Yokogawa AAR181-S00 RTD Input Module CENTUM VP | Buy Online
Manufacturer: Yokogawa
Product No.: AAR181-S00
Condition: In stock
Product Type: RTD Input Module
Product Origin: SG
Payment: T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview
The Yokogawa AAR181-S00 standard 12-channel isolated RTD input module delivers high-accuracy temperature measurements for process control applications. Engineered for the Yokogawa CENTUM VP control system, this module conditions and digitizes signals from 3-wire Pt100 sensors. It isolates process signals from core system electronics to maintain high data integrity in noisy industrial environments.
Technical Specifications (MECE Categorization)
1. Basic Identification
- Brand: Yokogawa
- Model: AAR181-S00
- Series: CENTUM VP / CENTUM CS 3000 I/O System
- Module Type: 12-Channel Isolated RTD Input Module
2. Electrical & Performance Characteristics
| Parameter | Specification Standard |
|---|---|
| Input Channels | 12 isolated channels (CH1 to CH12) |
| Input Signal Standard | Pt100 (3-wire type) matching JIS C1604:1997 and IEC751:1995 |
| Measurement Range | -200°C to +850°C (standard Pt100 sensor limits) |
| Accuracy | ±120 mΩ for RTD input |
| Resolution | 16-bit A/D conversion |
| Linearity | ±0.05% of full scale |
| Sensitivity | 0.0385 Ω/°C nominal (Pt100 standard curve) |
| Excitation Current | 1 mA constant current source |
| Frequency Response | 1 Hz filter cut-off (optimized for 1 s data refresh) |
| Data Update Period | 1 second (all channels processed) |
| Input Resistance | ≥ 2 MΩ (Power ON and Power OFF state) |
| Allowable Input Voltage | ±5 V DC maximum |
| Allowable Wire Resistance | ≤ 40 Ω per wire (total signal source + wiring) |
| Temperature Drift | ±120 mΩ per 10°C ambient change |
| Power Consumption | 450 mA maximum at 5 V DC system bus supply |
3. Protection & Environmental Immunity
- Withstanding Voltage: 1500 V AC between input terminals and system ground for 1 minute.
- Anti-Interference: Optical isolation eliminates ground loops and line-frequency common-mode noise.
- Operating Temperature Range: 0°C to 60°C operational ambient limit.
- Storage Temperature Range: -20°C to 70°C ambient storage limits.
- Environmental Tolerance: G3 harsh environment coating standard for industrial atmospheric resistance.
4. Physical & Installation Specifications
- Connection Type: Dedicated pressure clamp terminal block for rapid wiring.
- Physical Weight: 0.2 kg net weight.
- Mounting Configuration: Direct mounting into Yokogawa I/O node units.
5. Compliance & Certifications
- CE Mark: Complies with EMC Directive directives.
- CSA/UL Safety: Certified for industrial control equipment safety standards.
- Standards Met: JIS C1604:1997 and IEC 751:1995 for platinum resistance thermometers.
Diagnostic & Burn-Out Capabilities
The AAR181-S00 module features configurable open-circuit burn-out detection for all 12 channels. Engineers can enable or disable UP/DOWN direction alerts across channels. The module detects open sensor wires or damaged elements within 60 seconds. Internal diagnostic logic continuously reports channel faults to the Yokogawa CENTUM VP system software.
Installation & Wiring Guidelines
Always power down the system rack before inserting or removing the AAR181-S00 unit. Connect 3-wire Pt100 RTDs to the pressure clamp terminal block using equal-length conductors. Keep total wire resistance under 40 Ω per line to preserve measurement accuracy. Route field cables away from high-voltage lines to maintain high signal noise immunity.
Maintenance & Field Troubleshooting
The module requires no routine manual calibration due to solid-state design. If a channel flags a burn-out alarm, measure field resistance using a calibrated multimeter. Verify that wiring resistance matches across all three legs to prevent measurement offset. Hot-swap procedures require proper engineering station maintenance overrides prior to module physical extraction.
System Compatibility
The Yokogawa AAR181-S00 integrates directly with Yokogawa CENTUM VP field control units (FCU). It also supports CENTUM CS 3000 nodes utilizing matching baseplates. Use standard Yokogawa engineering software tools to configure channel parameters and alarm thresholds.
Typical Application Scenarios
- Distillation column tray temperature tracking in chemical plants.
- Boiler feed-water loop monitoring in power plants.
- Reactor vessel temperature profile surveillance in refining operations.
- Storage tank ambient and product thermal monitoring.
Package Contents & Logistics
- Package Checklist: 1x Factory Sealed Yokogawa AAR181-S00 RTD Input Module, 1x Installation Quick Guide.
- Warranty Terms: Complete 12-month comprehensive warranty covering functional defects.
- Dispatch Timeframe: Fast 24-48 hour order processing and shipping.
- Shipping Carriers: Express worldwide delivery via FedEx, UPS, or DHL.
Global PLC Spare HUB's Insight & Field Experience
Our automation engineering field teams often inspect temperature drop issues in 3-wire RTD loops. In one petrochemical project, a customer reported a 3°C temperature drift on a AAR181-S00 channel. Our field diagnosis revealed that terminal corrosion added 8 Ω to line A while line B stayed clean. Balancing lead resistances immediately restored the module to its specified ±120 mΩ precision. We recommend checking terminal clamp torque yearly in high-vibration plants.
Selection & Buyer's Guide
Verify your field sensor type before selecting the AAR181-S00. This module exclusively accepts 3-wire Pt100 RTDs (JIS/IEC standard). If your process relies on 2-wire RTDs or thermocouples, consider the Yokogawa AAT145 or alternative analog modules. For high-density, basic industrial installations, the 12-channel isolated design of the AAR181-S00 provides optimal cost per channel.
Frequently Asked Questions (FAQ)
Q: Does the AAR181-S00 support 2-wire or 4-wire RTD sensors directly?
A: The module is optimized specifically for 3-wire Pt100 RTDs. 2-wire sensors can work by jumpering terminals, but wire resistance compensation will be disabled.
Q: How fast does the module detect a broken wire or open RTD sensor?
A: The integrated diagnostic burn-out detection circuit flags open wires within a maximum time of 60 seconds.
Q: What causes temperature measurement errors on single channels during operation?
A: Unbalanced wire resistance across the 3 conductors is the main cause. Ensure all three wire paths stay under 40 Ω total resistance.
Q: What is the benefit of the 1500 V AC withstanding isolation rating?
A: It prevents electrical transients and ground loops from damaging the central Yokogawa CENTUM system backplane processor components.
Q: What express shipping options are available for urgent plant downtime?
A: We offer 24-48 hour dispatch options using FedEx, UPS, and DHL express international services worldwide.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.