Yokogawa ANB10D-425/CU2N Dual-Redundant ESB Bus Node Unit
01 | Hardware Identity and System Role
The Yokogawa ANB10D-425/CU2N is an ESB bus node unit for Yokogawa distributed control system installations. The ANB10D supports a dual-redundant ESB bus architecture. Its rack-mounted assembly provides an interface for connecting compatible I/O modules to the control system. This ordering configuration includes a dual-redundant power supply, a 220–240 V AC supply option, and an ESB bus connector unit. The specified assembly weighs approximately 10 kg, including eight I/O modules.
02 | Configuration Anatomy: Decode ANB10D-425/CU2N
| Ordering code | Configuration meaning | Engineering relevance |
|---|---|---|
| ANB10D | Node unit for dual-redundant ESB bus | Identifies the node hardware and bus architecture. |
| -4 | Dual-redundant power supply | Defines the selected power arrangement. |
| 2 | 220–240 V AC power supply | Specifies the supply voltage for this order configuration. |
| 5 | Basic type without explosion protection | Defines the supplied environmental and protection option. |
| /CU2N | ESB bus connector unit | Specifies the bus connection option. |
**Selected configuration:** ANB10D-425/CU2N - Dual-redundant ESB bus node. - Dual-redundant power supply. - 220–240 V AC input. - Basic type without explosion protection. - ESB bus connector unit included in the model designation.
03 | Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Yokogawa |
| Model | ANB10D-425/CU2N |
| Product type | ESB Bus Node Unit |
| Bus architecture | Dual-redundant ESB bus |
| Power supply configuration | Dual-redundant |
| Selected supply voltage | 220–240 V AC, 50/60 Hz |
| Power consumption | 230 VA, 120 W for the 220–240 V AC specification |
| Alternative family supply options | 100–120 V AC, 50/60 Hz; 24 V DC |
| Alternative family power consumption | 100–120 V AC: 200 VA, 120 W; 24 V DC: 5.5 A |
| Included I/O module quantity | 8 modules, as stated in the supplied weight specification |
| Mounting | 19-inch rack |
| Rack fastening | Four M5 screws with insulation bushes |
| Approximate weight | 10 kg, including eight I/O modules |
| Explosion protection | Not included |
The alternative supply ratings describe the ANB10D family. They do not change the selected 220–240 V AC configuration.
04 | Power and Bus Architecture
The ANB10D serves as a node within a dual-redundant ESB bus arrangement. Engineers should confirm the compatible control unit, bus coupler, and system topology. Its dual-redundant power supply provides the specified redundant power configuration. The actual redundancy performance depends on the complete power distribution design. Before integrating the node, verify:
- Control system and ESB bus compatibility.
- Approved bus coupler and connector arrangement.
- Power supply wiring and redundancy design.
- Installed I/O module types and quantity.
- System configuration and node addressing requirements.
The supplied information does not specify maximum node counts, bus cable lengths, or communication timing. Consult the applicable Yokogawa system documentation.
05 | Rack Installation and Cabinet Planning
The ANB10D-425/CU2N uses a 19-inch rack mounting arrangement. The supplied mounting specification identifies four M5 screws and insulation bushes. **Installation checklist**
- Confirm the rack accepts the unit's mounting dimensions.
- Check the available rack space and access for bus connections.
- Verify the 220–240 V AC supply and 50/60 Hz frequency.
- Inspect the insulation bushes and mounting hardware.
- Secure the assembly using the specified mounting arrangement.
- Connect the approved ESB bus interface.
- Verify I/O module positions against the cabinet drawings.
- Inspect wiring and grounding before commissioning.
The supplied product data does not provide exact rack clearance, terminal torque, or conductor size. Use the manufacturer's installation instructions for these details.
06 | Compatible Equipment and Industrial Applications
The ANB10D is designed for compatible Yokogawa ESB-based distributed control system installations.
- Distributed control systems: Connect supported I/O modules through the ESB bus architecture.
- Process automation: Integrate field I/O in engineered chemical, petrochemical, and manufacturing control systems.
- Power and utility plants: Support distributed process monitoring and control cabinets.
- Industrial plant expansion: Add a node where the existing control system supports the required hardware and configuration.
- Cabinet replacement projects: Replace a matching node after verifying bus, power, and module compatibility.
Confirm the exact controller family and I/O module compatibility before purchase. The model description alone does not establish compatibility with every Yokogawa system.
07 | Diagnostics and Commissioning Checks
The supplied specifications do not identify onboard diagnostic indicators, detailed fault codes, or specific diagnostic software functions. Use the relevant Yokogawa system tools and manuals for module-level diagnostics. During commissioning, check the following areas:
- Power supply: Confirm the AC input and investigate power alarms through approved system diagnostics.
- Redundant power: Verify both supply paths according to the system's commissioning procedure.
- ESB communication: Check connector seating, bus wiring, and controller recognition.
- I/O configuration: Compare installed module positions with the system configuration.
- Node identification: Confirm addressing and configuration match the engineering records.
- Field signal validation: Test representative I/O points through their connected modules.
**Field example:** If the controller does not recognize a newly installed node, check the ESB connection and configuration first. Then verify the power supply and installed module arrangement. These checks help isolate installation issues before replacing hardware.
08 | Compatibility and Procurement Review
Confirm these details before ordering a replacement or expansion unit:
- Complete model code: ANB10D-425/CU2N.
- Existing ESB bus architecture and compatible control unit.
- Required connector unit and bus cable arrangement.
- Installed I/O module types and quantity.
- 220–240 V AC supply availability.
- Rack mounting provisions and cabinet space.
- Environmental requirements and explosion protection classification.
The selected basic configuration does not include explosion protection. Confirm site requirements before installation in any classified area.
09 | Global PLC Spare HUB's Insight
The ANB10D should be selected as a complete node assembly rather than as an isolated rack component. Its suitability depends on the ESB architecture, power arrangement, and installed I/O modules. For example, during a control cabinet expansion, an engineer may need to add another node while retaining the existing bus structure. The engineer should verify the controller's supported node capacity, cable arrangement, and configuration requirements. The stated 10 kg weight includes eight I/O modules. Confirm the actual supplied assembly and module complement when planning handling, rack loading, or a replacement project.
10 | Packaging, Warranty, and Shipping
- Product: Yokogawa ANB10D-425/CU2N ESB Bus Node Unit.
- Packaging: Protective packaging for industrial control equipment.
- Included configuration: Confirm the connector unit and eight-module assembly details with the supplier.
- Warranty: 12-month warranty, subject to applicable sales terms.
- Shipping carriers: FedEx, UPS, and DHL.
- Dispatch target: 24–48 hours after order confirmation and stock verification.
11 | Frequently Asked Questions
- Does the ANB10D-425/CU2N arrive with eight I/O modules installed? The supplied specification states an approximate weight of 10 kg, including eight I/O modules. Confirm the exact module types and package contents before ordering.
- 2. What is the difference between the ANB10D and a standard ESB node? The ANB10D is specified for a dual-redundant ESB bus architecture. Check the system design and official documentation when comparing it with other node models.
- 3. Can the existing cabinet support this assembly's weight? The stated weight is approximately 10 kg, including eight I/O modules. Check rack load capacity, mounting support, and handling requirements before installation.
- 4. Does the CU2N option identify the complete ESB cable assembly? The ordering code identifies an ESB bus connector unit. It does not confirm every required cable or accessory. Verify the complete connection arrangement against the system drawings.
- 5. Which details should I send for a system compatibility check? Provide the controller model, current ESB node type, bus arrangement, installed I/O modules, supply voltage, and full ordering code. These details support a more reliable selection review.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.