Home EVF9330-EV Lenze 9300 Series High Power Frequency Inverter

EVF9330-EV Lenze 9300 Series High Power Frequency Inverter

  • Manufacturer: Lenze

  • Product No.: EVF9330-EV

  • Condition: In stock

  • Product Type: Frequency Inverter

  • Product Origin: DE

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

LENZE 9300 VECTOR DRIVE | PRODUCT PROFILE

Lenze EVF9330-EV is a high-power frequency inverter from the 9300 Series. It controls three-phase AC motors in demanding industrial drive applications.

The drive supports a typical 55 kW (74 HP) four-pole asynchronous motor. Its power architecture supports three-phase AC input and an alternative DC supply.

The controller provides different output power ratings according to its switching frequency. Engineers can select the appropriate operating configuration based on motor load and thermal requirements.

Its control-cabinet back-panel mounting arrangement supports centralized drive installation. The 9300 vector platform suits applications requiring controlled motor speed and torque.

01 | PRODUCT IDENTIFICATION & CONFIGURATION

Identification Details
Manufacturer Lenze
Product Model EVF9330-EV
Product Family 9300 Series
Drive Platform 9300 Vector
Product Category Frequency Inverter / AC Drive Controller
Motor Type Three-phase asynchronous motor
Typical Motor Rating 55 kW / 74 HP
Installation Control cabinet back-panel mounting

Ordering code reference:

  • EVF – Lenze 9300 vector drive product designation.
  • 9330 – 9300 drive model and power class.
  • -EV – Ordering suffix appearing in the supplied product reference.

Configuration note: The above breakdown identifies the product family and ordering reference. It does not assign undocumented electrical meanings to individual suffix characters.

02 | ELECTRICAL POWER ARCHITECTURE

Electrical Parameter Rated Specification
AC Input Voltage 320–440 V AC
AC Input Configuration Three-phase, 3/PE
Mains Frequency 45–65 Hz
Alternative DC Supply 460–620 V DC
Mains Current 97 A with specified mains choke/filter operating configuration
Typical Motor Power 55 kW / 74 HP
Output Power at 2/4 kHz 74.8 kVA
Output Power at 8 kHz 61.7 kVA
Power Loss 1350 W, according to supplied product data
Operating Temperature 0 °C to +40 °C

03 | SWITCHING FREQUENCY & LOAD CAPABILITY

The switching frequency affects inverter output capacity and thermal loading. The specified output ratings provide two operating reference points.

Switching Frequency Output Apparent Power Engineering Consideration
2 kHz 74.8 kVA Lower switching frequency operating condition.
4 kHz 74.8 kVA Specified output rating for this frequency range.
8 kHz 61.7 kVA Reduced output capacity requires load verification.

Application consideration: Higher switching frequency can improve motor current waveform quality. However, it also increases switching losses and thermal stress.

Do not select the drive using motor horsepower alone. Compare motor rated current with the inverter's permissible continuous output current.

04 | CONTROL CABINET INSTALLATION

The EVF9330-EV uses back-panel mounting inside an electrical control cabinet. Correct installation helps maintain thermal stability and electrical reliability.

  • Mounting position: Install the inverter on a rigid vertical cabinet backplate, following the manufacturer's mounting instructions.
  • Cooling clearance: Maintain the specified ventilation space around the heatsink and air passages.
  • Thermal design: Account for approximately 1350 W power loss when evaluating cabinet cooling, subject to confirmation of the applicable rating.
  • Input protection: Select upstream fuses and protective devices according to Lenze specifications.
  • Mains choke/filter: Use the prescribed mains components for the applicable EVF9330 operating configuration.
  • Cable routing: Separate motor cables from sensitive signal and feedback wiring.
  • Grounding: Establish reliable protective earth connections.
  • DC supply: Verify DC voltage polarity and permissible voltage before connecting the DC bus.

Never connect AC mains and the alternative DC supply simultaneously. Follow the approved supply arrangement and wiring diagrams.

05 | COMMISSIONING & DRIVE PARAMETER CHECKS

Commissioning should begin with electrical inspection and motor nameplate verification.

  1. Confirm the inverter model and rated supply voltage.
  2. Check the mains choke and filter arrangement.
  3. Inspect input terminals, protective earth and motor connections.
  4. Enter the motor rated voltage, current and frequency.
  5. Configure the motor control parameters according to the application.
  6. Set the switching frequency within the permitted operating range.
  7. Check acceleration and deceleration times.
  8. Verify motor rotation direction at low speed.
  9. Monitor output current during initial loading.
  10. Check heatsink temperature and cabinet ventilation.

