VBS01-EPD HN800 Analog Digital I/O Termination Base
Manufacturer: ABB
Product No.: VBS01-EPD
Condition: In stock
Product Type: Termination Base
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview
The VBS01-EPD is a full-size mounting base for the HN800 I/O system. It provides field signal termination for Singular Analog and Digital I/O modules.
This base supports up to 16 process signal channels within one horizontal I/O row. It accommodates externally powered field signals and differential input configurations.
Two 16-point headers provide the field signal interface. Users can connect two pluggable terminal blocks directly to field wiring. Alternatively, SPK0x_-yy marshaling cables connect the base to third-party termination hardware.
The VBS01-EPD supports vertical column installation on standard 35 mm DIN rails. Its latching mechanism secures the base during installation and operation.
Key Features and Functional Benefits
- 16-channel termination: Supports up to 16 analog or digital process signals.
- Dual connection headers: Provides two pluggable 16-point terminal block interfaces.
- Flexible field wiring: Supports direct wiring and external marshaling arrangements.
- HN800 bus integration: Connects compatible I/O modules to the HN800 bus architecture.
- DIN-rail mounting: Uses standard 35 mm DIN rails with an integrated locking mechanism.
- Field power protection: Includes a 5.0 A field power fuse for the entire base.
- Mechanical keying: Optional keying prevents incorrect I/O module insertion.
- Industrial environment: Supports operating temperatures from -40°C to +70°C.
Technical Specifications
| Brand | ABB / HN800 I/O System |
| Model | VBS01-EPD |
| Article Number | VBS01-EPD |
| Product Type | I/O Mounting Base and Field Termination Base |
| I/O Configuration | Singular |
| Supported Channels | 16 channels |
| Supported Signal Types | Analog I/O and Digital I/O |
| Redundancy Architecture | Redundant HN800 I/O Bus |
| Form Factor | Full-size |
| Dimensions | 218 × 67.5 × 114 mm (H × W × D) |
| Weight | 327 g |
| Mounting Orientation | Vertical column mounting |
| Mounting Rail | 35 mm DIN rail |
| HN800 Bus Length | 305 mm |
| Hot-Swap Capability | No |
| Field Power Fusing | 5.0 A for the entire base |
| Field Power Connection | Compact |
| Maximum Current | HBX01L/HBX01R pair: 3.0 A maximum at +24 VDC |
| Signal Connections | 2 × pluggable 16-point terminal blocks |
| Supported Wire Sizes | #22–14 AWG stranded or solid; #12 AWG stranded |
| Galvanic Isolation Test | 1500 V for up to 1 minute |
| Overvoltage Category | Category I for power |
| MTBF | 8,757,234 hours (MIL-HDBK-217-FN2) |
| MTTR | 8 hours |
| Protection Class | IP20 |
Supported I/O Modules
The VBS01-EPD supports the following Singular I/O module families:
- Analog Input: AI01, AI02, AI05, AD01, AD02, AD11
- Analog Output: AO01, AO02
- Digital Input: DI01, DI02, DI03, DI04
- Digital Output: DO01, DO02, DO05
- Additional Listed Module: PI01
Check the specific module's hardware documentation before installation. Confirm its terminal assignment and electrical requirements.
Signal and Measurement Characteristics
The VBS01-EPD provides physical signal termination. It does not perform independent signal measurement or conversion.
| Measurement Range | Depends on the installed I/O module and field instrument. |
| Frequency Response | Defined by the connected I/O module. |
| Sensitivity | Determined by the installed analog input module. |
| Linearity | Determined by the connected I/O module. |
| Resolution | Depends on the installed analog or digital I/O module. |
| Signal Configuration | Supports externally powered and differential field signal arrangements. |
| Channel Capacity | 16 process signal channels. |
Environmental and EMC Specifications
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | 20%–95% at 40°C, non-condensing |
| Operational Vibration | 5–60 Hz: 0.137 mm; 60–150 Hz: 1.0 G |
| Transportation Vibration | 10–500 Hz |
| Storage Shock | 15 G, 11 ms |
| Drop Resistance | 100 mm |
| Operating Altitude | Up to 3,048 m |
| Storage Altitude | Up to 12,192 m |
| Protection Rating | IP20 according to EN 60529 |
| Air Quality | ISA S71.04 G1 |
| Enhanced Air Quality Option | G3-compliant VBS01-EPDA version available |
EMC Immunity:
- ESD immunity: IEC/EN 61000-4-2, Severity Level 3.
- Surge immunity: IEC/EN 61000-4-5, Severity Level 3.
- Electrical fast transient immunity: IEC/EN 61000-4-4, Severity Level 3.
- Radiated RFI immunity: IEC/EN 61000-4-3, Severity Level 3.
- Conducted immunity: IEC/EN 61000-4-6, Severity Level 3.
- Magnetic field immunity: IEC/EN 61000-4-8, Severity Level 4.
