Q4BCW30D12A Renishaw QUANTiC Linear Encoder Readhead
Manufacturer: Renishaw
Product No.: Q4BCW30D12A
Condition: In stock
Product Type: Encoder Readhead
Product Origin: UK
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Renishaw QUANTiC™ | Digital Position Feedback for Precision Linear Motion
Q4BCW30D12A is a digital incremental optical encoder readhead from the Renishaw QUANTiC™ Q4 series. It provides precise position feedback for industrial linear motion systems.
This configuration combines a 40 μm scale pitch, 0.2 μm digital resolution, and a 12 MHz clocked output. Its 3-meter cable terminates with a 15-way D-type connector. The readhead supports compatible RTLC40, RTLC40-S, and RKLC40-S linear scales.
The QUANTiC architecture integrates optical sensing, signal processing, and reference mark functionality. It supports accurate incremental position measurement in demanding automation environments. Engineers can integrate this encoder into precision stages, measuring equipment, and automated positioning systems.
01 | Product Identity & Configuration Architecture
| Manufacturer | Renishaw |
| Complete Model | Q4BCW30D12A |
| Product Series | QUANTiC™ Q4 |
| Product Type | Digital Incremental Optical Linear Encoder Readhead |
| Measurement Method | Non-contact optical incremental measurement |
| Scale Pitch | 40 μm |
| Digital Resolution | 0.2 μm (200 nm) |
| Cable Length | 3 meters |
| Connector | 15-way D-type plug, standard pin-out |
| Clocked Output | 12 MHz |
| Reference Mark | Customer selectable |
| Alarm Format | Line-driven alarm |
02 | Part Number Breakdown – Decode Every Configuration
The complete ordering code identifies the encoder's mechanical, optical, electrical, and signal configurations.
| Code | Configuration | Engineering Description |
|---|---|---|
| Q4 | Series | QUANTiC 40 μm encoder family |
| B | Readhead Type | Standard linear readhead |
| C | Scale Compatibility | RTLC40 / RTLC40-S / RKLC40-S |
| W | Digital Resolution | 0.2 μm (200 nm) |
| 30 | Cable Length | 3 meters |
| D | Connector | 15-way D-type plug, standard pin-out |
| 12 | Clocked Output | 12 MHz |
| A | Reference / Alarm | Customer selectable reference mark and line-driven alarm |
Complete Configuration:
Q4 → 40 μm QUANTiC series
└── B → Linear readhead
└── C → RTLC40-compatible scale configuration
└── W → 0.2 μm digital resolution
└── 30 → 3 m cable
└── D → 15-way D-type standard pin-out
└── 12 → 12 MHz clocked output
└── A → Selectable reference mark / line-driven alarm
This configuration structure helps engineers distinguish electrical interface requirements from scale compatibility and resolution options.
03 | Optical Measurement & Digital Signal Characteristics
| Encoder Technology | Optical incremental encoding |
| Readhead Architecture | Non-contact optical system |
| Scale Pitch | 40 μm |
| Digital Resolution | 0.2 μm |
| Clock Frequency | 12 MHz |
| Output Type | Digital incremental, RS422 interface family |
| Reference Function | Customer selectable reference mark |
| Alarm Function | Line-driven alarm output |
| Scale Reading | Compatible 40 μm linear scale |
Resolution and Accuracy: The 0.2 μm value represents the configured digital position resolution. It does not represent absolute measurement accuracy. Actual positioning performance also depends on scale installation, machine geometry, controller processing, and mechanical stability.
04 | Scale Compatibility & Mechanical Integration
The Q4BCW30D12A is designed for the following 40 μm linear scale configurations:
- RTLC40: Compatible 40 μm linear scale.
- RTLC40-S: Compatible 40 μm stainless steel scale.
- RKLC40-S: Compatible 40 μm steel tape scale.
These scale options provide different mechanical installation possibilities. Select the scale according to travel length, substrate material, mounting geometry, and environmental conditions.
Before installation, verify the scale's mechanical condition and mounting reference. Check the readhead alignment against the manufacturer's specified installation tolerances.
05 | Reference Mark & Alarm Configuration
Customer Selectable Reference Mark
The A configuration supports reference mark selection. A selector magnet activates the required reference position. This function is useful when a scale contains multiple IN-TRAC reference marks.
Engineers can select a specific reference position for machine homing. This arrangement supports applications with multiple possible reference locations.
Line-Driven Alarm
The configured alarm output uses a line-driven format. It provides an alarm indication when the encoder detects an applicable signal condition. The receiving controller must support the corresponding alarm interface.
