Home Bently Nevada 330105-XX-XX-05-02-05 3300 XL Reverse Mount Proximity Probe

Bently Nevada 330105-XX-XX-05-02-05 3300 XL Reverse Mount Proximity Probe

  • Manufacturer: Bently Nevada

  • Product No.: 330105-XX-XX-05-02-05 165931-01

  • Condition: In stock

  • Product Type: Proximity Probe

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 320g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Product Introduction

The Bently Nevada 330105-XX-XX-05-02-05 is a 3300 XL 8 mm Reverse Mount Proximity Probe. It measures shaft displacement in rotating machinery. Its reverse-mount configuration supports installations with specific mechanical clearance requirements.

The probe uses an eddy-current sensing principle to detect the gap between its tip and a conductive target. A compatible Proximitor processes the signal for machinery condition monitoring. Typical applications include turbines, compressors, pumps, and other critical rotating equipment.

This configuration features a 0.5-meter probe cable, a Miniature ClickLoc coaxial connector, and CSA, ATEX, IECEx approvals. Its PPS sensing tip and stainless steel housing support demanding industrial environments.

Technical Specifications

1. Product Identification

Manufacturer Bently Nevada
Model 330105-XX-XX-05-02-05
Modification Reference MOD 165931-01
Product Series 3300 XL 8 mm
Product Type Reverse Mount Proximity Probe
Thread Configuration 3/8-24 UNF
Total Probe Length 0.5 m (1.6 ft)
Connector Option 02 – Miniature ClickLoc coaxial connector
Approval Option 05 – CSA, ATEX, IECEx
Country of Manufacture USA

2. Electrical and Measurement Characteristics

Measurement Principle Eddy-current proximity sensing
Measurement Target Conductive rotating machinery surfaces
Nominal Probe DC Resistance 7.45 ± 0.50 Ω
Resistance Measurement Center conductor to outer conductor
Cable Impedance 75 Ω
Measurement Range Determined by the compatible calibrated measurement system
Frequency Response Depends on the connected Proximitor configuration
Sensitivity Depends on the matched probe and Proximitor system
Linearity Depends on complete system calibration
Resolution Determined by monitoring electronics and signal processing

Note: The supplied specifications do not establish numerical measurement range, sensitivity, frequency response, linearity, or resolution. Verify these parameters against the compatible Proximitor and system calibration.

3. Mechanical and Material Specifications

Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 303 or 304 stainless steel
Thread Size 3/8-24 UNF
Maximum Thread Engagement 0.563 in
Probe Weight 323 g/m (11.4 oz)
Probe-to-Lead Tensile Strength 330 N (75 lbf) maximum rated
Lead-to-Extension Connector Tensile Strength 270 N (60 lbf) maximum rated
Connector Material Gold-plated brass or gold-plated beryllium copper

4. Cable and Connector Specifications

  • Standard Cable: 75 Ω triaxial cable with FEP insulation.
  • Extended-Temperature Cable: 75 Ω triaxial cable with PFA insulation.
  • Standard Cable Lengths: 0.5, 1, 1.5, 2, 3, 5, and 9 meters.
  • Extended-Temperature Cable Lengths: 0.5, 1, 1.5, 2, 5, and 9 meters.
  • Optional Armor: Flexible AISI 302 or 304 stainless steel.
  • Armor Outer Jacket: FEP.
  • Connector Type: Miniature ClickLoc coaxial.

5. Environmental and Operating Conditions

Standard Probe Temperature -52°C to +177°C (-62°F to +350°F)
Extended-Temperature Probe Tip -52°C to +218°C (-62°F to +425°F)
Extended-Temperature Cable and Connector -51°C to +260°C (-60°F to +500°F)
Relative Humidity Performance Less than 3% average scale factor change
Humidity Test Condition 93% relative humidity
Humidity Test Duration Up to 56 days
Humidity Test Standard IEC 68-2-3
Pressure Sealing Material Viton® O-ring

Environmental Warning: Temperatures below -34°C (-30°F) may cause premature pressure-seal failure. The probe is not pressure-tested before shipment.

Core Engineering Functions

1. Shaft Displacement Monitoring

The 3300 XL 8 mm probe detects changes in the gap between its sensing tip and a conductive shaft. Compatible Proximitor electronics convert these changes into electrical signals. A monitoring system processes the signals for machinery condition analysis.

2. Reverse Mount Installation

The reverse-mount configuration accommodates specific machinery mounting arrangements. It helps engineers address restricted installation clearances. Correct positioning maintains the required probe-to-target relationship.

3. Stable Signal Transmission

The 75 Ω triaxial cable supports signal transmission between the probe and compatible electronics. Proper cable routing helps reduce unwanted electrical interference. Secure connector engagement also supports reliable signal transmission.

4. Industrial Environmental Protection

The PPS tip and stainless steel housing provide mechanical protection. Optional stainless steel armor protects the cable against physical damage. Engineers should select insulation according to actual operating temperatures.

