Inicio Q4BCW30D12A Renishaw QUANTiC Linear Encoder Readhead

Q4BCW30D12A Renishaw QUANTiC Linear Encoder Readhead

  • Manufacturer: Renishaw

  • Product No.: Q4BCW30D12A

  • Condition: En stock

  • Product Type: Encoder Readhead

  • Product Origin: UK

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

Renishaw QUANTiC™ | Digital Position Feedback for Precision Linear Motion

Q4BCW30D12A is a digital incremental optical encoder readhead from the Renishaw QUANTiC™ Q4 series. It provides precise position feedback for industrial linear motion systems.

This configuration combines a 40 μm scale pitch, 0.2 μm digital resolution, and a 12 MHz clocked output. Its 3-meter cable terminates with a 15-way D-type connector. The readhead supports compatible RTLC40, RTLC40-S, and RKLC40-S linear scales.

The QUANTiC architecture integrates optical sensing, signal processing, and reference mark functionality. It supports accurate incremental position measurement in demanding automation environments. Engineers can integrate this encoder into precision stages, measuring equipment, and automated positioning systems.

01 | Product Identity & Configuration Architecture

Manufacturer Renishaw
Complete Model Q4BCW30D12A
Product Series QUANTiC™ Q4
Product Type Digital Incremental Optical Linear Encoder Readhead
Measurement Method Non-contact optical incremental measurement
Scale Pitch 40 μm
Digital Resolution 0.2 μm (200 nm)
Cable Length 3 meters
Connector 15-way D-type plug, standard pin-out
Clocked Output 12 MHz
Reference Mark Customer selectable
Alarm Format Line-driven alarm

02 | Part Number Breakdown – Decode Every Configuration

The complete ordering code identifies the encoder's mechanical, optical, electrical, and signal configurations.

Code Configuration Engineering Description
Q4 Series QUANTiC 40 μm encoder family
B Readhead Type Standard linear readhead
C Scale Compatibility RTLC40 / RTLC40-S / RKLC40-S
W Digital Resolution 0.2 μm (200 nm)
30 Cable Length 3 meters
D Connector 15-way D-type plug, standard pin-out
12 Clocked Output 12 MHz
A Reference / Alarm Customer selectable reference mark and line-driven alarm

Complete Configuration:

Q4 → 40 μm QUANTiC series

└── B → Linear readhead

    └── C → RTLC40-compatible scale configuration

        └── W → 0.2 μm digital resolution

            └── 30 → 3 m cable

                └── D → 15-way D-type standard pin-out

                    └── 12 → 12 MHz clocked output

                        └── A → Selectable reference mark / line-driven alarm

This configuration structure helps engineers distinguish electrical interface requirements from scale compatibility and resolution options.

03 | Optical Measurement & Digital Signal Characteristics

Encoder Technology Optical incremental encoding
Readhead Architecture Non-contact optical system
Scale Pitch 40 μm
Digital Resolution 0.2 μm
Clock Frequency 12 MHz
Output Type Digital incremental, RS422 interface family
Reference Function Customer selectable reference mark
Alarm Function Line-driven alarm output
Scale Reading Compatible 40 μm linear scale

Resolution and Accuracy: The 0.2 μm value represents the configured digital position resolution. It does not represent absolute measurement accuracy. Actual positioning performance also depends on scale installation, machine geometry, controller processing, and mechanical stability.

04 | Scale Compatibility & Mechanical Integration

The Q4BCW30D12A is designed for the following 40 μm linear scale configurations:

  • RTLC40: Compatible 40 μm linear scale.
  • RTLC40-S: Compatible 40 μm stainless steel scale.
  • RKLC40-S: Compatible 40 μm steel tape scale.

These scale options provide different mechanical installation possibilities. Select the scale according to travel length, substrate material, mounting geometry, and environmental conditions.

Before installation, verify the scale's mechanical condition and mounting reference. Check the readhead alignment against the manufacturer's specified installation tolerances.

05 | Reference Mark & Alarm Configuration

Customer Selectable Reference Mark

The A configuration supports reference mark selection. A selector magnet activates the required reference position. This function is useful when a scale contains multiple IN-TRAC reference marks.

Engineers can select a specific reference position for machine homing. This arrangement supports applications with multiple possible reference locations.

Line-Driven Alarm

The configured alarm output uses a line-driven format. It provides an alarm indication when the encoder detects an applicable signal condition. The receiving controller must support the corresponding alarm interface.

