The Schneider Electric Modicon Quantum 140DIO33000 discrete output module delivers reliable intrinsically safe digital switching.
Engineers design this module specifically for explosive gas and dust environments across modern process industries.
It interfaces low-power control electronics with field devices located in Zone 20, 21, and 22 hazardous areas.
The unit features eight open collector outputs with precise 24 V DC voltage regulation.
Solid-state switching eliminates mechanical contact wear and extends overall operational life.
Technical Specifications
| Category | Specification Parameter | Technical Value |
|---|---|---|
| Identity & Hardware Architecture | Brand & Series | Schneider Electric Modicon Quantum |
| Identity & Hardware Architecture | Model Number | 140DIO33000 |
| Identity & Hardware Architecture | Module Format & Weight | Standard Quantum Slot / 0.99 lb (0.45 kg) |
| Electrical Output Characteristics | Discrete Output Voltage & Type | 24 V DC / Open Collector |
| Electrical Output Characteristics | Channel Resolution & Density | 8 Intrinsically Safe Points |
| Electrical Output Characteristics | Current Capacity per Point / Module | 45 mA per point / 360 mA total module load |
| Electrical Output Characteristics | Off-State Leakage Current | 0.4 mA maximum per point |
| Electrical Output Characteristics | Backplane Bus Current & Power Dissipation | 2.2 A bus requirement / 5 W dissipation |
| Signal Dynamics & Isolation | Response Time (State 0 to 1 / 1 to 0) | 1 ms resistive (turn-on) / 1 ms resistive (turn-off) |
| Signal Dynamics & Isolation | Dielectric Isolation Rating | 2500 V DC for 1 minute / 1780 V AC at 47-63 Hz |
| Environmental & Noise Immunity | Operating & Storage Temperature | 32°F to 140°F (0°C to 60°C) / -40°F to 185°F (-40°C to 85°C) |
| Environmental & Noise Immunity | Relative Humidity & Altitude Limit | 95% non-condensing / Up to 16,404 ft (5000 m) |
| Environmental & Noise Immunity | Electrostatic Discharge (ESD) Immunity | 4 kV contact / 8 kV air (IEC 801-2) |
| Environmental & Noise Immunity | Electromagnetic Field Resistance | 9.1 V/m (10 V/m) at 80 to 2000 MHz (IEC 801-3) |
Installation Guide
- Turn off backplane power prior to inserting the module into the Quantum rack.
- Verify intrinsic safety barrier wiring protocols according to EN 50020 standard guidelines.
- Route intrinsically safe field cables separately from standard power lines to prevent coupling.
- Ensure proper grounding of the module chassis to maintain full ESD shielding performance.
- Do not perform hot swapping during operation per intrinsic safety compliance mandates.
Commissioning & Maintenance
- Inspect internal fuse integrity prior to powering up the automation rack system.
- Use calibration meters to verify 24 V DC voltage output across active field circuits.
- Check off-state leakage current to ensure values remain below 0.4 mA per point.
- Perform routine visual checks on terminal block wire contacts and chassis latch points.
System Compatibility
- Compatible with Schneider Electric Modicon Quantum automation backplanes.
- Supported in Concept V2.2 and above programming software packages.
- Fully functional with ProWORX 32 programming and configuration utilities.
- Seamlessly integrates into EcoStruxure Control Expert (Unity Pro) software environments.
- Operates alongside field devices rated for Zone 20, 21, or 22 hazardous areas.
Certifications & Compliance
| Certification Body / Directive | Compliance Standard Details |
|---|---|
| ATEX Directive | Directive 94/9/EC / SIRA 02ATEX2345X |
| Hazardous Area Marking | CE II1 G/D-EEx ia IIC / FM Class 1 Division 2 |
| European Electrical Standards | EN 50014, EN 50020, EN 50039, EN 50028, EN 50281-1-1, EN 50284 |
| North American Safety Standards | UL 508 / CSA C22.2 No 142 |
| International Certifications | C-tick / GOST |
Typical Application Scenarios
- Controlling solenoid valves in chemical processing plants located inside hazardous areas.
- Operating alarm annunciators in oil and gas offshore processing platforms.
- Actuating discrete relay coils in pharmaceutical powder handling environments.
- Managing field indicator lamps in grain handling storage facilities with explosive dust.
Diagnostic Capabilities
- Transient voltage suppression circuits guard output channels against severe inductive spikes.
- Internal fuses protect internal backplane connections from external overcurrent faults.
- Real-time LED indicators report logic-side power states and individual channel signal activity.
- Software diagnostic flags detect open-circuit line faults and supply power drops instantly.
Package Contents & Logistics
| Item Parameter | Detail Information |
|---|---|
| Package Dimensions | 12.40 in x 6.50 in x 1.97 in (31.5 cm x 16.5 cm x 5.0 cm) |
| Package Gross Weight | 1.545 lb (0.701 kg) |
| Warranty Term | 12 Months Comprehensive Coverage |
| Dispatch Speed | Shipped within 24 to 48 hours |
| Shipping Express Carriers | FedEx, UPS, DHL express delivery options available worldwide |
Global PLC Spare HUB's Insight
Our automation engineers often encounter field issues caused by improper cable separation in intrinsically safe installations.
During a chemical plant upgrade, field technicians experienced ghost triggering on output channels.
The team traced the interference to adjacent 230 V AC motor lines running inside the same conduit.
Installing the Modicon Quantum 140DIO33000 with dedicated shielded wiring resolved all electrical noise problems immediately.
Its robust 2500 V DC isolation and 10 V/m noise resistance ensured completely stable output switching.
Frequently Asked Questions
Question: Can I hot swap the 140DIO33000 module while the rack is energized?
Answer: No, standard safety regulations prohibit hot swapping intrinsically safe modules to prevent electrical sparking risks.
Question: What cable distance is recommended for 24 V DC open collector outputs?
Answer: Field experience indicates keeping cable lengths under 300 meters minimizes line resistance and signal degradation.
Question: How do I select between the 140DIO33000 and standard discrete output modules?
Answer: Choose the 140DIO33000 whenever field actuators sit in hazardous Zone 20, 21, or 22 environments requiring ATEX certification.
Question: What programming software supports configuration of this output card?
Answer: You can configure this card using Unity Pro, Concept V2.2 or higher, and ProWORX software platforms.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.