Inicio RGS40-S Renishaw 40µm Gold Steel Encoder Tape

RGS40-S Renishaw 40µm Gold Steel Encoder Tape

  • Manufacturer: Renishaw

  • Product No.: RGS40-S

  • Condition: En stock

  • Product Type: Linear Encoder Scale

  • Product Origin: UK

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

Renishaw RGS40-S | RG4 Series 40 µm Precision Linear Encoder Scale

The Renishaw RGS40-S is a reflective, gold-plated steel tape scale designed for high-accuracy incremental linear measurement. It belongs to the RGS40 scale family and provides a 40 µm graduation pitch.

Its thin steel construction follows the thermal expansion behavior of the mounting substrate. This characteristic helps maintain measurement stability across changing machine temperatures.

The integrated adhesive backing supports direct installation on prepared metal, granite, ceramic, and composite surfaces. Epoxy-mounted end clamps secure the scale without requiring substrate drilling.

The RGS40-S works with compatible Renishaw RGH34 and RGH41 readheads. It suits precision machine tools, semiconductor positioning stages, coordinate measurement equipment, and automated inspection systems.

01 | Product Identity and Technical Specifications

Specification Technical Details
Manufacturer Renishaw
Model RGS40-S
Product Family RGS40
Encoder System RG4 Series Compatible Linear Encoder System
Product Type Reflective Gold-Plated Steel Tape Scale
Measurement Principle Incremental Optical Linear Measurement
Scale Pitch 40 µm
Scale Material Flexible steel tape
Surface Finish Gold-plated reflective surface with protective lacquer
Backing Specially formulated self-adhesive backing
Width 6 mm
Thickness Approximately 0.2 mm, including adhesive
Linearity ±3 µm/m; ±1 µm over 60 mm
Standard Supply Length 100 mm to 50 m
Extended Length Above 50 m by special order
Operating Temperature -10 °C to +120 °C
Minimum Installation Temperature +10 °C
Compatible Readheads RGH34 and RGH41

02 | Configuration Breakdown and Construction

The RGS40-S designation identifies a specific 40 µm steel tape scale configuration. It does not use the same suffix structure as electronic readhead models.

  • RGS40
    • RGS: Renishaw reflective steel tape scale family.
    • 40: 40 µm incremental scale pitch.
  • S
    • Protective lacquer surface finish.
    • Gold-plated reflective steel construction.
    • Self-adhesive mounting backing.

Construction Layers:

Layer Engineering Function
Reflective Surface Provides the optical surface for readhead scanning.
Protective Lacquer Protects the reflective surface during normal operation.
Steel Substrate Provides a thin, flexible dimensional reference.
Adhesive Backing Secures the scale to the prepared machine surface.

03 | Thermal Behavior and Measurement Accuracy

The RGS40-S uses a thin-section steel construction. Its thermal behavior follows the mounting substrate after proper installation and end fixing.

  • Linearity: ±3 µm/m under specified measurement conditions.
  • Local Linearity: ±1 µm over a 60 mm measuring length.
  • Thermal Matching: The installed scale follows the substrate expansion coefficient.
  • Substrate Compatibility: Suitable materials have expansion coefficients between 0 and 22 µm/m/°C.
  • End Fixing: Epoxy-mounted clamps prevent uncontrolled scale-end movement.
  • Thermal Stability: End movement remains below 1 µm over -20 °C to +50 °C.

This thermal arrangement reduces differential movement between the scale and machine structure. It supports repeatable measurements during normal machine temperature changes.

Engineering Consideration: Scale linearity describes the scale itself. Complete machine accuracy also depends on readhead performance, mounting geometry, controller interpolation, and mechanical positioning errors.

04 | Installation Architecture and Mounting Accessories

The adhesive-backed design eliminates the need for mounting holes along the scale path. The installation surface must provide adequate flatness, cleanliness, and adhesion.

Recommended Installation Sequence:

  1. Inspect the mounting surface for scratches, burrs, and contamination.
  2. Confirm the substrate expansion coefficient falls within the specified range.
  3. Clean and prepare the mounting surface according to Renishaw instructions.
  4. Allow the scale and substrate to reach the installation temperature.
  5. Align the tape with the machine's intended measurement axis.
  6. Apply the adhesive-backed scale without trapping air or creating wrinkles.
  7. Secure both scale ends with epoxy-mounted end clamps.
  8. Install the compatible readhead and verify its alignment.
  9. Check incremental signals and reference positioning during commissioning.

End-Fixing Components:

Accessory Function
A-9523-4015 Epoxy-mounted scale end clamps.
A-9531-0342 Two-part epoxy adhesive for end fixing.

05 | Reference Mark and Limit Switch Configuration

The RGS40-S system supports additional magnetic actuators for reference positioning and travel-limit detection. These accessories work with compatible sensing functions inside the readhead.

A. Reference Mark Actuators

Part Number Mounting Configuration Application
A-9531-0250 Adhesive / epoxy mounted Magnetic reference actuator
A-9531-0287 Screw mounted Magnetic reference actuator
A-9541-0037 90° adhesive or screw mounted Reference actuator for RGH24, RGH25, and RGH34
  • Install one or more reference actuators at selected axis positions.
  • The magnetic actuator establishes a repeatable machine datum.
  • The reference output synchronizes with incremental channels.
  • Unidirectional repeatability remains specified within the applicable operating conditions.

