Lenze EVS9328-ES Global Drive 9300 Servo Inverter
The Lenze EVS9328-ES is a 22 kW servo inverter from the Global Drive 9300 series. It is designed for controlled operation of three-phase asynchronous motors in industrial motion and automation systems.
This drive uses vector control and supports resolver, incremental TTL encoder, and SinCos encoder feedback through its dedicated interfaces. It integrates analog and digital I/O, CAN system bus communication, an AIF automation interface, and expansion options for additional fieldbus protocols.
The EVS9328-ES provides rated output current of 47.0 A at 8 kHz and 30.6 A at 16 kHz. Its maximum output current is 150% of rated current, subject to the specified operating conditions and switching frequency.
01 | Drive Identification & Performance Profile
| Identification Item | Technical Information |
|---|---|
| Manufacturer | Lenze |
| Model | EVS9328-ES |
| Product Series | Global Drive 9300 |
| Product Type | Servo Inverter |
| Rated Motor Power | 22.0 kW, 4-pole asynchronous motor, servo rating |
| Output Power | 32.6 kVA |
| Control Architecture | Vector control |
| Motor Voltage | Three-phase, 0 to Vmains |
| Weight | Approximately 12.5 kg |
Product identification: EVS9328-ES is the specified Lenze order code for the 22 kW power class. Confirm the complete nameplate code when replacing an existing drive.
02 | Output Ratings: Switching Frequency Matters
The available output current depends on the selected switching frequency. Engineers should use the corresponding current rating when sizing the motor and evaluating drive loading.
| Output Parameter | 8 kHz | 16 kHz |
|---|---|---|
| Rated Output Current | 47.0 A | 30.6 A |
| Maximum Output Current | 70.5 A | 45.9 A |
| Maximum Current Ratio | 150% × In | 150% × In |
Additional electrical ratings:
- Rated motor power: 22.0 kW.
- Output apparent power: 32.6 kVA.
- Mains current at 400 V: 44.0 A.
- Motor output voltage: 0 to Vmains, three-phase.
- Maximum output current: 150% of rated current.
The maximum output current figures are based on the published 150% × In ratings. An overload specification of 180% for 60 seconds is not adopted because it is not confirmed in the cited official product data.
03 | Supply Requirements and Power Loss
| Electrical Parameter | Specification |
|---|---|
| Supply Voltage | 320–528 V AC |
| Supply Frequency | 45–65 Hz |
| Mains Current at 400 V | 44.0 A |
| Power Loss at 400 V | 640 W |
| Power Derating Above 40°C | 2.5% per °C |
| Altitude Derating | 5% per 1,000 m from 1,000 to 4,000 m |
Panel design considerations:
- Size the upstream supply and protection devices according to the drive's electrical ratings and the applicable installation manual.
- Account for approximately 640 W of drive power loss when calculating cabinet heat dissipation.
- Provide sufficient ventilation and clearance around the inverter.
- Apply current derating when the ambient temperature exceeds 40°C.
- Include altitude-related derating for installations above 1,000 m.
04 | Motor Feedback and Control Interfaces
The 9300 servo platform supports several motor feedback technologies. The selected feedback device must match the motor, encoder interface, and configured control strategy.
| Interface | Function | Connection Details |
|---|---|---|
| X7 | Motor feedback | Resolver input and KTY motor temperature sensor |
| X8 | Encoder feedback | TTL incremental encoder or Stegmann SinCos encoder; KTY temperature sensor support |
| X1 | Automation interface | AIF interface |
| X3 | Analog input configuration | Jumper for analog input signal selection at X6/1 and X6/2 |
| X4 | System communication | CAN system bus |
| X5 | Digital I/O | Digital inputs and outputs |
| X6 | Analog I/O | Analog inputs and outputs |
| X9 | Frequency input | Digital frequency input |
| X10 | Frequency output | Digital frequency output |
| X11 | Safe standstill relay | K_SR relay output on V004/V104 variants only |
Specified analog interface signals:
- AIN1: X6.1 / X6.2.
- AOUT1: X6.62.
- AOUT2: X6.63.
The X11 K_SR relay output is variant-dependent. Do not assume this function is available on every EVS9328-ES hardware version. Verify the complete variant designation before using it in a safety-related design.
05 | Communication and Automation Integration
The Global Drive 9300 platform combines built-in communication interfaces with optional plug-in expansion modules.
| Communication Interface | Supported Function |
|---|---|
| RS232 / RS485 | Serial communication through Global Drive Control |
| CAN System Bus | Integrated system bus communication |
| AIF | Automation interface and expansion connection |
| INTERBUS-S | Fieldbus communication through a plug-in module |
| PROFIBUS | Fieldbus communication through a plug-in module |
| LECOM A/B | Serial communication using RS232/RS485 through the applicable interface configuration |
Communication capability depends on the installed expansion hardware and configuration. Confirm the required protocol module before integrating the drive into an existing PLC or DCS network.
06 | Braking System: External Hardware Required
The EVS9328-ES requires an external braking solution for applications that need controlled dissipation of regenerative energy. The published 9300 product information identifies the following brake components.
| Brake Component | Technical Specification | Application |
|---|---|---|
| 9351 Brake Module | Integrated 47 Ω brake resistor; maximum peak braking power 12 kW; 1% duty cycle per 4 seconds | External braking solution with integrated resistor |
| 9352 Brake Chopper | Minimum external braking resistance 18 Ω | External braking solution using a separately selected resistor |
Brake selection checks:
- Calculate the regenerative energy generated during deceleration.
- Check the required braking power and duty cycle.
- Verify the resistor value against the brake chopper requirements.
- Check thermal limits and resistor installation conditions.
- Follow the Lenze brake module and brake chopper installation instructions.
