Home RDIO-01 ABB ACS800 Digital I/O Extension Module

RDIO-01 ABB ACS800 Digital I/O Extension Module

  • Manufacturer: ABB

  • Product No.: RDIO-01

  • Condition: In stock

  • Product Type: Digital I/O Extension Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

ABB RDIO-01 Digital I/O Extension Module

The ABB RDIO-01 expands the digital signal interface of compatible ABB drives. It provides three digital inputs and two relay outputs for drive status monitoring, external control signals, and relay-based interlocking.

The module accepts both DC and AC input signals. Its inputs support 24–250 V DC or 110–230 V AC, allowing integration with different industrial control circuits. Two relay outputs handle switching duties for external devices and control systems.

Designed for compatible ABB drive platforms, the RDIO-01 digital I/O extension module installs into an RMIO board option slot or an external AIMA-01 I/O Module Adapter. A 38-pin connector establishes the module's signal and power connection.

01 | I/O Architecture at a Glance

Interface Quantity Electrical Capability
Digital inputs 3 24–250 V DC or 110–230 V AC
Relay outputs 2 Up to 250 V AC or 120 V DC
DC input logic — ON above 12 V; OFF below 8 V
AC input logic — ON above 40 V; OFF below 20 V
Input filtering Selectable ON: 5–10 ms; OFF: 2 ms
Input update interval — Minimum 12 ms in ACS800 Standard Application Program
Isolation voltage — 2.5 kV AC; 1.5 kV AC between DI2 and DI3

02 | Digital Input Performance

Three input channels accept industrial AC or DC signals. Their electrical thresholds support reliable state recognition within the specified input range.

Parameter Specification
DC input voltage 24–250 V DC
AC input voltage 110–230 V AC ±10%
DC input current 4–10 mA
AC input current Maximum 4 mA
DC logic 0 Below 8 V
DC logic 1 Above 12 V
AC logic 0 Below 20 V
AC logic 1 Above 40 V
Filter time ON: 5–10 ms; OFF: 2 ms

Each input has a selectable hardware-filter setting. Three green LEDs indicate the individual input states.

Isolation arrangement:

  • DI1 has galvanic isolation from DI2, DI3, relay outputs, and the power supply.
  • DI2 and DI3 form a separate isolation group.
  • DI2 and DI3 also have galvanic isolation from each other.
  • Isolation test voltage: 2.5 kV AC for DI1 and the DI2/DI3 group.
  • Isolation test voltage between DI2 and DI3: 1.5 kV AC.

03 | Relay Output and Contact Specifications

The two relay channels, RO1 and RO2, provide isolated switching interfaces for external control circuits. Their contact ratings must match the connected load.

Parameter Specification
Relay channels 2
Maximum contact voltage 250 V AC / 120 V DC
Maximum continuous current 2 A RMS
Minimum switching current 5 mA at 24 V DC
DC switching capability 8 A at 24 V DC, resistive load
DC switching capability 0.4 A at 120 V DC, resistive load
AC switching capability 2000 VA at 250 V AC
Contact material Silver cadmium oxide (AgCdO)
Contact protection 250 V varistor
Isolation test voltage 2.5 kV RMS, 1 minute

Application note: Do not select relay contacts solely by their maximum resistive rating. Motor starting current and inductive energy may require an appropriately rated interposing relay or contactor.

04 | Power Supply, Construction and Environmental Data

Parameter Specification
Maximum power consumption 150 mA at 5 V + 30 mA at 24 V
Power source RMIO board
Protection rating IP20
Estimated minimum lifetime 100,000 hours
Net weight 0.5 kg
Net dimensions (W × H × D) 22.5 × 5.2 × 15.5 cm
Mounting RMIO option slot or AIMA-01 adapter
Main bus connection 38-pin parallel bus connector
Field wiring terminals Four non-detachable screw-type terminal blocks
Maximum wire cross-section 2.5 mm²
Material compliance UL/CSA-approved materials
EMC standards EN 50081-2 and EN 50082-2

The module receives both operating voltages from the RMIO board. Check the drive's available power capacity before adding the option.

05 | Hardware Configuration and Drive Integration

The RDIO-01 supports two installation arrangements:

  • Direct drive installation: Insert the module into SLOT 1 or SLOT 2 on the RMIO board.
  • External I/O installation: Mount the module through an AIMA-01 I/O Module Adapter.
Configuration Item Function
Rotary switch Node ID selection, range 1–15
Input DIP switches Enable or disable hardware filtering for each digital input
38-pin connector Signal and power connection to the drive
Retaining clips Secure the module in the RMIO option slot
Mounting screws Secure the module and provide I/O cable shield earthing

The two mounting screws also connect the module GND signals with the RMIO board. Tighten both screws correctly to maintain the intended grounding arrangement.

06 | Installation and Commissioning Procedure

  1. Isolate the drive from its power source before installation.
  2. Identify the designated SLOT 1 or SLOT 2 position on the RMIO board.
  3. Align the module with the 38-pin connector and insert it carefully.
  4. Press until the retaining clips engage securely.
  5. Fasten both screws to the mounting stand-offs.
  6. Remove the module enclosure cover.
  7. Set the node ID and input-filter DIP switches as required.
  8. Refit the enclosure cover and inspect the field wiring.
  9. Restore drive power and observe the diagnostic LEDs.

Check the drive hardware manual for the applicable installation and safety requirements. Confirm terminal assignments before connecting field signals.

07 | Diagnostic LEDs and Fault Isolation

The RDIO-01 uses four diagnostic LEDs to help engineers assess module operation.

LED Indication Engineering Interpretation
DI1–DI3 Green, ON Corresponding input is at logical 1
Status Yellow, ON during startup Drive is configuring the module
Status remains ON beyond one second Configuration does not complete Check installation and communication conditions

For direct RMIO slot installation:

  • Cycle the drive power supply and observe the startup sequence again.
  • Check that the 38-pin connector is fully seated.
  • If the fault persists, investigate a possible module hardware failure.
  • Contact an ABB service representative when necessary.

For AIMA-01 adapter installation:

  • Confirm that the drive has power.
  • Verify the selected node ID.
  • Check fibre-optic transmitter-to-receiver connections.
  • Inspect fibre connectors for contamination or incomplete insertion.
  • Examine fibre cables for visible damage.
  • Reseat the 38-pin connector.
  • Substitute known-good fibre cables if communication remains unavailable.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.