Installation Guidelines

  1. Inspect the probe tip, housing, cable, and connector before installation.
  2. Confirm the mounting thread matches the specified 3/8-24 UNF connection.
  3. Check thread engagement against the 0.563-inch maximum.
  4. Inspect the mounting surface and conductive target condition.
  5. Install the probe according to the equipment manufacturer's instructions.
  6. Route cables away from high-voltage conductors and interference sources.
  7. Avoid excessive cable bending, tension, and sharp mechanical edges.
  8. Connect the probe to compatible extension cables and Proximitor electronics.
  9. Verify the complete measurement chain before machinery startup.

Engineering Note: Do not assume a tightening torque. Follow the applicable equipment and probe installation instructions.

Commissioning and Maintenance

Commissioning Checks

  • Verify the complete probe model and configuration.
  • Inspect Miniature ClickLoc connectors for contamination or damage.
  • Measure probe resistance when required by the maintenance procedure.
  • Confirm extension cable and Proximitor compatibility.
  • Verify system calibration and static gap voltage.
  • Compare vibration readings against established machinery baselines.

Routine Maintenance

  • Inspect cable insulation and optional armor regularly.
  • Check connectors for looseness, corrosion, and contamination.
  • Monitor signal stability during normal machinery operation.
  • Investigate unexpected changes in vibration or gap readings.
  • Replace damaged cables with compatible components.
  • Recheck system calibration after relevant component replacements.

Compatibility and Selection Guidance

The 330105-XX-XX-05-02-05 belongs to the Bently Nevada 3300 XL 8 mm proximity probe family. It requires compatible Proximitor electronics and an appropriate cable configuration.

Verify these parameters before ordering:

  • Probe family: 3300 XL 8 mm.
  • Mounting configuration: Reverse mount.
  • Thread specification: 3/8-24 UNF.
  • Probe cable length: 0.5 meter.
  • Connector configuration: Miniature ClickLoc coaxial.
  • Approval configuration: CSA, ATEX, IECEx.
  • Temperature requirements: Standard or extended-temperature configuration.
  • Extension cable and Proximitor compatibility.

Selection Advice: Do not select a replacement based only on probe diameter. Compare the complete part number, mounting arrangement, cable configuration, connector type, and calibration requirements.

Certifications and Compliance

  • CSA – Specified agency approval.
  • ATEX – Hazardous-area equipment approval.
  • IECEx – International hazardous-area certification scheme.

Confirm actual certification markings and installation requirements before using the probe in hazardous areas.

Package Contents

  • 1 × Bently Nevada 330105-XX-XX-05-02-05 Reverse Mount Proximity Probe.
  • Configured 0.5-meter probe cable.
  • Miniature ClickLoc coaxial connector.
  • Specified agency approval configuration.

The standard package does not automatically include a Proximitor sensor, extension cable, monitoring rack, or mounting accessories. Confirm additional system requirements before ordering.

Frequently Asked Questions (FAQ)

Q1: What is the primary function of the Bently Nevada 330105 probe?

The probe measures the gap between its sensing tip and a conductive target. Compatible Proximitor electronics process the signal for shaft vibration and displacement monitoring.

Q2: Can the 330105 probe connect directly to a monitoring rack?

No. The probe requires compatible Proximitor electronics and an appropriate cable configuration. The Proximitor conditions the probe signal before the monitoring system receives it.

Q3: What should engineers check when replacing an existing 3300 XL probe?

Compare the complete part numbers first. Then verify the mounting thread, probe length, connector, cable type, and system compatibility. A matching diameter alone does not guarantee interchangeability.

Q4: What causes unstable readings after probe installation?

Common causes include incorrect probe gap, loose connectors, damaged cables, and improper calibration. Electrical interference and incompatible cable combinations can also affect signal quality. Inspect the complete measurement chain before replacing the probe.

Q5: Can this probe operate continuously at 218°C?

The specified extended-temperature probe tip supports temperatures up to 218°C. However, this model description does not independently confirm an extended-temperature cable configuration. Verify the actual cable and connector ratings before installation.

Q6: Does the 330105 probe require regular calibration?

The probe operates as part of a calibrated measurement system. Verify system calibration during commissioning and after relevant component replacements. Follow the applicable machinery protection maintenance procedures.

Q7: How should engineers choose between standard and extended-temperature cable versions?

Select the cable according to actual operating temperatures near the cable and connector. Standard FEP insulation supports the standard configuration. Extended-temperature PFA insulation supports higher specified temperatures. Check the probe tip and connector temperature limits separately.

Q8: Is the probe suitable for hazardous-area installations?

This configuration specifies CSA, ATEX, and IECEx approvals. Confirm the actual certification markings, installation method, and system approval requirements before use.

Q9: What should maintenance engineers check if the probe resistance is outside specification?

Check the measurement instrument, connector condition, and cable continuity first. Compare the reading against the specified 7.45 ± 0.50 Ω value for the 0.5-meter configuration. Investigate possible conductor damage before reinstalling the probe.

Q10: How can buyers avoid selecting an incompatible replacement?

Provide the complete model number and existing system configuration. Include the thread size, cable length, connector type, and operating temperature. Technical verification helps prevent unnecessary replacement work.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.