IC695ALG808 GE Fanuc PACSystems RX3i 8-Ch Isolated Analog Output Module
Manufacturer: GE Fanuc
Product No.: IC695ALG808
Condition: In stock
Product Type: Analog Output Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 2000g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview
The IC695ALG808 is an 8-channel high-density isolated analog output expansion module manufactured by Emerson Automation (formerly GE Fanuc / GE Intelligent Platforms) for the PACSystems RX3i Series. Designed for precise process control, this module provides channel-to-channel and channel-to-backplane galvanic isolation. Each channel is software-configurable for current outputs (0–20 mA, 4–20 mA) or voltage outputs (0 to +10V, ±10V), enabling direct interface with modulating field actuators, control valves, variable frequency drives (VFDs), and remote data recorders.
Technical & Electrical Specifications
| Brand & Manufacturer | Emerson Automation / GE Fanuc / GE Intelligent Platforms |
| Model & Catalog Number | IC695ALG808 (PACSystems RX3i Series) |
| Module Type | 8-Channel Isolated Analog Output Module |
| Output Signal Modes | Current: 0–20 mA, 4–20 mA | Voltage: 0 to +10 VDC, ±10 VDC |
| D/A Converter Resolution | 15 bits (±10V, 0–20 mA, 4–20 mA); 14 bits (0 to 10V) |
| Analog Update Rate | 8 ms typical across all 8 output channels |
| Output Settling Time | 2 ms max (0 to 95% step response, current or voltage) |
| Calibrated Accuracy | ±0.15% of full scale at 25°C; ±0.25% of full scale at 60°C |
| Maximum Load Drive | 1350 Ohms loop impedance at 24VDC field supply |
| Isolation Withstand | 2550 VDC for 1 second (channel-to-backplane and channel-to-channel) |
| External Field Power Requirement | 19.2 to 30 VDC (24 VDC nominal); 160 mA base current (600 mA peak loop) |
| Internal Backplane Draw | 360 mA max at 3.3 VDC; 17 mA at 5.0 VDC; 7.25 W max power dissipation |
System Interconnects & Mechanical Design
| Chassis Architecture | Installs into any standard slot of the RX3i Universal Backplane (IC695) |
| Compatible Terminal Blocks | Box-Style (IC694TBB032), Ext. Box (IC694TBB132), Spring (IC694TBS032), Ext. Spring (IC694TBS132) |
| Data Representation Formats | IEEE 32-bit Floating Point or 16-bit Integer within a 32-bit field |
| Diagnostic Status Indicators | Front LED array: Module Status, Field Status, and Terminal Block Present |
| Output Protection Ratings | Overvoltage protection: -30V continuous for 60s; +30V for 1 hour on current outputs |
Target Applications & Hardware Diagnostics
The IC695ALG808 is routinely specified in oil and gas refineries, water treatment plants, and thermal processing cells where ground loop noise threatens signal integrity. Front-panel LEDs streamline fault detection: a solid Green "Module Status" confirms normal logic communication, while an Amber "Field Status" alerts engineers to missing 24VDC external power or broken field loop wiring. Software alarms (Very Low, Low, High, Very High) can be latched to trigger fault reporting in the controller CPU prior to system trips.
Global PLC Spare HUB's Insight
Channel-to-channel isolation on the IC695ALG808 eliminates the common-mode potential differences that often ruin analog drive commands in heavy industrial environments. However, field engineers frequently overlook the external power requirement: even if the backplane 3.3V power is fully functional, the analog output DAC drivers will not operate without an independent, clean 24VDC loop supply wired directly to the terminal block. Ensuring the external supply stays above 19.2 VDC under maximum load (1350 Ohms per channel) prevents unexpected output clipping.
Model Selection Comparison & Technical Recommendations
Review output density and isolation criteria within the PACSystems RX3i Series analog module family:
- Fully Isolated 8-Channel Module: The IC695ALG808 provides individual channel-to-channel isolation (2550 VDC), ideal for driving ungrounded or long-distance field actuators without cross-channel signal interference.
- Non-Isolated / Group-Isolated Options: For dense cabinets where all actuators share a common ground reference, non-isolated analog output modules offer cost efficiency but sacrifice individual ground-loop protection.
Engineering Selection Tip: When driving precision VFD speed references, set the module data format to 32-bit IEEE Floating Point in PME (PAC Machine Edition). This avoids scaling loss and allows direct engineering unit entry (e.g., 0.0 to 100.0% valve opening) directly from application logic.
Warranty, Logistics & Fulfillment Commitments
- Condition & Authenticity: 100% Original Factory Sealed product in original packaging
- Warranty Terms: Covered by a comprehensive 12 Months functional warranty
- Order Handling Speed: Dispatched within 24 to 48 hours from order confirmation
- Global Express Courier: Direct worldwide shipping via FedEx, UPS, and DHL
Frequently Asked Questions (FAQ)
Q: How do I configure an individual channel for 4–20 mA current versus ±10V voltage output?
A: Output ranges are assigned per-channel inside Proficy Machine Edition (PME) hardware configuration without setting physical hardware jumpers on the module board.
Q: What happens to the analog outputs if communication with the RX3i CPU is temporarily interrupted?
A: Channels can be programmed in software to either hold their last state or default to a predefined safety value (e.g., 0 mA or 4 mA) upon loss of CPU communications.
Q: Can I use this analog output card without connecting an external 24 VDC power supply to the terminal block?
A: No, the 3.3 VDC backplane bus only powers logic interface components; the analog output DAC stages require an external 19.2 to 30 VDC field supply.
Q: What is the maximum load resistance supported when driving a 4–20 mA current loop?
A: The module handles loop impedances up to 1350 Ohms at nominal 24VDC input power, allowing long field cable runs to remote modulating valves.
Q: How can a technician field-verify output accuracy without disconnecting the process actuator?
A: Force a known engineering value (e.g., 50% / 12 mA) via controller software and measure current inline with a calibrated digital multimeter at the removable terminal block.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.