Inicio AS3100S2-Z0 Bently Nevada Accelerometer – 100 mV/g Vibration Sensor

AS3100S2-Z0 Bently Nevada Accelerometer – 100 mV/g Vibration Sensor

  • Manufacturer: Bently Nevada

  • Product No.: AS3100S2-Z0

  • Condition: En stock

  • Product Type: Accelerometer

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

AS3100S2-Z0 | Bently Nevada Industrial IEPE Accelerometer

The Bently Nevada AS3100S2-Z0 is an Integrated Electronics Piezo-Electric (IEPE) accelerometer designed for vibration measurement in demanding industrial environments. Its PZT ceramic shear sensing element converts mechanical acceleration into an electrical signal.

An integrated amplifier conditions the sensor signal and provides a voltage output proportional to acceleration. This architecture supports connection to compatible vibration monitoring and condition monitoring systems through a constant-current power supply.

With a nominal sensitivity of 100 mV/g, an acceleration range of 80 g peak, and a specified frequency response extending to 10 kHz at ±3 dB, the sensor supports machinery vibration analysis across a broad measurement range.

01 | Measurement Architecture: From Acceleration to Signal Output

The AS3100S2-Z0 uses a piezoelectric shear sensing element and integrated electronics. When the mounting surface vibrates, the PZT element generates an electrical charge proportional to the applied acceleration. The internal amplifier converts this signal into a low-impedance voltage output.

Signal Chain Element Function
PZT ceramic shear element Detects dynamic mechanical acceleration.
Integrated amplifier Conditions the piezoelectric signal and provides voltage output.
Constant-current excitation Supplies operating power to the IEPE electronics.
Voltage output Provides an acceleration-proportional signal to compatible monitoring equipment.

The IEPE interface reduces sensitivity to electrical interference compared with an unbuffered high-impedance piezoelectric signal. Correct cable shielding, grounding, and excitation remain essential for reliable measurements.

02 | Dynamic Performance and Measurement Range

The sensor's dynamic specifications define its usable acceleration range, sensitivity, frequency response, and linearity. These values help engineers evaluate its suitability for machinery vibration measurements.

Dynamic Parameter Specification
Nominal sensitivity 100 mV/g
Sensitivity tolerance ±5% at 25 °C
Acceleration range 80 g peak
Amplitude nonlinearity 1%
Frequency response, ±10% 1.0–5,000 Hz
Frequency response, ±3 dB 0.7–10,000 Hz
Resonant frequency 22 kHz
Transverse sensitivity Maximum ±5% of axial sensitivity
Temperature response at -55 °C -8%
Temperature response at +120 °C +10%

Engineering interpretation:

  • The 100 mV/g sensitivity converts acceleration into a proportional voltage signal.
  • The 80 g peak range defines the specified acceleration measurement limit.
  • The ±10% frequency band provides a useful reference for measurement accuracy.
  • The wider ±3 dB band describes the sensor's broader frequency response, not a uniform accuracy range.
  • The 22 kHz resonance lies above the specified ±3 dB measurement band.

For condition monitoring, select the measurement bandwidth according to the machine's operating speed, bearing characteristics, gear mesh frequencies, and expected fault signatures.

03 | IEPE Electrical Interface and Signal Conditioning

The integrated electronics require a compatible constant-current excitation source. The monitoring input must also accept the sensor's bias voltage and dynamic output signal.

Electrical Parameter Specification
Supply voltage 18–30 VDC
Current regulating diode 2–10 mA
Output impedance Maximum 100 Ω
Bias output voltage 12 VDC
Grounding arrangement Case isolated, internally shielded
Broadband electrical noise 700 μg, 2.5 Hz to 25 kHz
Spectral noise at 10 Hz 10 μg/√Hz
Spectral noise at 100 Hz 5 μg/√Hz
Spectral noise at 1,000 Hz 5 μg/√Hz

Signal scaling example: At 100 mV/g sensitivity, an acceleration of 1 g produces a nominal 100 mV dynamic signal. An acceleration of 5 g produces approximately 500 mV, subject to the sensor's operating range and signal conditioning.

The 12 VDC bias output is the sensor's normal operating bias, not the acceleration signal amplitude. Monitoring equipment should account for this bias when measuring the dynamic voltage component.

04 | Mechanical Construction and Installation Interface

The sensor uses a corrosion-resistant 316L stainless steel case and a hermetically sealed construction. Its compact mounting arrangement supports permanent installation on machinery and access-limited measurement locations.

Physical Parameter Specification
Sensing element PZT ceramic, shear design
Case material 316L stainless steel
Weight 145 g
Mounting arrangement 1/4-28 captive hex-head screw
Connector position Side exit
Connector type 2-pin MIL-C-5015 style
Sealing Hermetic

Installation guidance:

  1. Choose a rigid measurement location close to the vibration source.
  2. Prepare a clean, flat mounting surface to improve mechanical coupling.
  3. Check the mounting thread and screw engagement before tightening.
  4. Secure the sensor using the approved mounting procedure and torque specification.
  5. Route the cable away from moving components, hot surfaces, and high-current conductors.
  6. Confirm connector engagement and cable shielding before collecting data.

A loose mounting interface can reduce high-frequency response and introduce measurement errors. Avoid mounting the sensor on thin covers or flexible brackets when measuring bearing or housing vibration.

05 | Connector Pinout and Cable Requirements

The side-exit connector uses a two-pin MIL-C-5015-style interface. Correct pin assignment is essential for sensor power and signal acquisition.

Connector Contact Function
Shell Ground
Pin A Power / Signal
Pin B Common

Recommended cable: Use shielded twisted-pair cable with a maximum recommended length of 100 feet.

