146054-08-50-00-00 Bently Nevada Ceramic Proximity Probe
Manufacturer: Bently Nevada
Product No.: 146054-08-50-00-00
Condition: In stock
Product Type: Vibration Sensor
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Bently Nevada 146054-08-50-00-00 3300 Ceramic Capped Proximity Probe Architecture Overview
Instrumentation engineers implement the 146054-08-50-00-00 ceramic-capped proximity probe within extreme industrial measurement environments. This factory-original assembly utilizes an alumina ceramic tip to withstand abrasive media and high-temperature conditions. Bently Nevada designs this 3300 Series transducer for precise vibration and position monitoring in aggressive machinery.
Configuration Breakdown and Suffix Hierarchy
| Parameter Designation | Configured Suffix Option | Engineering Specification |
|---|---|---|
| Manufacturer Brand | Bently Nevada | Original Equipment Manufacturer |
| Base Product Family | 146054 | 3300 Ceramic Capped Probe Platform (3/8-24 UNF thread, without armor) |
| Complete Part Number | 146054-08-50-00-00 | Fully assembled probe including case length, total length, connector, and approval options |
| Overall Case Length Option | -08 | 0.8 inches physical case length |
| Total Length Option | -50 | 5.0 meters (16.4 feet) total electrical length (for use with 5 m Proximitor sensors only) |
| Connector and Cable-Type Option | 00 | No connector attached to the probe lead termination |
| Agency Approval Option | -00 | Not required hazardous location certification |
Electrical and Mechanical Performance Specifications
- Linear Measurement Range: 1.52 mm (60 mils) spanning from 0.25 to 1.78 mm (10 to 70 mils) (-4 to -16 Vdc)
- Incremental Scale Factor (ISF): 7.87 V/mm (200 mV/mil) nominal output for standard 5-metre systems
- Nominal DC Resistance: 8.73 ± 0.70 ohms measured from center conductor to outer conductor
- Maximum Thread Engagement Length: 0.563 inches with 3/8-24 UNF probe case thread
- Pressure Sealing Rating: Rated to seal 34 Bar (500 psi) nitrogen pressure environments
- Operating and Storage Temperature: -51°C to +177°C (-60°F to +351°F) probe thermal limits
Explosive Atmosphere Temperature Classifications
- For EPL Ga and Gc (Ambient Probe Range): T1 class covers -55°C to +232°C; T2 covers -55°C to +177°C; T3 covers -55°C to +120°C; T4 covers -55°C to +80°C; T5 covers -55°C to +40°C
- For EPL Dc (Dust Ratings): T280°C at Ta -55°C to +232°C; T225°C at Ta -55°C to +177°C; T170°C at Ta -55°C to +120°C; T130°C at Ta -55°C to +80°C; T105°C at Ta -55°C to +100°C; T90°C at Ta -55°C to +40°C
Logistics and Warranty Terms
We supply 100% brand new, factory-original units housed in secure packaging. Orders dispatch within 24 to 48 hours via premium global courier networks including FedEx, UPS, and DHL. Every purchase includes a comprehensive 12-month factory warranty.
Target Machinery, Application Scenarios, and Diagnostics
Plant operators deploy the 146054-08-50-00-00 ceramic-capped probe in high-temperature slurry pumps, slag grinders, and heavy chemical reactors where standard polymer probe tips experience chemical erosion or thermal degradation. The alumina ceramic tip resists aggressive chemical attack while tracking shaft vibration. Monitoring systems process these high-resolution voltage fluctuations to detect mechanical unbalance, fluid cavitation, and bearing wear under severe industrial conditions.
Global PLC Spare HUB Insight & Field Engineering Experience
Instrumentation engineers frequently observe signal degradation when 5-metre probes are mistakenly paired with standard 1-metre proximitor sensors due to mismatched capacitance tuning. For instance, a minerals processing plant resolved erratic vibration readings on a high-temperature slurry agitator by verifying that the 5-metre probe matched an identical 5-metre proximitor configuration. Engineers recommend checking thread engagement depth carefully during installation to prevent bottoming out the 3/8-24 UNF threads inside restricted mounting bores.
Frequently Asked Questions
Q: What operational benefit does the alumina ceramic tip provide over standard polyphenylsulfone tips?
A: The alumina ceramic material offers superior resistance to abrasive slurries, high chemical corrosion, and elevated operating temperatures up to +232°C in gas atmosphere zones.
Q: Why must this 5-metre probe version connect exclusively to a 5-metre proximitor sensor?
A: The system capacitance is precisely calibrated for a fixed 5-metre electrical length; mixing cable lengths alters total circuit resistance and invalidates output voltage scaling.
Q: How does the pressure seal integrity hold up under high-pressure gas applications?
A: The factory seal withstands up to 34 Bar (500 psi) of nitrogen pressure, though custom modifications are available for extreme high-pressure containment requirements.
Q: What precautions should technicians take when installing unarmored probe leads in tight conduits?
A: Technicians must route the coaxial cable away from sharp metal edges and high-voltage power lines to prevent mechanical chafing and electromagnetic noise coupling.
Q: What criteria are essential when selecting replacement ceramic probes for harsh processes?
A: Buyers must verify the exact thread size, case length option, and total length suffix—such as the -08-50 configuration—to match existing mechanical clearances and calibration baselines.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.