Do not treat the 9351 and 9352 as interchangeable resistor assemblies. Their braking hardware arrangements and external resistor requirements differ.
07 | Environmental Limits and Mechanical Installation
| Parameter | Specification |
|---|---|
| Operating Temperature | 0 to +50°C |
| Rated Output Above 40°C | Reduce output current by 2.5% per °C |
| Storage Temperature | -25 to +60°C |
| Relative Humidity | Average 85% RH, no condensation |
| Climatic Classification | 3K3 |
| Protection Rating | IP20 |
| Pollution Degree | 2 |
| Dimensions (H × W × D) | 350 × 250 × 250 mm |
| Weight | Approximately 12.5 kg |
Mechanical installation notes:
- The dimensions are family-aggregated values for the 9327, 9328, and 9329 models.
- The stated dimensions exclude additional depth from the terminal shield and front keypad attachment.
- IP20 protection requires installation inside a suitable electrical cabinet.
- Maintain adequate airflow and cabinet ventilation to manage drive heat losses.
- Prevent moisture condensation during operation and storage.
08 | Compliance and Electrical Safety
| Compliance Area | Reference |
|---|---|
| CE Conformity | Low-Voltage Directive 2006/95/EC |
| Electrical Safety | EN 61800-5-1 |
| EMC Category | C2 according to EN 61800-3, typical drive configuration |
| UL / UR | UL/UR safety and branch-circuit protection requirements documented in the applicable manual |
| Short-Circuit Rating | 5,000 / 50,000 A RMS symmetrical, 480 V maximum, depending on the specified fuse arrangement |
For UL/UR installations, use the specified J, T, or R class fuses and follow the applicable branch-circuit protection instructions. Confirm the required short-circuit current rating and protection arrangement for the actual installation.
09 | Commissioning and Drive Replacement Checklist
- Verify the drive rating: Match the EVS9328-ES power class and motor current requirements.
- Check the motor feedback: Identify whether the motor uses a resolver, TTL incremental encoder, or SinCos encoder.
- Review parameter compatibility: Back up existing drive parameters and record motor data before replacement.
- Confirm communication hardware: Check CAN, AIF, and any installed fieldbus expansion modules.
- Inspect braking equipment: Verify whether a 9351 brake module or 9352 brake chopper is required.
- Calculate cabinet cooling: Include the specified drive power loss and the actual operating environment.
- Check safety-related functions: Confirm the hardware variant and applicable safety documentation before using any safe standstill-related interface.
- Perform controlled startup: Verify rotation direction, feedback operation, acceleration, deceleration, and current loading.
Always isolate the power supply and follow the approved electrical safety procedure before installation or maintenance. Use the applicable Lenze manual for parameterization, wiring, and commissioning.
10 | Product Lifecycle and Replacement Planning
The Lenze Global Drive 9300 servo inverter belongs to a previous-generation product range. Lenze documents the i950 servo inverter as a migration path for 9300 applications.
The documented migration approach includes compatibility-related functions and engineering resources such as:
- i950 compatibility switch for supported 9300 behavior.
- Applicable i950 PROFIBUS communication module.
- L_ICIP library for supported migration and integration tasks.
A migration should not be treated as a direct hardware substitution. Engineers must review motor feedback, control behavior, fieldbus configuration, parameter mapping, safety functions, braking hardware, and cabinet wiring before selecting a replacement platform.
11 | Supply, Warranty and Shipping
| Commercial Information | Details |
|---|---|
| Manufacturer | Lenze |
| Model | EVS9328-ES |
| Product Series | Global Drive 9300 |
| Product Type | 22 kW Servo Inverter |
| Condition | New & Original in Factory Packing |
| Warranty | Factory Warranty: 12 Months |
| Shipping | FedEx, UPS, DHL |
Contact Global PLC Spare HUB for EVS9328-ES pricing, availability, and delivery information. For replacement projects, provide the motor nameplate, feedback type, communication requirements, and existing brake configuration to support a more accurate compatibility review.
12 | Engineering FAQs
Q1: Can I replace an EVS9328-ES with another 22 kW inverter based only on motor power?
No. Motor power alone is not sufficient for drive selection. Compare rated and peak output current, switching frequency, motor feedback, supply voltage, control mode, communication interfaces, and braking requirements. A replacement must also support the machine's acceleration, deceleration, and dynamic load profile.
Q2: Why does the available output current decrease when the switching frequency changes from 8 kHz to 16 kHz?
Higher switching frequency increases switching-related losses in the power stage. The drive therefore has a lower published continuous output current at 16 kHz. When configuring the application, use the current rating for the selected switching frequency rather than assuming the 8 kHz rating remains available.
Q3: What information should I collect before transferring parameters to a replacement drive?
Record the motor nameplate data, feedback device type, encoder resolution where applicable, control mode, speed and torque limits, acceleration and deceleration ramps, I/O assignments, and fieldbus settings. Also document brake control and machine interlocks. Parameter transfer should be followed by a controlled functional test.
Q4: How can I determine whether the existing braking hardware is suitable for a machine with frequent stopping cycles?
Estimate the regenerative energy per stop, stopping frequency, motor inertia, and required deceleration time. Compare the calculated braking duty with the 9351 module's specified peak power and duty cycle, or the 9352 chopper's resistor requirements. Frequent stopping may require a different braking design from an occasional emergency or normal deceleration cycle.
Q5: What should I investigate if a drive operates normally when cold but trips after the cabinet warms up?
Check cabinet temperature, ventilation, fan operation, surrounding heat sources, and actual motor current. Above 40°C, the specified output current must be derated by 2.5% per °C. Also inspect electrical connections and the drive's fault history. Do not increase current limits to compensate for inadequate cooling.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.