage.
- Input to power supply: reinforced insulation, 300 V RMS rated insulation voltage.
- Output to power supply: reinforced insulation, 300 V RMS rated insulation voltage.
- Output to output: reinforced insulation, 300 V RMS rated insulation voltage.
The reinforced isolation separates field, control, and supply circuits. This helps prevent unwanted electrical interaction between connected circuit groups.
06 | Functional Safety and Hazardous-Area Approvals
| Safety Parameter | Specification |
|---|---|
| Safety Integrity Level | SIL 2 |
| Systematic Capability | SC 3 |
| Functional Safety Standard | IEC/EN 61508:2010 |
EU-type examination certificate: PTB 00 ATEX 2080
| Approval / Protection Type | Marking or Certificate |
|---|---|
| ATEX Intrinsic Safety | II (1)G [Ex ia Ga] IIC |
| ATEX Dust Protection | II (1)D [Ex ia Da] IIIC |
| Mining Application | I (M1) [Ex ia Ma] I |
| Additional ATEX Marking | II (3)G [Ex ic Gc] IIC |
| Additional ATEX Certificate | TÜV 99 ATEX 1493 X |
| Additional Protection Marking | II 3G Ex ec nC IIC T4 Gc |
| IECEx Certificates | IECEx PTB 11.0034; IECEx TUN 19.0013X |
| IECEx Markings | [Ex ia Ga] IIC; [Ex ia Da] IIIC; [Ex ia Ma] I; Ex ec nC IIC T4 Gc |
| FM Certificate | FM19US0207X |
| FM Control Drawing | 116-0035 |
| UL Certificate | E106378 |
| cULus Control Drawing | 116-0473 |
Hazardous-area input parameters:
| Parameter | Ex ia / Ex ic Value |
|---|---|
| Output Voltage Uo | 10.5 V |
| Output Current Io | 13 mA |
| Output Power Po | 34 mW, linear characteristic |
Maximum safe voltage Um:
- Supply: 253 V AC / 125 V DC.
- Relay output: 253 V AC.
- Fault indication output: 40 V DC.
Important: Um is a maximum safe voltage, not the normal operating voltage or rated load voltage. The actual permissible circuit voltage must follow the applicable product ratings and approval documents.
Hazardous-area installation requires verification of the complete intrinsic safety loop, including field-device parameters, cable capacitance, cable inductance, and the associated control-side equipment. The module's approval alone does not establish suitability for every installation.
07 | Environmental, Mechanical and Compliance Data
| Parameter | Specification |
|---|---|
| Operating Temperature | -40 to +70 °C (-40 to +158 °F) |
| Protection Degree | IP20 |
| Connection Type | Screw terminals |
| Mounting | 35 mm DIN rail according to EN 60715:2001 |
| Dimensions (W × H × D) | 20 × 119 × 115 mm |
| Housing Type | B2 |
| Weight | Approximately 150 g |
| Display | LED indicators |
| Configuration | DIP switches |
| Labeling | Front labeling area |
Applicable directives and standards:
- EMC Directive 2014/30/EU: EN 61326-1:2013.
- Low Voltage Directive 2014/35/EU: EN 61010-1:2010 and listed amendments.
- EMC conformity: NE 21:2017, EN 61326-3-1:2017, EN IEC 61326-3-2:2018.
- Functional safety: IEC/EN 61508:2010.
- NAMUR input: EN 60947-5-6:2000.
- Enclosure protection: IEC 60529.
- ATEX-related standards: EN IEC 60079-0, EN 60079-7, EN IEC 60079-11, and EN IEC 60079-15 as listed in the product documentation.
08 | Commissioning and Field Maintenance Notes
- Verify sensor type: Confirm whether the field device is a dry contact or NAMUR sensor.
- Check input wiring: Verify terminal polarity and the connections at 1+, 2+, and 3-.
- Set operating mode: Check DIP switch positions against the required switching and fault response logic.
- Review output assignment: Confirm whether Output II is configured for signal duplication or fault reporting.
- Check supply voltage: Measure the DC supply at the module and confirm it remains within 19–30 V DC.
- Test LFD response: Perform approved open-circuit and short-circuit tests to verify field wiring supervision.
- Verify relay operation: Confirm switching response and connected load ratings during functional testing.
For safety-related applications, verify the complete safety function, configuration, and proof-test requirements against the applicable safety manual and project documentation.
09 | Supply, Warranty and Delivery
| Product Information | Details |
|---|---|
| Manufacturer | Pepperl+Fuchs |
| Model | KFD2-SR2-Ex1.W.LB |
| Product Type | Switch Amplifier / Isolated Barrier |
| Input | One-channel dry contact or NAMUR |
| Output | Two relay outputs |
| Product Condition | New & Original in Factory Packing |
| Warranty | Factory Warranty: 12 Months |
| Shipping | FedEx, UPS, DHL |
Contact Global PLC Spare HUB for KFD2-SR2-Ex1.W.LB pricing, availability, and delivery information. Provide your sensor type and required output configuration when requesting a quotation.
10 | Engineering FAQs
Q1: How should I select the DIP switch settings when replacing an existing unit?
Record the original switch positions before removing the old module. Compare them with the required input logic, reversible operating mode, and Output II assignment. Do not assume that a replacement module will operate correctly with factory-default settings. Confirm the final configuration against the wiring diagram and application logic.
Q2: Why might the relay output fail to switch even when the input LED changes state?
Check the selected operating mode, relay contact wiring, connected load, and output assignment. Also verify that the load does not fall below the specified minimum switching current or exceed the applicable contact rating. An input indication confirms signal detection, but it does not independently prove the external relay circuit is wired correctly.
Q3: Can the second relay output be used to send a separate alarm to the PLC?
Yes. Output II can be configured for a signal or fault message. For a separate alarm, verify the selected DIP switch configuration and PLC input wiring. If Output II is assigned to fault reporting, it should not simultaneously be treated as an independent duplicate process signal.
Q4: What should engineers verify when connecting a NAMUR sensor through a long field cable?
Check the sensor's NAMUR compatibility, cable insulation, wiring polarity, and the total cable capacitance and inductance. Confirm that the measured current remains within the intended switching range. For hazardous-area circuits, include cable parameters in the intrinsic safety assessment rather than checking the barrier values alone.
Q5: What is the main difference between a switch amplifier and a standard digital input card in this application?
A switch amplifier provides signal conditioning and galvanic isolation between field and control circuits. This model also supports NAMUR signal evaluation, line fault detection, and relay-based output separation. A standard PLC digital input may not provide the same intrinsic safety interface or field wiring supervision. Select the device according to the sensor, hazardous-area classification, and required safety architecture.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.