Product Introduction | 16-Point DC Output Control

The Allen-Bradley 1746-OB16 is a 16-point digital DC output module. It belongs to the SLC 500 programmable controller platform from Rockwell Automation.

This module provides one group of 16 sourcing outputs. It switches external DC loads through positive-side output control. Its nominal output voltage is 24 VDC, with a specified operating voltage range of 10–50 VDC.

The 1746-OB16 supports industrial output applications requiring compact channel density and controlled switching performance. Each point supports different current ratings according to ambient temperature. The module also provides defined switching delays and low off-state leakage current.

Its 16-channel architecture supports distributed machine-control functions. Typical applications include solenoid valves, interposing relays, indicator circuits, and other compatible DC loads.

Electrical Specifications | Model and Performance Data

Specification Technical Details
Manufacturer Rockwell Automation
Brand Allen-Bradley
Model / Catalog Number 1746-OB16
Product Series SLC 500
Module Type Digital DC Output Module
Output Technology Solid-State Transistor Output
Output Logic Source / Positive Logic
Number of Outputs 16
Output Grouping One group of 16 outputs
Nominal Output Voltage 24 VDC
Specified Voltage Range 10–50 VDC
Continuous Current per Point 1.5 A at 30°C; 1.0 A at 55°C
Maximum Module Current 6.4 A at 0–60°C
OFF-to-ON Delay 1.0 ms
ON-to-OFF Delay 0.1 ms
OFF-State Leakage Current 1 mA
Backplane Current 135 mA at 5.1 VDC
Heat Dissipation 7.6 W
Operating Temperature 0°C to 60°C
UPC 10662468067055
UNSPSC 32151705

Output Characteristics | Sourcing Technology

The 1746-OB16 uses sourcing output technology. Each active channel supplies positive DC voltage to its connected load.

  • Output Structure: Sixteen solid-state DC output channels.
  • Switching Logic: Positive-side load switching.
  • Field Voltage: Nominal 24 VDC.
  • Output Arrangement: One group containing 16 points.
  • Load Connection: Compatible DC loads with appropriate current requirements.
  • Switching Performance: Fast electronic response for discrete control operations.

When the PLC activates an output, the channel supplies current to the connected load. The external load circuit must provide the correct return path.

Wiring Consideration: Confirm terminal assignments and common connections using the official module wiring diagram. Do not treat sourcing outputs as sinking outputs.

Current Capacity and Load Distribution

Output current capacity depends on ambient temperature and total module loading. Engineers must evaluate both individual channel ratings and aggregate current.

Load Condition Specified Current Rating
Single Point at 30°C 1.5 A maximum continuous current
Single Point at 55°C 1.0 A maximum continuous current
Entire Module 6.4 A maximum at 0–60°C

Important: The 6.4 A module limit applies to aggregate loading. Sixteen channels cannot simultaneously operate at their individual maximum ratings.

For example, engineers should calculate the combined current of energized solenoids and relay coils. They should also consider simultaneous switching and startup conditions.

Maintain sufficient electrical margin below the applicable channel and module limits. Verify the manufacturer's load derating requirements before finalizing the circuit design.

Switching Response and Signal Integrity

The module provides defined output switching delays for discrete control applications.

Performance Parameter Value
OFF-to-ON Delay 1.0 ms
ON-to-OFF Delay 0.1 ms
OFF-State Leakage 1 mA

The low off-state leakage current matters when connecting sensitive electronic loads. Some devices may respond to small residual currents.

For relay interfaces and electronic actuators, verify the load's minimum operating current. Consider interposing relays when the field device requires different electrical characteristics.

Backplane Power and Thermal Management

The 1746-OB16 receives its internal power through the SLC 500 chassis backplane. Its specified backplane current is 135 mA at 5.1 VDC.

  • Backplane Loading: Include 135 mA in the chassis power budget.
  • Heat Dissipation: Account for approximately 7.6 W in cabinet thermal calculations.
  • Ambient Temperature: Maintain the operating environment between 0°C and 60°C.
  • Current Derating: Apply the specified temperature-dependent output ratings.
  • Cabinet Ventilation: Prevent excessive heat accumulation around installed modules.

High-density output applications require careful thermal planning. Evaluate simultaneous channel operation rather than relying on individual output ratings alone.