Reference Repeatability Conditions:

Parameter RGS40-S Requirement
Temperature Variation ±20 °C from installation temperature
Magnetic Field Steady ±0.02 T or changing ±7.5 T/s
Operating Speed Refer to the applicable readhead specification

B. Limit Switch Actuators

Part Number Actuator Type
A-9531-0251 10 mm adhesive-mounted magnetic actuator
A-9531-2052 24.35 mm adhesive-mounted magnetic actuator
A-9531-2054 50 mm adhesive-mounted magnetic actuator
A-9531-0285 Flush-mounted magnetic actuator
A-9541-0040 90° adhesive or screw-mounted actuator

Limit Detection Characteristics:

  • Detection Method: Magnetic actuator sensing.
  • Position: One or more selected travel positions.
  • Repeatability: 0.1 mm.
  • Purpose: Provides position-related limit detection for compatible control systems.

Compatibility Warning: Actuator mounting and sensing arrangements vary by readhead model. Confirm the accessory part number against the exact RGH34 or RGH41 configuration before ordering.

06 | Readhead Compatibility and System Selection

Component Compatible Configuration Selection Notes
RGH34 40 µm RGS40-S scale Confirm output and reference options.
RGH41 40 µm RGS40-S scale Confirm electrical interface and actuator arrangement.
RGH22 Not the specified pairing Designed for the 20 µm RGS20 scale family.
RGH24 / RGH25 Not the specified pairing Check the corresponding scale family before selection.

Important Selection Rule: Match the scale pitch with the readhead's optical system. A 40 µm scale requires the corresponding RGS40-compatible readhead configuration.

07 | RGS40-S vs. RGS40-PC: Material Selection

Comparison RGS40-S RGS40-PC
Scale Pitch 40 µm 40 µm
Base Material Gold-plated steel Gold-plated steel
Surface Protection Protective lacquer Protective polyester coating
Linearity ±3 µm/m ±5 µm/m
Local Linearity ±1 µm/60 mm ±1.5 µm/60 mm
Readhead Compatibility RGH34, RGH41 RGH41
Recommended Selection Standard precision applications Applications requiring improved chemical resistance

Choose RGS40-S when scale linearity is the primary selection requirement. Consider RGS40-PC when exposure to harsh solvents requires additional surface protection.

08 | Environmental and Maintenance Requirements

  • Operating Temperature: -10 °C to +120 °C for the scale.
  • Installation Temperature: Minimum +10 °C.
  • Substrate: Compatible metals, granite, ceramics, and composites.
  • Surface Condition: Clean, stable, and suitable for adhesive bonding.
  • Chemical Exposure: Avoid aggressive solvents on the lacquered surface.
  • Inspection: Check for adhesive lifting, surface damage, and contamination.

Use compatible cleaning materials and follow the manufacturer's installation instructions. Avoid acetone, chlorinated solvents, and methylated spirits on the scale.

For applications involving aggressive solvents or lubricants, evaluate the RGS40-PC polyester-coated alternative.

09 | Certification and Documentation

The supplied specifications identify the material, dimensions, measurement pitch, and operating limits. They do not establish a separate product-specific certification declaration.

  • Request the applicable Renishaw technical datasheet.
  • Confirm installation requirements against the official scale guide.
  • Verify machine-level compliance with the relevant industrial standards.
  • Request product identification and traceability documentation when required.

10 | Package Contents and Supply Options

  • 1 × Renishaw RGS40-S reflective steel tape scale.
  • Specified cut length according to the purchase order.
  • Self-adhesive backing supplied with the scale.

Ordering Information:

  • Cut-to-length supply from 100 mm to 50 m.
  • Lengths above 50 m require special-order confirmation.
  • Reference actuators and limit actuators require separate selection.
  • End clamps and epoxy adhesive should be specified separately.
  • Readheads are not included unless the order explicitly states otherwise.

11 | Engineering FAQ and Purchasing Guidance

Q1: How should engineers calculate the required RGS40-S scale length?

Start with the machine's measuring travel, then check the readhead's installation geometry and end-fixing allowance. The complete scale length must accommodate the measuring range and required installation margins. Do not order using the nominal axis travel alone.

Q2: What happens if the mounting surface has poor flatness?

Local surface irregularities can affect tape adhesion and readhead alignment. They may also introduce unwanted ride-height variation. Inspect and prepare the substrate before applying the scale. Follow the readhead installation drawing for surface and alignment tolerances.

Q3: Can the RGS40-S be installed on an aluminum machine bed?

Yes, provided the substrate meets the specified expansion-coefficient range and installation requirements. The thin tape follows the substrate's thermal behavior after correct bonding and end fixing. Always verify the actual machine material and mounting conditions.

Q4: When should a machine builder select RGS40-PC instead?

Choose RGS40-PC when the scale faces greater exposure to aggressive cleaning chemicals or lubricants. Its polyester coating improves chemical resistance. However, its specified linearity differs from RGS40-S. Compare measurement requirements before changing the material configuration.

Q5: What information should buyers provide when requesting a replacement scale?

Provide the existing scale model, required measuring length, readhead model, substrate material, and operating temperature. Also identify the required reference and limit functions. These details help prevent pitch mismatches and incorrect accessory selection.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.