RDIO-01 ABB ACS800 Digital I/O Extension Module
Manufacturer: ABB
Product No.: RDIO-01
Condition: In stock
Product Type: Digital I/O Extension Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
ABB RDIO-01 Digital I/O Extension Module
The ABB RDIO-01 expands the digital signal interface of compatible ABB drives. It provides three digital inputs and two relay outputs for drive status monitoring, external control signals, and relay-based interlocking.
The module accepts both DC and AC input signals. Its inputs support 24–250 V DC or 110–230 V AC, allowing integration with different industrial control circuits. Two relay outputs handle switching duties for external devices and control systems.
Designed for compatible ABB drive platforms, the RDIO-01 digital I/O extension module installs into an RMIO board option slot or an external AIMA-01 I/O Module Adapter. A 38-pin connector establishes the module's signal and power connection.
01 | I/O Architecture at a Glance
| Interface | Quantity | Electrical Capability |
|---|---|---|
| Digital inputs | 3 | 24–250 V DC or 110–230 V AC |
| Relay outputs | 2 | Up to 250 V AC or 120 V DC |
| DC input logic | — | ON above 12 V; OFF below 8 V |
| AC input logic | — | ON above 40 V; OFF below 20 V |
| Input filtering | Selectable | ON: 5–10 ms; OFF: 2 ms |
| Input update interval | — | Minimum 12 ms in ACS800 Standard Application Program |
| Isolation voltage | — | 2.5 kV AC; 1.5 kV AC between DI2 and DI3 |
02 | Digital Input Performance
Three input channels accept industrial AC or DC signals. Their electrical thresholds support reliable state recognition within the specified input range.
| Parameter | Specification |
|---|---|
| DC input voltage | 24–250 V DC |
| AC input voltage | 110–230 V AC ±10% |
| DC input current | 4–10 mA |
| AC input current | Maximum 4 mA |
| DC logic 0 | Below 8 V |
| DC logic 1 | Above 12 V |
| AC logic 0 | Below 20 V |
| AC logic 1 | Above 40 V |
| Filter time | ON: 5–10 ms; OFF: 2 ms |
Each input has a selectable hardware-filter setting. Three green LEDs indicate the individual input states.
Isolation arrangement:
- DI1 has galvanic isolation from DI2, DI3, relay outputs, and the power supply.
- DI2 and DI3 form a separate isolation group.
- DI2 and DI3 also have galvanic isolation from each other.
- Isolation test voltage: 2.5 kV AC for DI1 and the DI2/DI3 group.
- Isolation test voltage between DI2 and DI3: 1.5 kV AC.
03 | Relay Output and Contact Specifications
The two relay channels, RO1 and RO2, provide isolated switching interfaces for external control circuits. Their contact ratings must match the connected load.
| Parameter | Specification |
|---|---|
| Relay channels | 2 |
| Maximum contact voltage | 250 V AC / 120 V DC |
| Maximum continuous current | 2 A RMS |
| Minimum switching current | 5 mA at 24 V DC |
| DC switching capability | 8 A at 24 V DC, resistive load |
| DC switching capability | 0.4 A at 120 V DC, resistive load |
| AC switching capability | 2000 VA at 250 V AC |
| Contact material | Silver cadmium oxide (AgCdO) |
| Contact protection | 250 V varistor |
| Isolation test voltage | 2.5 kV RMS, 1 minute |
Application note: Do not select relay contacts solely by their maximum resistive rating. Motor starting current and inductive energy may require an appropriately rated interposing relay or contactor.
04 | Power Supply, Construction and Environmental Data
| Parameter | Specification |
|---|---|
| Maximum power consumption | 150 mA at 5 V + 30 mA at 24 V |
| Power source | RMIO board |
| Protection rating | IP20 |
| Estimated minimum lifetime | 100,000 hours |
| Net weight | 0.5 kg |
| Net dimensions (W × H × D) | 22.5 × 5.2 × 15.5 cm |
| Mounting | RMIO option slot or AIMA-01 adapter |
| Main bus connection | 38-pin parallel bus connector |
| Field wiring terminals | Four non-detachable screw-type terminal blocks |
| Maximum wire cross-section | 2.5 mm² |
| Material compliance | UL/CSA-approved materials |
| EMC standards | EN 50081-2 and EN 50082-2 |
The module receives both operating voltages from the RMIO board. Check the drive's available power capacity before adding the option.
05 | Hardware Configuration and Drive Integration
The RDIO-01 supports two installation arrangements:
- Direct drive installation: Insert the module into SLOT 1 or SLOT 2 on the RMIO board.
- External I/O installation: Mount the module through an AIMA-01 I/O Module Adapter.
| Configuration Item | Function |
|---|---|
| Rotary switch | Node ID selection, range 1–15 |
| Input DIP switches | Enable or disable hardware filtering for each digital input |
| 38-pin connector | Signal and power connection to the drive |
| Retaining clips | Secure the module in the RMIO option slot |
| Mounting screws | Secure the module and provide I/O cable shield earthing |
The two mounting screws also connect the module GND signals with the RMIO board. Tighten both screws correctly to maintain the intended grounding arrangement.
06 | Installation and Commissioning Procedure
- Isolate the drive from its power source before installation.
- Identify the designated SLOT 1 or SLOT 2 position on the RMIO board.
- Align the module with the 38-pin connector and insert it carefully.
- Press until the retaining clips engage securely.
- Fasten both screws to the mounting stand-offs.
- Remove the module enclosure cover.
- Set the node ID and input-filter DIP switches as required.
- Refit the enclosure cover and inspect the field wiring.
- Restore drive power and observe the diagnostic LEDs.
Check the drive hardware manual for the applicable installation and safety requirements. Confirm terminal assignments before connecting field signals.
07 | Diagnostic LEDs and Fault Isolation
The RDIO-01 uses four diagnostic LEDs to help engineers assess module operation.
| LED | Indication | Engineering Interpretation |
|---|---|---|
| DI1–DI3 | Green, ON | Corresponding input is at logical 1 |
| Status | Yellow, ON during startup | Drive is configuring the module |
| Status remains ON beyond one second | Configuration does not complete | Check installation and communication conditions |
For direct RMIO slot installation:
- Cycle the drive power supply and observe the startup sequence again.
- Check that the 38-pin connector is fully seated.
- If the fault persists, investigate a possible module hardware failure.
- Contact an ABB service representative when necessary.
For AIMA-01 adapter installation:
- Confirm that the drive has power.
- Verify the selected node ID.
- Check fibre-optic transmitter-to-receiver connections.
- Inspect fibre connectors for contamination or incomplete insertion.
- Examine fibre cables for visible damage.
- Reseat the 38-pin connector.
- Substitute known-good fibre cables if communication remains unavailable.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.