Home Renishaw RGH22B50L00A Linear Optical Encoder Readhead

Renishaw RGH22B50L00A Linear Optical Encoder Readhead

  • Manufacturer: Renishaw

  • Product No.: RGH22B50L00A

  • Condition: In stock

  • Product Type: Encoder Readhead

  • Product Origin: UK

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Product Overview

The Renishaw RGH22B50L00A is a non-contact optical linear encoder readhead. It belongs to the RGH22 series within the RG2 incremental encoder system.

This readhead provides 1 Vpp differential analogue output for precision linear position feedback. It operates with the 20 µm pitch RGS20-S reflective steel scale.

The RGH22B configuration includes a single limit sensor and an integrated reference mark sensor. Its open optical design supports non-contact position measurement without mechanical contact with the scale.

The integrated set-up LED helps engineers check installation alignment. Internal signal interpolation supports stable position feedback in motion control applications.

The 5 m cable and 15-way D-type connector simplify integration with compatible controller interfaces. The standard 00A configuration provides the specified factory connection arrangement.

Key Features

  • Optical measurement: Non-contact incremental linear position detection.
  • Signal output: 1 Vpp differential analogue signals.
  • Scale compatibility: 20 µm pitch RGS20-S reflective steel scale.
  • Limit detection: Integrated single limit sensor.
  • Reference positioning: Integrated reference mark detection.
  • Installation support: Built-in multicolour set-up LED.
  • Cable assembly: 5 m, 12-core, double-shielded cable.
  • Connector: 15-way D-type plug.

Technical Specifications

Parameter Specification
Brand Renishaw
Model RGH22B50L00A
Product Series RGH22 / RG2
Product Type Open Optical Linear Encoder Readhead
Measurement Principle Non-contact optical incremental measurement
Output Type 1 Vpp differential analogue
Scale Compatibility RGS20-S reflective steel tape scale
Scale Pitch 20 µm
Limit Configuration Single limit sensor
Reference Mark Integrated reference mark sensor
Cable Length 5 m
Cable Construction 12-core, double-shielded, high-flexibility cable
Maximum Cable Diameter 4.7 mm
Connector Type 15-way D-type plug
Configuration 00A Standard
Supply Voltage 5 V DC ±5%
Typical Current Consumption 120 mA, unterminated readhead
Additional Termination Current Approximately 20 mA with 120 Ω analogue termination
Maximum Analogue Readhead Speed 4 m/s at −3 dB
Ride Height 0.8 ±0.1 mm
Operating Temperature 0 °C to +55 °C
Storage Temperature −20 °C to +70 °C
Protection Rating IP50
Operating Humidity 95% RH, non-condensing
Operating Acceleration 500 m/s², three axes
Operating Vibration 100 m/s² maximum, 55 Hz to 2000 Hz, three axes
Non-operating Shock 1000 m/s², 6 ms, half-sine, three axes
Readhead Weight 45 g, excluding cable

Measurement Performance

  • Measuring range: The scale determines the available measuring length. RGS20-S supports lengths up to 50 m.
  • Signal period: The analogue signal corresponds to the 20 µm scale pitch.
  • Maximum speed: The RGH22A/B analogue range supports up to 4 m/s at −3 dB.
  • Scale linearity: RGS20-S provides ±3 µm/m scale linearity.
  • Resolution: The analogue output does not specify one fixed digital resolution. The receiving controller determines interpolation resolution.
  • Sensitivity: The manufacturer specifies 1 Vpp differential output rather than a separate sensitivity value.
  • Frequency response: The manufacturer specifies maximum analogue speed at −3 dB. Confirm controller bandwidth before system design.

Installation Guide

Correct mechanical alignment directly affects signal quality and measurement stability.

  1. Confirm the machine uses the compatible RGS20-S 20 µm scale.
  2. Clean the mounting surface before installing the scale.
  3. Maintain the specified scale alignment with the machine travel axis.
  4. Mount the readhead using the designated fixing holes.
  5. Set the readhead ride height to 0.8 ±0.1 mm.
  6. Check the pitch and roll alignment against the installation drawing.
  7. Position the reference mark actuator correctly along the measuring axis.
  8. Position the single limit actuator within its specified sensing area.
  9. Use the integrated set-up LED to check optical alignment.
  10. Connect the 15-way D-type plug to the compatible receiving interface.
  11. Verify the 5 V DC supply before enabling machine movement.

