Inicio Q4BCY30D10A Renishaw QUANTiC Incremental Optical Encoder Readhead

Q4BCY30D10A Renishaw QUANTiC Incremental Optical Encoder Readhead

  • Manufacturer: Renishaw

  • Product No.: Q4BCY30D10A

  • Condition: En stock

  • Product Type: Encoder Readhead

  • Product Origin: UK

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

01 | Product Identity – Optical Feedback Technology

Renishaw Q4BCY30D10A is a QUANTiC™ incremental optical encoder readhead for precision linear motion systems. It reads an optical scale and generates incremental position feedback for motion controllers. Its 40 µm scale pitch supports accurate position measurement in industrial automation equipment. The readhead integrates optical signal processing and automatic signal adjustment functions. Its compact design supports machine integration where positioning accuracy and installation flexibility matter. Key identification:

  • Manufacturer: Renishaw
  • Model: Q4BCY30D10A
  • Product Family: QUANTiC™
  • Product Type: Incremental Optical Encoder Readhead
  • Measurement Configuration: Linear
  • Scale Pitch: 40 µm
  • Digital Resolution: 0.1 µm
  • Reference Configuration: Customer-selectable reference mark and limit sensor arrangement

02 | Configuration Breakdown – Decode Every Suffix

The complete order code identifies the readhead configuration and electrical interface. The following table follows the supplied model-code interpretation.

Code Configuration Engineering Description
Q4 Product Family QUANTiC™ series, 40 µm scale pitch
B System Type Linear encoder configuration
C Readhead Version Standard readhead with integrated setup LED
Y Resolution 0.1 µm digital resolution
30 Cable Length 3.0 m standard cable
D Connector 15-pin D-type connector (DB15)
10 Clock Frequency 10 MHz
A Reference / Limit Configuration Customer-selectable reference mark and dual-limit sensor configuration

Complete Configuration:

Q4 → 40 µm QUANTiC™ platform B → Linear measurement system C → Standard readhead with setup LED Y → 0.1 µm digital resolution 30 → 3.0 m cable D → 15-pin D-type connector 10 → 10 MHz clock frequency A → Reference and limit sensor configuration

Important Selection Note: Confirm the complete suffix against the official Renishaw ordering documentation. Verify the required reference and limit functions before placing an order.

03 | Optical Performance – Position Feedback Specifications

Parameter Specification
Measurement Technology Incremental optical sensing
Measurement Direction Linear
Scale Pitch 40 µm
Digital Resolution 0.1 µm (100 nm)
Maximum Series Speed Up to 24 m/s, subject to resolution and clock configuration
Clock Frequency 10 MHz
Supply Voltage 5 V DC
Typical Current Consumption Approximately 150 mA
Installation Height Tolerance ±0.3 mm
Angular Installation Tolerance ±0.9°
Signal Adjustment AGC, ABC and AOC
Setup Indicator Integrated LED
Cable Length 3.0 m
Electrical Connector 15-pin D-type

Performance Interpretation:

  • 100 nm Resolution: Provides fine digital position increments for precision motion feedback.
  • 10 MHz Clock: Defines an important part of the digital interface and maximum speed capability.
  • 24 m/s Series Capability: Represents the stated QUANTiC family maximum, not a guaranteed speed at every resolution.
  • Installation Tolerance: Reduces sensitivity to minor mounting variations.
  • Signal Conditioning: Helps maintain stable optical feedback during normal operating conditions.

Note: Resolution represents the digital measurement increment. It does not independently define system accuracy, repeatability or measurement uncertainty.

04 | Intelligent Signal Control – AGC, ABC and AOC

The QUANTiC™ readhead integrates three automatic signal adjustment functions.

Technology Engineering Function
AGC Automatic Gain Control adjusts signal amplitude.
ABC Automatic Balance Control maintains signal balance.
AOC Automatic Offset Control compensates for signal offset.

These functions help maintain usable optical signals under changing operating conditions. They also reduce sensitivity to minor optical contamination and signal variations. However, they do not eliminate the need for scale cleaning and correct mechanical alignment.