Installation Guide | SLC 500 Chassis Integration

  1. Verify the Catalog Number: Confirm the module label reads 1746-OB16.
  2. Check Chassis Compatibility: Verify the selected SLC 500 chassis configuration.
  3. Inspect Power Capacity: Calculate the available backplane current budget.
  4. Isolate System Power: Follow applicable electrical safety procedures.
  5. Install the Module: Insert it into the designated compatible chassis slot.
  6. Prepare Field Wiring: Identify all 16 output channels and common connections.
  7. Verify Polarity: Confirm positive supply and load-return connections.
  8. Check Load Ratings: Calculate individual and aggregate current requirements.
  9. Restore Power: Inspect controller and module operating status.
  10. Test Each Channel: Confirm correct switching at representative field loads.

Safety Note: Always isolate electrical power before wiring or replacing the module. Follow Rockwell Automation installation instructions.

Commissioning and Field Maintenance

Effective commissioning verifies the electrical interface and actual load response. The following checks help identify common installation problems.

  • Voltage Check: Measure field supply voltage under operating conditions.
  • Channel Verification: Test all 16 output points individually.
  • Current Measurement: Compare measured load current with rated limits.
  • Switching Test: Verify output transitions and connected device response.
  • Leakage Assessment: Investigate unexpected load activation when outputs remain OFF.
  • Thermal Inspection: Check cabinet temperature during extended operation.
  • Terminal Inspection: Look for loose connections and signs of overheating.
  • Documentation: Record channel assignments and field wiring changes.

For inductive loads, inspect suppression components and wiring arrangements. These components help manage switching transients and protect connected equipment.

Compatibility and System Integration

Integration Item Technical Consideration
PLC Platform Allen-Bradley SLC 500
Chassis Compatible 1746-series chassis
Output Interface 16-point DC sourcing output
Field Supply Nominal 24 VDC
Output Load Compatible DC loads
Backplane Supply 5.1 VDC internal power interface
Replacement Selection Verify output type, voltage, current, and terminal assignments

The 1746-OB16 belongs to the SLC 500 1746 I/O family. It requires a compatible chassis and appropriate field wiring.

Do not substitute sinking output modules without reviewing the complete electrical design. Similar channel counts do not guarantee equivalent load compatibility.

Environmental and Certification Considerations

  • Operating Temperature: 0°C to 60°C.
  • Output Voltage: 10–50 VDC specified range.
  • Nominal Application Voltage: 24 VDC.
  • Heat Dissipation: 7.6 W.
  • Installation Environment: Suitable industrial control enclosure.
  • Certifications: Confirm applicable approvals against the exact catalog revision and manufacturer documentation.

Verify applicable EMC, electrical safety, and environmental requirements before installation. Do not assume an IP rating or hazardous-area approval without supporting documentation.

Packaging and Supply Information

  • Manufacturer: Rockwell Automation
  • Brand: Allen-Bradley
  • Catalog Number: 1746-OB16
  • Series: SLC 500
  • Product: 16-Point Digital DC Output Module
  • Warranty: 12 months
  • Shipping Options: DHL, FedEx, and UPS

Standard shipment includes one 1746-OB16 output module with protective packaging. Confirm any additional accessories or documentation before ordering.

Frequently Asked Questions | Engineering Applications

Q1: Why can an output indicator show an active state while the field device remains inactive?

An active indication does not always confirm successful load operation. Check the field supply, output terminal voltage, common wiring, and load continuity. A disconnected return path can prevent the device from operating correctly.

Q2: How should engineers handle relay coils connected to solid-state outputs?

Verify the coil's rated voltage and pickup current first. Check its inductive switching characteristics. Install suitable suppression components when required. Confirm that suppression does not interfere with the required release time.

Q3: What causes a field device to remain energized after the PLC switches an output OFF?

Possible causes include off-state leakage, incorrect wiring, external backfeed, or a faulty load interface. Measure voltage at the output and load terminals. Check the device's minimum operating threshold before identifying the module as defective.

Q4: Why is aggregate current more important than simply checking each output channel?

Individual channels may remain within their ratings while total module loading exceeds its limit. This condition can increase thermal stress and affect long-term reliability. Calculate the simultaneous load current across all energized channels.

Q5: What information should maintenance teams record after replacing this module?

Record the catalog number, chassis slot, terminal assignments, field voltage, and connected load current. Also document controller configuration changes and commissioning results. These records simplify future troubleshooting and replacement planning.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.