Home Honeywell XNX-AMSI-NHNNN XNX Transmitter Optima Excel HART
Honeywell XNX-AMSI-NHNNN XNX Transmitter Optima Excel HART
Honeywell XNX-AMSI-NHNNN XNX Transmitter Optima Excel HART
Honeywell XNX-AMSI-NHNNN XNX Transmitter Optima Excel HART
Honeywell XNX-AMSI-NHNNN XNX Transmitter Optima Excel HART
Honeywell XNX-AMSI-NHNNN XNX Transmitter Optima Excel HART
Honeywell XNX-AMSI-NHNNN XNX Transmitter Optima Excel HART

Honeywell XNX-AMSI-NHNNN XNX Transmitter Optima Excel HART

  • Manufacturer: Honeywell

  • Product No.: XNX-AMSI-NHNNN

  • Condition: In stock

  • Product Type: Universal Transmitter

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 6800g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Product Overview

The Honeywell XNX Series standardizes field installation practices across multi-gas sensing architectures. The transmitter translates complex optical readings into linear, calibrated output signals for central control systems. Maintenance teams inspect status reports and calibrate field units quickly without opening the explosion-proof enclosure. This flexible transmitter architecture reduces spare parts stock requirements across complex processing facilities.

The Honeywell XNX-AMSI-NHNNN represents an advanced universal transmitter designed for demanding industrial gas detection applications. Engineers build this unit to process signals from optical infrared gas detectors like the Searchpoint Optima Plus and Searchline Excel series. The stainless steel enclosure delivers exceptional durability in harsh offshore and onshore environments. Operators receive reliable continuous monitoring, standard 4-20mA signal transmission, and flexible local HART interface accessibility.

Key Technical Specifications

  • Brand: Honeywell
  • Model Part Number: XNX-AMSI-NHNNN
  • Product Series: Honeywell XNX Universal Transmitter
  • Enclosure Material: Painted 316 Stainless Steel
  • Cable Thread Entry: 4 x M25 Metric Entries
  • Interface Personality: Infrared Searchpoint Optima / Searchline Excel compatibility
  • Analog Signal Output: 4-20mA with HART digital protocol
  • Local Communication Port: Integrated Local HART Interface
  • Operating Temperature Range: -40°C to +65°C (-40°F to +149°F)
  • Storage Temperature Range: -40°C to +65°C (-40°F to +149°F)
  • Operating Pressure Limits: 80 kPa to 120 kPa
  • Operating Humidity Limits: 0% to 99% RH non-condensing
  • Air Velocity Limits: 0 to 6 meters per second
  • Ingress Protection Rating: IP66 Enclosure Protection
  • Explosion Protection Approvals: ATEX and IECEx Zone Certified
  • Unit Physical Weight: 6.8 Kg
  • Output Relays Option: None installed (Standard Base Unit)

Technical Performance Matrix

Performance Parameter Engineering Specification Detail
Measurement Range Target sensor dependent (0-100% LEL or LEL-m)
Signal Sensitivity High-resolution detection tailored to optical sensors
Signal Linearity Linear 4-20mA output over full scale range
System Resolution 0.1% LEL digital communication output resolution
Frequency Response Rapid dynamic step response under T90 limits
Noise Immunity Industrial EMC compliant shielding design
Environmental Endurance Vibration, salt spray, and weather resistant IP66

Installation Guidance

  • Mount the enclosure securely onto rigid structural steel supports or solid concrete walls.
  • Use certified M25 cable glands to maintain the strict IP66 ingress protection rating.
  • Seal all unused cable entry ports using approved metal stopping plugs before applying power.
  • Connect the main ground conductor directly to the external enclosure grounding stud terminal.
  • Verify supply power voltage remains within specified terminal limits prior to final powerup.

Commissioning and Maintenance Convenience

Field technicians configure parameters easily through the magnetic user interface using an external handheld tool. The local HART interface port allows point connection without compromising the explosion-proof boundary. Routine calibration procedures require minimal setup time because the software guides operators step by step through span gas adjustments.

System Compatibility

  • Direct integration with Searchpoint Optima Plus hydrocarbon gas detectors.
  • Seamless operation with Searchline Excel open-path infrared gas monitoring systems.
  • Compatible with generic 4-20mA loops in standard Distributed Control Systems (DCS).
  • Interfaces smoothly with modern Programmable Logic Controllers (PLCs) supporting HART protocols.

Certifications and Regulatory Compliance

The unit carries full ATEX and IECEx international certifications for hazardous location deployments. The rugged 316 stainless steel housing meets tough marine standards for offshore platforms and coastal processing plants.

Typical Application Scenarios

  • Offshore oil drilling platforms and floating production storage vessels (FPSO).
  • Onshore petroleum refineries, tank farms, and fuel distribution terminals.
  • Chemical processing plants requiring continuous combustible hydrocarbon gas monitoring.
  • Liquefied Natural Gas (LNG) processing facilities and export marine terminals.

Diagnostic and Self-Monitoring Capabilities

The internal circuitry continually evaluates hardware health, optical alignment stability, and signal integrity. When the device detects faults or dirty optical paths, it updates HART diagnostic codes instantly. This predictive alert feature helps instrument engineers execute targeted maintenance before unexpected trip outages occur.

Global PLC Spare HUB's Insight

In real-world offshore installations, instrument technicians frequently face challenges with moisture ingress causing false ground fault alarms. When commissioning the Honeywell XNX-AMSI-NHNNN, applying approved thread sealant on the M25 glands prevents salt air moisture penetration. During a recent maintenance audit on an FPSO platform, converting legacy standard 4-20mA transmitters to this HART-enabled Honeywell XNX platform reduced optical calibration times by 40% because field engineers performed remote zero checks without opening junction boxes.

Package Contents and Warranty Details

  • 1 x Honeywell XNX-AMSI-NHNNN Universal Gas Transmitter Assembly
  • 1 x Quick Start Reference Guide and Wiring Diagram Manual
  • Standard 12-Month Factory-Backed Warranty covering manufacturing defects

Global Logistics and Fast Shipping

Orders ship worldwide within 24 to 48 hours after payment confirmation. Reliable delivery service is provided via tier-one express courier networks including FedEx, UPS, and DHL.

Selection and Purchasing Guide

  • Verify target gas sensor types match the "I" personality interface option built into this model.
  • Confirm enclosure cable entry thread size requirements (M25 thread standard for this configuration).
  • Ensure the control system analog input channel supports passive 4-20mA loop signals with HART decoding.

Frequently Asked Questions (FAQ)

What does the personality code "I" specify on this model?

The "I" code indicates the transmitter features an interface personality designed specifically for infrared products like Searchpoint Optima and Searchline Excel.

Can I install optional relay or Modbus boards later?

Yes, technicians can install internal option boards into the base unit, though relay, Modbus, and Fieldbus options are mutually exclusive within the housing.

How do I connect a HART communicator in hazardous areas?

Connect your intrinsically safe HART communicator directly to the external local HART interface port on the bottom of the enclosure.

What cable size should I use for field wiring?

Use shielded twisted-pair cabling with conductor sizes ranging between 0.5 mm² (20 AWG) and 2.5 mm² (14 AWG) to ensure signal integrity.

How does this unit handle temperature extremes on marine decks?

The heavy-duty 316 stainless steel casing operates safely down to -40°C and up to +65°C without requiring additional thermal insulation jackets.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.