Record the original parameter configuration before modifying an existing drive. This helps engineers restore the previous operating conditions during troubleshooting.

06 | INDUSTRIAL APPLICATIONS

The 9300 vector drive provides motor control for industrial equipment requiring substantial drive capacity.

  • Industrial pumps and high-capacity pumping systems.
  • Ventilation and industrial fan equipment.
  • Conveyor systems and material handling machinery.
  • Production line drive assemblies.
  • Industrial mixers and process machinery.
  • Mechanical transmission and motor-driven equipment.
  • General-purpose industrial AC motor control.

Final suitability depends on motor current, load characteristics, overload requirements and operating duty cycle.

07 | TROUBLESHOOTING & MAINTENANCE

Observed Condition Recommended Inspection
DC bus voltage abnormal Check supply voltage, rectifier circuit and DC bus connections.
Drive overheating Inspect cooling airflow, cabinet temperature and switching frequency.
Motor current excessive Check motor parameters, mechanical load and acceleration settings.
Unexpected motor trip Review the fault history and verify motor and inverter operating limits.
Unstable motor operation Check control parameters, motor connections and feedback signals where applicable.

Clean ventilation passages during scheduled maintenance. Inspect electrical terminals for looseness and overheating.

Always isolate the power supply before servicing. Allow the DC bus capacitors to discharge according to the manufacturer's safety procedure. Verify the DC bus voltage before touching internal components.

08 | ENGINEERING SELECTION CHECKLIST

Before selecting the EVF9330-EV, engineers should verify the following conditions:

  • Three-phase AC supply within the specified voltage and frequency range.
  • Alternative DC supply requirements, if applicable.
  • Motor rated current and rated power.
  • Required switching frequency.
  • Continuous and short-time overload requirements.
  • Cabinet cooling capacity and installation clearances.
  • Mains choke and mains filter specifications.
  • Motor cable length and EMC requirements.
  • Existing control system and drive interface compatibility.

Important: A 74 HP motor rating does not guarantee suitability for every 55 kW application. Check the actual motor current and load duty before replacement.

09 | WARRANTY & PRODUCT ASSURANCE

  • Product identification: Model and manufacturer verification before dispatch.
  • Inspection: External condition and order specification checks.
  • Warranty: 12-month warranty under the agreed sales terms.
  • Technical support: Assistance with model identification and replacement compatibility.
  • Quality issues: Contact our team for inspection and warranty assessment.

The 12-month warranty covers verified product quality defects under normal operating conditions. Incorrect installation, electrical misuse and external damage are excluded.

10 | PACKING & GLOBAL DELIVERY

We arrange protective packaging for industrial automation equipment. The final packing list follows the confirmed order.

  • 1 × Lenze EVF9330-EV frequency inverter.
  • Product identification and applicable documentation, subject to supply scope.

Available international shipping services:

  • FedEx International Express.
  • UPS Worldwide Shipping.
  • DHL Express.

Shipping arrangements depend on destination, shipment dimensions and carrier availability. Contact our team for delivery options and freight quotations.

11 | FREQUENTLY ASKED QUESTIONS

Q1: Why does the inverter require a mains choke or mains filter?

The prescribed input components help meet the drive's electrical operating requirements. They also support the specified input current and power supply arrangement. Check the Lenze wiring documentation before selecting replacement components.

Q2: What should engineers consider when increasing the switching frequency from 4 kHz to 8 kHz?

The inverter's specified output capacity decreases at 8 kHz. Engineers should recalculate the motor current margin and thermal loading. Do not retain the lower-frequency load rating without checking the applicable derating data.

Q3: Can the EVF9330-EV operate from a common DC bus?

The drive supports an alternative DC supply within its specified voltage range. However, the DC bus arrangement must meet Lenze requirements. Verify supply protection, pre-charging and energy management before integration.

Q4: What information is necessary when replacing an existing 9300 drive?

Record the complete model number, motor nameplate data and existing parameter settings. Also inspect the mains choke, filter, cabinet dimensions and motor cable arrangement. Confirm the replacement's electrical ratings before installation.

Q5: How should buyers choose between EVF9330-EV and a higher-rated 9300 drive?

Compare continuous output current, overload duration and motor load characteristics. Consider the required switching frequency and cabinet cooling capacity. Select the higher-rated model when the actual operating duty exceeds the EVF9330-EV limits.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.