Manufacturer: GE
Product No.: IS200TRTDH1DBB
Condition: In stock
Product Type: RTD Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview
The General Electric IS200TRTDH1DBB functions as a Simplex Resistance Temperature Detector (RTD) Input Terminal Board engineered for Mark VI and Mark VIe Speedtronic Control Systems. This board conditions signals from 16 three-wire RTD sensors across two removable 24-point barrier terminal blocks. Integrated noise suppression circuits shield temperature measurement lines from surge transients and high-frequency EMI. Dual 37-pin female connectors (JA1/JB1) link the unit directly to PRTD I/O packs or processing cards, converting analog field resistance into linearized digital temperature values for main turbine controllers.
Technical Specifications
- Manufacturer: General Electric (GE)
- Part Number: IS200TRTDH1DBB
- Product Series: Mark VI / Mark VIe Speedtronic Control
- Board Type: RTD Input Terminal Board (Simplex TRTD Variant)
- Input Capacity: 16 Channels (3-Wire RTD Configuration across 2 Terminal Blocks)
- Supported RTD Types: Platinum (10 Ω, 100 Ω, 200 Ω), Copper (10 Ω), Nickel (120 Ω)
- Excitation Current: 10 mA DC Multiplexed Output
- Voltage Span: 0.3532 V DC to 4.054 V DC
- Max Cable Resistance: 15 Ω Maximum Two-Way Lead Resistance (Up to 300 meters / 984 feet)
- Sampling Frequency: 4 Samples/sec (Normal Scan) | 25 Samples/sec (Fast Scan)
- Connector Interface: 2 x Female 37-Pin D-Shell Connectors (JA1, JB1) + 2 x DC-Type Connectors
- Hardware Configuration: Zero Jumpers or DIP Switches Required
- Noise Protection: Onboard High-Frequency Decoupling to Chassis Ground
- Country of Origin: United States (USA)
Functional Architecture
Signal Conditioning & Multiplexed Excitation
- Delivers a controlled 10 mA DC pulsed excitation current across grounded or ungrounded RTD elements.
- Filters incoming thermal signals using high-frequency RC decoupling circuits linked directly to chassis ground.
- Eliminates sensor self-heating error by multiplexing excitation pulses across active channels.
Hardware Isolation & Interface Protocols
- Routes analog millivolt drops via dual 37-pin connectors directly to paired PRTD I/O packs.
- Incorporates hardware and software limit checks to isolate out-of-range sensor channels dynamically.
- Retains electronic board identification data through an onboard ID chip for automated system discovery.
System Compatibility & Machinery Applications
The IS200TRTDH1DBB board operates within GE Mark VI and Mark VIe turbine control cabinets. Field engineers integrate this terminal module across critical rotating equipment monitoring systems:
- Heavy-duty gas turbine generator bearing metal and lube oil sumps.
- Steam turbine high-pressure casing and exhaust frame thermal monitoring.
- Combined-cycle heat recovery steam generator (HRSG) pipeline sensing.
- Large hydro-generator stator winding temperature detection assemblies.
Diagnostic Capabilities & Field Testing
- Automatic Out-of-Range Isolation: System software flags shorted or open RTD circuits instantly and removes broken channels from active scan sweeps to preserve adjacent channel accuracy.
- Self-Healing Auto-Reinstatement: Repaired or replaced temperature probes undergo automatic validation checks and rejoin active control database scans within 20 seconds.
- Real-Time Signal Trending: Transmits precise analog values to Control System Toolbox software for temperature gradient profiling and preventive maintenance tracking.
Global PLC Spare HUB's Insight
In turbomachinery control, RTD signal stability dictates trip prevention. During a scheduled outage audit on a combined-cycle plant, operators noticed erratic temperature spikes on generator bearing sensors tied to an IS200TRTDH1DBB module. Rather than a failed terminal card, physical inspection revealed loose shield drain wires on the barrier strip. High-frequency drive noise was coupling onto unshielded leads. Re-terminating double-shielded cable drain wires directly to the dedicated chassis ground strip restored pristine temperature readings. Always ensure your 3-wire RTD field cables stay within the 15-ohm two-way resistance threshold and keep shield connections tight.
Purchasing Guide
- Verify Architecture Requirements: Ensure your control loop requires a Simplex TRTD board (H1D variant) rather than a TMR fanning board (H1B variant).
- Check I/O Pack Compatibility: Confirm direct cable pin alignment with your PRTD I/O packs before mounting inside the enclosure rack.
- Inspect Field Wiring Gauge: Verify that field wiring harness connections use wire sizes up to #12 AWG to fit the 24-point removable barrier strips properly.
Package Contents & Logistics
- 1 x General Electric IS200TRTDH1DBB RTD Input Terminal Board.
- Protective ESD anti-static storage packaging.
- Standard 12-Month Comprehensive Warranty.
- Express Global Shipping: Ships worldwide within 24 to 48 hours via FedEx, UPS, or DHL.
Frequently Asked Questions (FAQ)
Q: How does the IS200TRTDH1DBB handle a sudden open-circuit fault on a bearing RTD?
A: Hardware and software limit checks detect out-of-range resistance values immediately. The board removes the faulted channel from the active scanning loop to prevent false trip signals or signal distortion on adjacent channels.
Q: What is the maximum recommended cable distance between the field RTD and this terminal board?
A: Field RTDs can be located up to 300 meters (984 feet) away from the turbine control cabinet, provided total two-way cable loop resistance remains below 15 ohms.
Q: Are jumpers required to configure different RTD curve types on the IS200TRTDH1DBB?
A: No. The board features zero jumpers or configurable hardware switches. Curve linearization for platinum, copper, or nickel RTDs is managed entirely through Control System Toolbox software.
Q: Can this terminal strip be serviced without disconnecting individual field wires?
A: Yes. Both 24-point terminal barrier blocks unplug directly from the main circuit board assembly, allowing rapid board replacement during emergency maintenance stops.
Q: What express shipping options are available for emergency machine down situations?
A: Orders process and dispatch within 24 to 48 hours via international express couriers including FedEx, UPS, and DHL.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.