Important: Only the calibrated reference mark provides bidirectional repeatability. Follow the manufacturer's reference mark setup procedure during commissioning.
06 | Installation & Commissioning Workflow
Stage 1 – Mechanical Preparation
- Inspect the linear scale and mounting substrate.
- Remove contamination from the installation surface.
- Check the scale position and mounting stability.
- Verify the readhead mounting arrangement.
Stage 2 – Optical Alignment
- Position the readhead according to Renishaw installation instructions.
- Maintain the specified readhead-to-scale relationship.
- Check the optical signal during initial alignment.
- Secure the readhead after confirming alignment.
Stage 3 – Electrical Connection
- Confirm the 15-way D-type connector configuration.
- Check the controller's RS422 interface compatibility.
- Verify the required 12 MHz clocked output support.
- Confirm the reference and alarm input assignments.
Stage 4 – Functional Testing
- Move the axis through a controlled travel distance.
- Verify incremental counting and direction detection.
- Test the selected reference mark response.
- Check alarm signal recognition at the controller.
- Compare encoder feedback against an independent position reference.
07 | Maintenance & Diagnostic Recommendations
- Position Drift: Check scale mounting stability and machine thermal behavior.
- Signal Interruption: Inspect the cable, connector, and controller interface.
- Incorrect Homing: Verify selector magnet position and reference mark configuration.
- Unexpected Alarm: Check optical alignment and alarm input wiring.
- Counting Errors: Review signal integrity, controller clock compatibility, and scale condition.
Regular inspection helps maintain stable encoder feedback. Avoid unnecessary mechanical adjustments before checking electrical signals and alignment conditions.
08 | Engineering Applications
- Precision Linear Stages: Provides incremental position feedback for controlled axis movement.
- CNC Equipment: Supports accurate feedback in compatible linear positioning systems.
- Metrology Machines: Supplies digital position information for measurement equipment.
- Semiconductor Equipment: Supports precision positioning in automated production systems.
- Automated Inspection Systems: Provides repeatable position feedback for scanning and inspection axes.
- Industrial Motion Platforms: Integrates with compatible digital motion controllers.
09 | Compatibility & Replacement Selection
When selecting a replacement for an existing encoder, verify these five engineering parameters:
- Scale Pitch: Confirm the existing scale uses a 40 μm pitch.
- Resolution: Match the required 0.2 μm digital resolution.
- Connector: Verify the 15-way D-type standard pin-out.
- Clocked Output: Confirm controller support for 12 MHz.
- Reference Configuration: Verify customer selectable reference marks and line-driven alarm requirements.
Do not replace an encoder based only on the QUANTiC series name. Different readhead configurations can have different resolutions, connectors, clock frequencies, and reference options.
10 | Warranty, Quality & Global Shipping
| Warranty Period | 12 months |
| Product Verification | Model and configuration verification |
| Technical Support | Product selection and compatibility assistance |
| Shipping Carriers | FedEx, UPS, DHL |
| Application Support | Industrial automation and precision motion systems |
Our team supports industrial encoder procurement and replacement projects. Contact us to confirm the exact model configuration, availability, and quotation details.
11 | Frequently Asked Questions
Q1: What is the difference between incremental and absolute encoder feedback?
An incremental encoder measures relative movement through digital signal transitions. The controller establishes the machine coordinate through a reference procedure. An absolute encoder provides a coded position value without requiring the same incremental homing process.
Q2: Why must the controller support the encoder's clock frequency?
The clocked output configuration affects signal communication and processing compatibility. An incompatible controller interface may fail to decode the encoder signals correctly. Verify the 12 MHz specification against the controller's supported input requirements.
Q3: When should engineers use a selectable reference mark instead of outputting every reference mark?
A selectable reference mark suits applications with multiple reference locations. It allows a designated reference position to be activated through a selector magnet. Applications with one reference position may use an all-reference-mark configuration instead.
Q4: How can engineers determine whether a replacement readhead will work with an existing scale?
Check the scale pitch, scale family, readhead compatibility code, and mounting arrangement. The 40 μm pitch alone does not establish complete compatibility. Confirm the valid readhead and scale combination using Renishaw system configuration documentation.
Q5: What should buyers consider when choosing between 0.2 μm and finer encoder resolutions?
Evaluate the required positioning tolerance and the machine's mechanical performance. Finer resolution increases the number of reported position increments. However, it cannot compensate for backlash, structural deformation, thermal expansion, or poor scale installation. Select the resolution according to the complete machine specification.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.