05 | Mechanical Integration and Installation

Compatible Linear Scale Families:

  • RTLC40
  • RTLC40-S
  • RKLC40-S

Installation Sequence:

  1. Confirm the scale model and 40 µm pitch compatibility.
  2. Inspect the mounting surface for contamination and mechanical damage.
  3. Position the readhead according to the applicable installation drawing.
  4. Set the required readhead-to-scale installation height.
  5. Maintain the specified ±0.3 mm height tolerance.
  6. Check angular alignment within the specified ±0.9° tolerance.
  7. Connect the 15-pin interface to the compatible controller.
  8. Provide a stable 5 V DC supply.
  9. Use the integrated LED to assist setup and alignment checks.
  10. Move the axis slowly and verify stable position feedback.

Engineering Recommendation: Avoid excessive cable bending and mechanical stress at the connector. Secure the cable away from motor power cables and high-frequency switching sources.

06 | Controller Integration and Electrical Considerations

The Q4BCY30D10A provides incremental digital position feedback. Before connecting it to a motion controller, verify the following:

  • Supply Compatibility: The controller must provide the specified 5 V DC supply.
  • Connector Compatibility: Confirm the 15-pin D-type interface and pin assignment.
  • Input Compatibility: Verify the controller accepts the readhead's output signal format.
  • Clock Compatibility: Check the 10 MHz interface configuration.
  • Resolution Settings: Configure the controller for 0.1 µm resolution.
  • Reference Processing: Confirm the controller supports the selected reference mark arrangement.
  • Limit Inputs: Verify the required limit sensor functions and input assignments.

Do not connect the readhead based on connector shape alone. Confirm the electrical interface and pinout before commissioning.

07 | Maintenance and Diagnostic Recommendations

Observed Condition Recommended Inspection
Unstable position feedback Inspect optical surfaces, alignment and cable connections.
Reference position failure Check reference mark configuration and controller settings.
Intermittent signal loss Inspect cable routing, connector contacts and supply stability.
Unexpected position counts Verify resolution settings and controller signal compatibility.
Setup LED indicates an issue Follow the applicable Renishaw setup and diagnostic instructions.

Maintenance Practice: Keep the optical scale clean and inspect the cable periodically. Avoid abrasive cleaning materials and excessive mechanical force.

08 | Application Areas

  • CNC Machine Tools: Linear axis position feedback and motion control.
  • Precision Automation: Position monitoring in automated production equipment.
  • Semiconductor Equipment: High-resolution linear positioning applications.
  • Metrology Systems: Position feedback for precision measurement platforms.
  • Robotics: Linear actuator and positioning mechanism feedback.
  • Industrial Motion Systems: Closed-loop position control and axis monitoring.

09 | Purchasing, Warranty and Delivery

Product Renishaw QUANTiC™ Optical Encoder Readhead
Order Model Q4BCY30D10A
Product Configuration 40 µm pitch / 0.1 µm resolution / 3.0 m cable
Warranty 12 Months
Shipping Options FedEx / UPS / DHL
Order Verification Model number and configuration confirmation before dispatch

Warranty Terms: Includes a 12-month warranty against covered product defects under the applicable sales terms. Contact our sales team for warranty conditions and claim procedures. Shipping: International delivery options include FedEx, UPS and DHL. Dispatch arrangements depend on stock status and order confirmation.

10 | Technical FAQ – Selection and Engineering Experience

Q1: How should engineers select the correct scale for this readhead? Start with the 40 µm scale pitch requirement. Then check the mechanical mounting arrangement, scale length and operating environment. Confirm compatibility with RTLC40, RTLC40-S or RKLC40-S before ordering.

Q2: Does 0.1 µm resolution mean the machine achieves 0.1 µm positioning accuracy? No. Resolution describes the smallest digital position increment. Actual positioning accuracy also depends on scale accuracy, mechanical stiffness, thermal expansion, controller performance and installation quality.

Q3: What should be checked when the encoder works at low speed but fails at high speed? Check the controller input frequency limit first. Then verify the selected resolution, clock configuration and signal integrity. Excessive cable interference or an incompatible receiver can also affect high-speed operation.

Q4: Is a 3-meter cable suitable for every machine installation? Not necessarily. Measure the complete cable route before ordering. Include cable routing, connector access and maintenance clearance. Avoid unnecessary extensions or unverified cable modifications.

Q5: What information should buyers confirm before purchasing Q4BCY30D10A? Confirm the 40 µm scale pitch, linear configuration, 0.1 µm resolution and 3-meter cable. Also verify the DB15 interface, controller compatibility and reference or limit requirements. Compare the complete ordering code with the installed readhead to avoid configuration mismatches.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.