- Voltage dips and interruptions: IEC/EN 61000-4-11.
EMC Emissions: Complies with IEC/EN 61000-6-4 and CISPR 11 requirements. The equipment falls under Group 1, Class A.
Installation Guidelines
- Verify the hardware: Confirm the base model and installed I/O module type.
- Prepare the DIN rail: Use a standard 35 mm DIN rail.
- Mount the base: Position the VBS01-EPD vertically and engage its locking latch.
- Check mechanical keying: Verify the keying arrangement before inserting the I/O module.
- Connect field wiring: Use the two 16-point terminal block interfaces.
- Check wire sizes: Follow the specified AWG limits and terminal requirements.
- Verify field power: Check polarity, supply voltage, and the 5.0 A base fuse.
- Inspect the installation: Confirm terminal security and wiring identification.
Important: The VBS01-EPD does not support hot swapping. Isolate the relevant power sources before removal or replacement. Follow the system manufacturer's approved maintenance procedure.
Commissioning and Maintenance
- Pre-start inspection: Check the DIN-rail latch, terminal blocks, and module seating.
- Wiring verification: Confirm each field signal against the approved loop drawings.
- Power verification: Check the field power supply and fuse rating.
- Signal testing: Verify channel operation through the installed I/O module and control system.
- Connection inspection: Check for loose terminals, damaged conductors, and corrosion.
- Replacement planning: Isolate power before removing the base or connected modules.
The modular terminal arrangement simplifies field wiring inspection. However, maintenance personnel must verify signal assignments before reconnecting cables.
Compatibility and System Integration
The HN800 architecture supports mixed I/O configurations. Singular and Redundant modules can operate alongside Compact and Full-size modules on a common HN800 I/O bus.
- Bus architecture: Designed for integration with the HN800 I/O bus.
- Module configuration: Supports the listed Singular analog and digital I/O modules.
- Field termination: Accepts two pluggable 16-point terminal blocks.
- Marshaling interface: Supports SPK0x_-yy marshaling cables.
- System expansion: Allows mixed I/O module arrangements within a common bus architecture.
Mechanical compatibility does not guarantee identical electrical connections. Always verify module type, bus configuration, terminal assignments, and system revision before installation.
Certifications and Compliance
- CSA: Certified for ordinary, non-hazardous locations.
- CSA Class I, Division 2: Groups A, B, C, and D nonincendive hazardous locations.
- CE: EMC and Low Voltage Directive compliance as specified in the product documentation.
- RoHS: Directive 2015/863.
- WEEE: Directive 2012/19/EU.
- Electrical Safety: IEC/EN 61010-1 testing for power overvoltage category I.
- Environmental Testing: Includes IEC/EN 60068 and MIL-STD-810G test requirements.
Verify the applicable certification markings against the delivered product and its documentation.
Package Contents
- 1 × VBS01-EPD I/O mounting base.
Terminal blocks, marshaling cables, I/O modules, and other accessories require separate confirmation. Please specify your installation requirements when requesting a quotation.
Frequently Asked Questions
Q1: What is the primary function of the VBS01-EPD?
The VBS01-EPD provides field signal termination for compatible HN800 analog and digital I/O modules. It supports up to 16 process signal channels.
Q2: Can the VBS01-EPD support both analog and digital signals?
Yes. It supports the listed Analog Input, Analog Output, Digital Input, and Digital Output modules. Check the specific module's wiring requirements before installation.
Q3: Can I replace the VBS01-EPD while the system remains powered?
No. The specified hot-swap capability is unavailable. Isolate the relevant power sources before replacing the base. Follow the approved system maintenance procedure.
Q4: What should engineers check when a field signal fails?
First, inspect the terminal connections and field wiring. Then check field power, fuse condition, and channel assignments. Compare the signal at the termination point with the I/O module diagnostics. This sequence helps separate wiring faults from module faults.
Q5: Can the VBS01-EPD connect to third-party termination hardware?
Yes. The base supports SPK0x_-yy marshaling cables. These cables connect field signals to third-party termination hardware. Confirm the cable type and pin assignment before ordering.
Q6: What is the difference between VBS01-EPD and VBS01-EPDA?
The VBS01-EPD specifies ISA S71.04 G1 air quality compliance. The VBS01-EPDA provides a G3-compliant version for more demanding industrial environments. Confirm the required environmental classification before purchasing.
Q7: Can I use the VBS01-EPD with Redundant I/O modules?
The HN800 platform supports mixed Singular and Redundant configurations. However, this base carries a Singular designation. Confirm the exact base and module combination against the system hardware documentation before installation.
Q8: What information should I provide when ordering a VBS01-EPD?
Provide the complete model number, installed I/O module type, HN800 bus configuration, and required environmental classification. Also confirm whether your application needs direct terminal blocks or marshaling cables. These details help prevent hardware selection errors.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.