Keep the cable shield and grounding arrangement consistent with the monitoring system's input design. Avoid unnecessary ground connections that could create ground-loop currents. The sensor's case isolation and internal shielding help reduce this risk, but they do not replace correct system grounding.

06 | Environmental Limits and Industrial Protection

The AS3100S2-Z0 is designed for harsh industrial environments. Its mechanical construction and electrical protection features support installation near operating machinery.

Environmental Parameter Specification
Operating temperature -50 °C to +120 °C
Vibration limit 500 g peak
Shock limit 5,000 g peak
Electromagnetic sensitivity Maximum 70 μg/gauss
Base strain sensitivity Maximum 0.002 g/μstrain
Sealing Hermetic

Protection features:

  • Corrosion-resistant stainless steel construction.
  • Hermetic sealing against environmental ingress.
  • Case isolation to help prevent ground-loop problems.
  • Electrostatic discharge protection.
  • Reverse-wiring protection.
  • EMI and RFI shielding.

The sensor can support washdown or submersion applications when used with a properly rated connector and cable assembly. Confirm the complete connection system's environmental rating before exposure to water.

07 | Machinery Monitoring Applications

The IEPE output allows the sensor to interface with compatible vibration data collectors and permanent monitoring systems. Engineers can use acceleration measurements to investigate machine condition and dynamic behavior.

  • Rotating machinery: Measure casing and housing acceleration on pumps, motors, compressors, and fans.
  • Bearing diagnostics: Capture higher-frequency vibration components associated with bearing condition assessment.
  • Gearbox monitoring: Measure dynamic acceleration around gear housings and transmission structures.
  • Portable vibration routes: Use the relatively low 145 g sensor mass for walk-around measurement programs.
  • Permanent installations: Use the case-isolated design to help reduce ground-loop issues in suitable monitoring arrangements.

For accurate trend comparison, keep sensor location, mounting method, cable routing, and measurement settings consistent across inspection intervals.

08 | Selection and Compatibility Checks

The AS3100 series includes different sensitivity levels, connector orientations, and hazardous-area certification options. Confirm the exact configuration before selecting a replacement or adding a measurement point.

Selection Factor AS3100S2-Z0 Information Verification Required
Sensitivity 100 mV/g Match the monitoring input scaling and required measurement range.
Connector orientation Side exit Check cable clearance and installation access.
Connector type 2-pin MIL-C-5015 style Confirm connector and cable assembly compatibility.
Excitation 18–30 VDC, 2–10 mA Verify constant-current IEPE input support.
Hazardous-area approval Series offers different certification options Confirm the exact approval for the -Z0 configuration.
Frequency range 0.7–10,000 Hz at ±3 dB Compare with the required diagnostic bandwidth.

Important model-code note: The supplied data describes the AS3100 series and identifies the AS3100S2-Z0 as a 100 mV/g, side-exit configuration. It does not specify the exact hazardous-area approval represented by the -Z0 suffix. Do not assign an ATEX, IECEx, or other certification to this exact model without checking its product-specific documentation.

09 | Field Diagnostics and Measurement Quality

Unexpected vibration readings may result from the machine, sensor mounting, cable condition, or signal-conditioning circuit. Check the complete measurement chain before concluding that the sensor has failed.

  • Flat or missing signal: Verify IEPE excitation, cable continuity, connector pin assignment, and monitoring input configuration.
  • Excessive electrical noise: Inspect shield termination, cable routing, grounding, and nearby variable-frequency drives.
  • Low measured amplitude: Check mounting rigidity, sensor orientation, sensitivity scaling, and signal conditioning.
  • Unstable baseline: Inspect the bias voltage and cable connection. Compare the measured bias with the specified nominal 12 VDC value.
  • Inconsistent high-frequency readings: Review mounting surface quality, attachment rigidity, cable movement, and acquisition bandwidth.

For a repeatable baseline, document the sensor location, mounting arrangement, cable type, excitation current, and analyzer settings. This makes trend changes easier to distinguish from measurement setup variations.

10 | Frequently Asked Questions

Q1: How do I convert the AS3100S2-Z0 voltage output into acceleration?

Use the nominal sensitivity of 100 mV/g. Subtract the DC bias component from the measured signal, then divide the dynamic voltage by 100 mV/g. For example, a 200 mV dynamic signal represents approximately 2 g. Apply the correct analyzer scaling and account for the stated sensitivity tolerance.

Q2: Can I connect this sensor directly to a standard voltage input?

Only if the input supports the required IEPE constant-current excitation and can accommodate the sensor's bias voltage. A conventional voltage input without excitation may not power the integrated amplifier. Check the monitoring instrument's IEPE input specifications before connection.

Q3: Why does sensor mounting affect high-frequency vibration measurements?

The mounting interface forms part of the mechanical measurement path. Uneven surfaces, loose fasteners, flexible brackets, or poor contact can reduce the transmitted vibration energy. Use a rigid mounting point and follow the approved mounting procedure to maintain measurement consistency.

Q4: What should I consider when replacing a 500 mV/g accelerometer with this 100 mV/g model?

Check the analyzer's sensitivity setting, input range, signal scaling, and expected acceleration amplitude. At the same acceleration, a 100 mV/g sensor produces one-fifth the voltage of a 500 mV/g sensor. Confirm that the new signal level remains suitable for the monitoring system's noise floor and dynamic range.

Q5: How can I distinguish sensor failure from a cable or input-channel fault?

Inspect the connector and cable first. Verify the constant-current supply and measure the sensor bias voltage using an appropriate test arrangement. If possible, compare the sensor with a known-good channel or compatible sensor. Change one component at a time to isolate the fault without altering the measurement setup unnecessarily.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.