Precision Position Feedback for Demanding Motion Systems

Renishaw RGH22Y30D61A is a non-contact optical encoder readhead from the RGH22 series. It provides reliable position feedback for precision linear motion applications. Its open optical architecture eliminates mechanical contact between the readhead and scale.

The readhead operates with the RGS20-S gold tape scale, which features a 20 μm incremental pitch. Integrated interpolation supports resolutions down to 50 nm, depending on the output configuration. Engineers can select compatible analogue or digital signal interfaces for their motion controllers.

Several practical features simplify machine integration. An integral setup LED assists optical alignment. Specialized filtering optics improve resistance to contamination. Integrated reference and limit sensors also reduce the need for separate sensing components.

01 | Product Identity & Configuration Breakdown

Brand Renishaw
Complete Model RGH22Y30D61A
Product Family RGH22
Product Type Non-contact Optical Encoder Readhead
Measurement Technology Incremental Optical Position Feedback
Compatible Scale RGS20-S Gold Tape Scale
Scale Pitch 20 μm
Connector Configuration D – 15-way D-sub connector
Readhead Mass Approximately 45 g
Country of Manufacture Not specified in the supplied documentation

Model Configuration Reference

  • RGH22
    • Identifies the RGH22 non-contact optical encoder readhead family.
    • Supports incremental position measurement with integrated interpolation.
  • Y
    • Identifies the specified RGH22 variant.
    • Confirm the exact electrical output and resolution against the manufacturer's ordering documentation.
  • 30
    • Configuration code within the complete ordering reference.
    • Its precise meaning requires the manufacturer's model-code definition.
  • D
    • 15-way D-sub connector configuration.
  • 61A
    • Remaining ordering configuration suffix.
    • Confirm its electrical and mechanical definitions before selecting a replacement.

Configuration Note: The suffix breakdown above distinguishes the supplied connector information from codes requiring further manufacturer documentation. It does not assume undocumented electrical characteristics.

02 | Optical Measurement & Signal Performance

Measurement Method Non-contact optical incremental encoding
Compatible Scale RGS20-S gold tape scale
Scale Pitch 20 μm
Interpolation Integrated interpolation
Resolution Capability 5 μm to 50 nm across the RGH22 range
Output Options 1 Vpp analogue or RS422 digital, depending on configuration
Reference Sensor Integrated
Limit Sensors Integrated
Setup Assistance Integral LED indicator
Optical Protection Specialized filtering optics

Engineering Interpretation: The 50 nm figure represents the finest resolution capability stated for the RGH22 family. It should not be interpreted as absolute measurement accuracy or guaranteed system repeatability. Actual performance depends on the readhead variant, scale installation, controller interface, and mechanical system.

03 | Electrical Interface & Power Requirements

Supply Voltage 5 V DC ±5%
Typical Current Consumption 200 mA for RGH22Y
Power Supply Standard SELV requirements, IEC BS EN 60950-1
Maximum Supply Ripple 200 mVpp at frequencies up to 500 kHz
Digital Output Options RS422 differential signals
Analogue Output Options 1 Vpp signals
Digital Termination Current Additional 25 mA per terminated channel pair at 120 Ω
Analogue Termination Current Additional 20 mA with 120 Ω termination
Connector 15-way D-sub

Power Design Consideration: Current consumption figures refer to unterminated readheads. Digital and analogue termination conditions introduce additional current requirements. Size the 5 V supply according to the actual interface configuration.

04 | Cable Construction & Mechanical Durability

  • Conductors: 12-core cable.
  • Shielding: Double-shielded construction.
  • Maximum Cable Diameter: 4.7 mm.
  • Flex Life: More than 20 × 10⁶ cycles.
  • Test Bend Radius: 50 mm.
  • Readhead Mass: 45 g.
  • Cable Mass: 38 g/m.

The flexible cable supports repeated movement in dynamic machine installations. Double shielding helps reduce susceptibility to electrical interference. Maintain the specified bend radius during cable routing to protect conductor integrity.

05 | Environmental & Operating Limits

Operating Temperature 0°C to +55°C
Storage Temperature -20°C to +70°C
Relative Humidity Up to 95%, non-condensing
Humidity Standard EN 60068-2-78
Ingress Protection IP50
Operating Acceleration 500 m/s², 3 axes
Operating Vibration 100 m/s² maximum, 55 Hz to 2000 Hz, 3 axes
Non-operating Shock 1000 m/s², 6 ms, half-sine, 3 axes

Installation Environment: IP50 protection does not provide protection against water ingress. Avoid condensation, liquid exposure, and heavy airborne contamination. Use suitable machine guarding when the installation environment requires additional protection.

