ABB PFEA111-20 Tension Electronics – Dual-Channel Measurement and Signal Processing

The ABB PFEA111-20 is tension electronics designed for industrial web tension measurement systems. It processes signals from two load cells and provides voltage and current outputs for downstream control equipment.

The unit supports separate channel readings and calculated values. Operators can view A, B, A+B, and A-B on the display. This allows the control system to monitor individual load cell signals and combined tension values.

Adjustable output filtering helps reduce signal fluctuations caused by mechanical vibration or process disturbances. The voltage and current outputs can be configured for different tension ranges and response requirements.

01 | Measurement Architecture

The PFEA111-20 operates as a signal-processing interface between load cells and the plant control system.

Signal processing path:

  • Input A: Receives the signal from the first load cell.
  • Input B: Receives the signal from the second load cell.
  • Signal calculation: Provides A, B, A+B, and A-B display values.
  • Output stage: Delivers voltage and current signals to external control equipment.
  • Filtering: Provides adjustable filtering for both analog output channels.

This arrangement is useful when two load cells monitor tension across a roll or web-handling process. The separate readings also help technicians identify differences between the two measurement points.

02 | Electrical and Measurement Specifications

Parameter Specification
Product model PFEA111-20
ABB Product ID 3BSE050090R20
Product type Tension Electronics
Number of load cell inputs 2
Input impedance 10 kΩ
Load cell excitation 0.5 A RMS, 330 Hz, regulated
Display values A, B, A+B, A-B
Voltage output 0–10 V
Voltage output range -5 to +11 V
Maximum voltage output load 5 mA
Voltage output ripple <10 mV p-p at wrap gain = 1
Current output 4–20 mA
Current output range 0–21 mA
Maximum current output load 550 Ω
Default output response time 15 ms
Standard output bandwidth 35 Hz
Wrap gain adjustment 0.5–20

03 | Adjustable Filtering and Dynamic Response

The PFEA111-20 provides additional filtering for voltage and current outputs. The filter setting affects how quickly the output follows changes in measured tension.

Filter Setting Cut-off Frequency
30 ms 15 Hz
75 ms 5 Hz
250 ms 1.5 Hz
750 ms 0.5 Hz
1500 ms 0.25 Hz

Practical commissioning considerations:

  • Use a faster filter when the process requires rapid tension response.
  • Use a slower filter when mechanical vibration causes unstable analog readings.
  • Check the response at both outputs after changing the filter setting.
  • Verify that the selected filter does not delay important tension corrections.

A longer filtering time can stabilize the displayed and transmitted values. However, excessive filtering may delay the control system's response to sudden tension changes.

04 | Load Cell Excitation and Measurement Range

The electronics provide regulated excitation for two compatible load cells. The specified maximum load includes two load cells, cable resistance up to 5 Ω, and cable capacitance up to 1 μF.

Compatible load cell types listed in the technical information:

  • PFCL 301E
  • PFTL 301E
  • PFRL 101
  • PFTL 101
  • PFCL 201
  • PFTL 201

Measurement range reference:

Measurement Parameter Range
Zero setting range ±2.0 × F_nom
Dynamic measurement range, including zero setting -2.5 × F_nom to +3.5 × F_nom

F_nom represents the nominal load of the connected load cell. The actual measurement range depends on the selected load cell rating and system configuration.

05 | Power Supply and Installation Versions

The supplied technical information describes two enclosure configurations. Their power requirements and protection ratings differ.

Parameter IP20 Version IP65 Version
Mounting DIN rail Wall mounting
Protection rating IP20 IP65
24 V DC supply 18–36 V DC 18–36 V DC
AC supply Not specified 85–264 V AC
Fuse protection Automatic reset Slow-blow, 2 A, 250 V
Dimensions (W × H × D) 86 × 136 × 58 mm 120 × 180 × 100 mm
Listed version weight 0.3 kg 1.9 kg

For the AC supply version, the specified mains frequency is 45–65 Hz. The listed input current is 0.2–0.1 A across the 100–240 V AC range.

The stated power consumption is 8 W at 24 V DC.

Installation note: Confirm the enclosure version before selecting the power supply, mounting location, and cabinet cut-out. Do not assume that every PFEA111-20 order uses the same enclosure configuration.