Important: Only the calibrated reference mark provides bidirectional repeatability. Follow the manufacturer's reference mark setup procedure during commissioning.

06 | Installation & Commissioning Workflow

Stage 1 – Mechanical Preparation

  • Inspect the linear scale and mounting substrate.
  • Remove contamination from the installation surface.
  • Check the scale position and mounting stability.
  • Verify the readhead mounting arrangement.

Stage 2 – Optical Alignment

  • Position the readhead according to Renishaw installation instructions.
  • Maintain the specified readhead-to-scale relationship.
  • Check the optical signal during initial alignment.
  • Secure the readhead after confirming alignment.

Stage 3 – Electrical Connection

  • Confirm the 15-way D-type connector configuration.
  • Check the controller's RS422 interface compatibility.
  • Verify the required 12 MHz clocked output support.
  • Confirm the reference and alarm input assignments.

Stage 4 – Functional Testing

  • Move the axis through a controlled travel distance.
  • Verify incremental counting and direction detection.
  • Test the selected reference mark response.
  • Check alarm signal recognition at the controller.
  • Compare encoder feedback against an independent position reference.

07 | Maintenance & Diagnostic Recommendations

  • Position Drift: Check scale mounting stability and machine thermal behavior.
  • Signal Interruption: Inspect the cable, connector, and controller interface.
  • Incorrect Homing: Verify selector magnet position and reference mark configuration.
  • Unexpected Alarm: Check optical alignment and alarm input wiring.
  • Counting Errors: Review signal integrity, controller clock compatibility, and scale condition.

Regular inspection helps maintain stable encoder feedback. Avoid unnecessary mechanical adjustments before checking electrical signals and alignment conditions.

08 | Engineering Applications

  • Precision Linear Stages: Provides incremental position feedback for controlled axis movement.
  • CNC Equipment: Supports accurate feedback in compatible linear positioning systems.
  • Metrology Machines: Supplies digital position information for measurement equipment.
  • Semiconductor Equipment: Supports precision positioning in automated production systems.
  • Automated Inspection Systems: Provides repeatable position feedback for scanning and inspection axes.
  • Industrial Motion Platforms: Integrates with compatible digital motion controllers.

09 | Compatibility & Replacement Selection

When selecting a replacement for an existing encoder, verify these five engineering parameters:

  1. Scale Pitch: Confirm the existing scale uses a 40 μm pitch.
  2. Resolution: Match the required 0.2 μm digital resolution.
  3. Connector: Verify the 15-way D-type standard pin-out.
  4. Clocked Output: Confirm controller support for 12 MHz.
  5. Reference Configuration: Verify customer selectable reference marks and line-driven alarm requirements.

Do not replace an encoder based only on the QUANTiC series name. Different readhead configurations can have different resolutions, connectors, clock frequencies, and reference options.

10 | Warranty, Quality & Global Shipping

Warranty Period 12 months
Product Verification Model and configuration verification
Technical Support Product selection and compatibility assistance
Shipping Carriers FedEx, UPS, DHL
Application Support Industrial automation and precision motion systems

Our team supports industrial encoder procurement and replacement projects. Contact us to confirm the exact model configuration, availability, and quotation details.

11 | Frequently Asked Questions

Q1: What is the difference between incremental and absolute encoder feedback?

An incremental encoder measures relative movement through digital signal transitions. The controller establishes the machine coordinate through a reference procedure. An absolute encoder provides a coded position value without requiring the same incremental homing process.

Q2: Why must the controller support the encoder's clock frequency?

The clocked output configuration affects signal communication and processing compatibility. An incompatible controller interface may fail to decode the encoder signals correctly. Verify the 12 MHz specification against the controller's supported input requirements.

Q3: When should engineers use a selectable reference mark instead of outputting every reference mark?

A selectable reference mark suits applications with multiple reference locations. It allows a designated reference position to be activated through a selector magnet. Applications with one reference position may use an all-reference-mark configuration instead.

Q4: How can engineers determine whether a replacement readhead will work with an existing scale?

Check the scale pitch, scale family, readhead compatibility code, and mounting arrangement. The 40 μm pitch alone does not establish complete compatibility. Confirm the valid readhead and scale combination using Renishaw system configuration documentation.

Q5: What should buyers consider when choosing between 0.2 μm and finer encoder resolutions?

Evaluate the required positioning tolerance and the machine's mechanical performance. Finer resolution increases the number of reported position increments. However, it cannot compensate for backlash, structural deformation, thermal expansion, or poor scale installation. Select the resolution according to the complete machine specification.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.