06 | Installation & Optical Alignment

Step 1 – Scale Preparation

Clean the mounting substrate before applying the RGS20-S scale. Check the mounting surface for flatness and contamination. Select a substrate compatible with the scale installation method.

Step 2 – Scale Mounting

The RGS20-S uses a specially formulated pre-applied adhesive. Epoxy-fastened end clamps secure the scale. This mounting arrangement minimizes differential movement between the scale and substrate during temperature changes.

Step 3 – Readhead Positioning

Position the RGH22 readhead according to the manufacturer's optical and mechanical alignment specifications. Maintain the required readhead-to-scale relationship. Avoid mechanical contact with the scale during axis movement.

Step 4 – LED Setup Verification

Use the integral setup LED during alignment. Check the indicator according to the manufacturer's installation procedure. Correct optical positioning before finalizing the mounting arrangement.

Step 5 – Electrical Connection

Connect the 15-way D-sub interface to the compatible controller or signal-processing equipment. Verify the 5 V supply polarity and voltage. Check output-interface compatibility before applying power.

Step 6 – Motion Validation

Move the axis slowly through its operating range. Confirm incremental signal stability and reference sensor operation. Check limit sensor responses where the machine configuration uses them.

07 | Engineering Applications & Integration Advantages

  • Metrology Equipment: Provides incremental position feedback for precision measuring systems.
  • Semiconductor Manufacturing: Supports controlled positioning in precision motion assemblies.
  • Flat Panel Display Production: Provides position feedback for automated linear stages.
  • Electronics Manufacturing: Supports repeatable motion control in automated production equipment.
  • Linear Motion Systems: Integrates optical feedback into compatible machine axes.

The open optical architecture avoids mechanical contact between the readhead and scale. Filtering optics improve tolerance to dirt contamination. Integrated interpolation reduces the need for separate external interpolation hardware.

08 | Compatibility & Purchasing Considerations

Before selecting RGH22Y30D61A, engineers should verify the following integration details:

  • Confirm compatibility with the RGS20-S 20 μm gold tape scale.
  • Match the output type to the motion controller input.
  • Verify the 15-way D-sub connector arrangement.
  • Check the 5 V DC power supply capacity.
  • Confirm the required interpolation resolution.
  • Check reference and limit sensor requirements.
  • Verify cable routing and minimum bend radius.
  • Confirm mounting geometry and environmental limits.

Replacement Recommendation: When replacing an existing Renishaw encoder, compare the complete part number rather than relying on the RGH22 series designation alone. Output format, connector arrangement, resolution, and scale compatibility determine successful integration.

09 | Quality Assurance & Warranty

  • Warranty: 12 months.
  • Model Verification: Part number and configuration checks before order confirmation.
  • Application Support: Assistance with encoder selection and compatibility verification.
  • Shipping Options: FedEx, UPS, and DHL.
  • Application Areas: Precision motion control, metrology, semiconductor, and electronics manufacturing.

Contact our team to confirm product availability, configuration details, and purchasing requirements.

10 | Frequently Asked Questions

Q1: Why does an optical encoder require a reference position during machine startup?

An incremental encoder measures relative movement rather than automatically identifying an absolute machine coordinate. The controller typically performs a reference operation to establish the machine origin. The integrated reference sensor supports this process.

Q2: How does scale mounting affect positioning accuracy over long travel distances?

Scale mounting stability directly influences the relationship between measured position and actual axis movement. Thermal expansion differences can introduce measurement errors. The RGS20-S adhesive and end-clamp arrangement helps minimize differential movement relative to the substrate.

Q3: What maintenance action is most useful when optical signal quality deteriorates?

Inspect the scale surface and readhead alignment before replacing electronic components. Check for oil films, dust accumulation, mechanical movement, and damaged cable shielding. Use the setup LED to assist alignment checks.

Q4: Should engineers select 50 nm resolution for every precision motion application?

No. Higher resolution does not automatically improve overall positioning accuracy. Evaluate machine stiffness, guideway performance, controller interpolation, scale installation, and feedback bandwidth. Select resolution according to the complete motion-control system.

Q5: What information should buyers provide when sourcing an RGH22 replacement?

Provide the complete readhead model, existing scale reference, output interface, connector type, and required resolution. Include the controller model when possible. These details help verify electrical and mechanical compatibility before procurement.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.