Maintain the cable bend radius during installation. Follow the manufacturer's dynamic and static bend requirements.

Commissioning and Maintenance

  • Power verification: Check the 5 V DC supply and voltage stability.
  • Signal verification: Measure both differential analogue signal pairs.
  • Signal balance: Check signal amplitude and waveform quality during axis movement.
  • Reference testing: Confirm repeatable reference mark detection in the intended travel direction.
  • Limit testing: Verify the single limit output with its actuator.
  • Alignment inspection: Check the set-up LED and specified ride height.
  • Shielding inspection: Verify the inner and outer shield connections.
  • Mechanical inspection: Check scale adhesion, contamination and cable condition.

For electrical noise control, follow Renishaw's grounding arrangement. Connect the outer shield to machine earth. Connect the inner shield to 0 V. Keep both shields electrically isolated.

Compatibility and Application

The RGH22B50L00A requires a compatible RGS20-S optical scale. The receiving controller must support 1 Vpp differential analogue inputs.

Engineers should verify the connector pinout, supply voltage and signal termination before installation.

Typical application areas include:

  • Coordinate measuring and dimensional inspection machines.
  • Precision linear positioning systems.
  • Semiconductor and electronics manufacturing equipment.
  • Flat panel display production equipment.
  • Automated inspection and measurement systems.
  • Linear motor positioning platforms.
  • Electronics assembly and testing equipment.

Compatibility note: Do not treat digital RS422 RGH22 variants as direct electrical replacements. Their output interfaces differ from the RGH22B analogue configuration.

Environmental Resistance and Signal Integrity

The RGH22 readhead uses a double-shielded cable to support signal integrity. Its open optical design requires suitable protection from external contamination.

  • Ingress protection: IP50 protects against dust ingress at the specified test level. It does not provide water protection.
  • Electrical noise: Correct grounding and shield separation help reduce interference.
  • Vibration: The readhead supports the specified operating vibration conditions.
  • Mechanical shock: The datasheet specifies a non-operating shock limit.
  • Temperature: Maintain the readhead within its rated operating range.

Certification and Compliance

The RGH22 technical datasheet specifies electrical, environmental and mechanical operating limits.

It also references a 5 V DC supply compliant with SELV requirements under IEC BS EN 60950-1.

Specific product certification documents are not confirmed by the available model information. Please request applicable declarations and certificates when required.

Package Contents

  • 1 × Renishaw RGH22B50L00A optical encoder readhead.
  • 1 × Integrated 5 m double-shielded cable.
  • 1 × 15-way D-type connector.
  • Product identification and applicable documentation, subject to supply scope.

Note: The RGS20-S scale and mounting accessories are separate items unless the quotation explicitly includes them. Confirm the delivery scope before ordering.

Frequently Asked Questions

Q1: Which scale works with the RGH22B50L00A?

The compatible scale is the Renishaw RGS20-S reflective steel tape scale. It uses a 20 µm pitch.

Q2: Does the RGH22B50L00A provide digital RS422 output?

No. This model provides 1 Vpp differential analogue output. Select a digital RGH22 variant for RS422 signals.

Q3: Can the readhead operate without an RGS20-S scale?

No. The optical readhead requires a compatible scale for incremental position measurement.

Q4: Why does the analogue signal become unstable after installation?

First inspect ride height, optical alignment and scale cleanliness. Then check the 5 V supply, grounding and cable shielding. Incorrect termination can also affect waveform quality.

Q5: What should engineers check when replacing an existing RGH22 readhead?

Compare the complete part number, output type, cable length and connector. Also verify the limit configuration and reference mark operation.

Q6: Can a controller accept the RGH22B output directly?

Only if its input supports compatible 1 Vpp differential analogue signals. Check input impedance, bandwidth and signal conditioning requirements.

Q7: Does the 20 µm scale pitch represent the final positioning resolution?

No. The controller determines the final interpolated resolution. Check its interpolation capability and input specifications.

Q8: Does the 5 m cable support long-distance signal transmission?

The integrated cable measures 5 m. The manufacturer permits longer extension arrangements under specified shielding and wiring conditions. Consult the RGH22 installation documentation before extending the cable.

Q9: What information should buyers confirm before ordering?

Confirm the complete model number, connector, cable length and scale compatibility. Also check the controller input type and required mounting accessories.

Q10: Is the RGS20-S scale included with this readhead?

Not automatically. The readhead and scale form separate system components. Confirm the quotation and packing list before purchase.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.