06 | Configuration Parameters and Output Scaling

The supplied PFEA111 default configuration provides a useful reference for commissioning. Actual settings must match the installed load cells and mechanical arrangement.

Setting Default Value
Display language English
Display unit N
Decimal places 0
Load cells per roll 2
Object type Standard roll
Load cell nominal load 1.0 kN / 225 lbs
Wrap gain 1
Current output filter 250 ms
Current output low tension 0 N
Current output high tension 2000 N
Current output low value 4.00 mA
Current output high value 20.00 mA
Current output limits 0–21 mA
Voltage output filter 250 ms
Voltage output low tension 0 N
Voltage output high tension 2000 N
Voltage output low value 0.00 V
Voltage output high value +10.00 V
Voltage output limits -5 to +11 V

When integrating the unit with a PLC or DCS, verify the configured tension span and output scaling at both ends of the measurement range. A mismatch between the electronics and controller scaling can produce incorrect engineering values even when the analog signal is electrically stable.

07 | Environmental and Mechanical Data

Parameter Specification
Operating temperature +5 to +55 °C
Storage / non-operating temperature -40 to +70 °C
Zero point temperature drift <50 ppm/K
Sensitivity temperature drift <75 ppm/K
IP20 version protection IP20
IP65 version protection IP65, NEMA 4

The operating temperature specification applies to the outside of the IP20 and IP65 units. Check the actual cabinet environment and ventilation conditions before installation.

08 | Field Commissioning Checks

  1. Verify the hardware version. Confirm the product identification, enclosure type, and supply voltage before wiring.
  2. Check load cell compatibility. Confirm the sensor model, nominal load, excitation requirements, and cable characteristics.
  3. Inspect both input channels. Compare A and B readings under a known mechanical load. Investigate unexpected differences before calibrating.
  4. Confirm output scaling. Check the configured low and high tension values against the PLC or DCS engineering range.
  5. Test filtering behavior. Apply a controlled tension change and observe the output response. Select a filter setting that balances stability and response time.
  6. Verify zero and span. Perform zero adjustment and calibration using the approved procedure for the installed system.

For an unstable tension reading, compare the individual A and B values before changing the filter. If both channels fluctuate together, inspect mechanical vibration, excitation, grounding, and cable routing. If only one channel fluctuates, investigate its load cell and wiring first.

09 | Product Identification and Ordering Details

Item Information
Brand ABB
Model PFEA111-20
Product ID 3BSE050090R20
Product family PFEA111
Product description Tension Electronics
Country of origin Sweden
Customs tariff number 85389091
Minimum order quantity 1 piece
Order multiple 1 piece
Listed gross weight 0.2 kg
Listed net weight 0.2 kg
Previous product ID 3BSE028140R20

Ordering note: The listed 0.2 kg weight is the commercial product record value. It should not be confused with the separately specified IP20 and IP65 enclosure weights.

10 | Professional FAQ

Q1: What should technicians check if the A and B readings differ significantly under the same mechanical condition?

First, check load cell mounting, roller alignment, cable connections, and mechanical load distribution. Then compare the two channels under a controlled load. Do not correct the difference through output scaling before confirming the mechanical installation.

Q2: Can the PFEA111-20 directly replace another PFEA111 unit without recalibration?

Not automatically. Confirm the complete product ID, hardware version, enclosure, load cell rating, and stored configuration. Even when the replacement has matching hardware, verify zero, span, output scaling, and filter settings during commissioning.

Q3: Why might the PLC display a different tension value from the PFEA111-20 front panel?

Common causes include different engineering ranges, incorrect analog input scaling, signal wiring errors, and mismatched output assignments. Measure the actual voltage or current at the controller input. Compare that value with the PFEA111-20 output configuration before changing calibration settings.

Q4: What is the practical difference between using A+B and A-B during troubleshooting?

A+B represents the combined channel reading, while A-B shows the difference between the two channels. The combined value helps assess overall tension. The difference value can help identify uneven loading, sensor imbalance, or mechanical alignment problems. Interpret both values according to the configured measurement arrangement.

Q5: What information should be checked before ordering a replacement for an installed unit?

Record the complete ABB product ID, enclosure protection rating, supply voltage, terminal arrangement, load cell models, and application settings. Also confirm whether the existing system uses separate analog outputs for voltage and current. These checks reduce the risk of ordering a unit with an incompatible installation configuration.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.