Home P-LB-2.B.1245 2-Channel Lightning Protection Barrier Pepperl+Fuchs

P-LB-2.B.1245 2-Channel Lightning Protection Barrier Pepperl+Fuchs

  • Manufacturer: Pepperl+Fuchs

  • Product No.: P-LB-2.B.1245

  • Condition: In stock

  • Product Type: Surge Protection Barrier

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Engineering Architecture & System Purpose

The Pepperl+Fuchs P-LB-2.B.1245 is a specialized 2-channel surge and lightning protection barrier engineered specifically for seamless plug-in integration with the K-System (KF module) infrastructure. Designed to safeguard sensitive analog and digital instrumentation loops against severe transient overvoltages, the P-LB-2.B.1245 intercepts high-energy surges up to 10 kA while preserving uninterrupted signal transmission in hazardous process control environments.

Technical Parameter Matrix

Manufacturer & Series Pepperl+Fuchs K-System (Light-Barrier / P-LB)
Exact Part Number P-LB-2.B.1245 (Item No. 103640)
Channel Configuration 2-Channel direct loop protection (protects leads 1, 2, 4, and 5 of KF modules)
Electrical Ratings 30 V working voltage, 250 mA maximum current, 40 kHz frequency bandwidth
Surge & Clamping Limits 10 kA Peak Surge capability; 45 V on-state / 500 V line-to-ground clamping voltage
Transient Response Speed 1 ns symmetric response / 100 ns asymmetric response
Leakage & Reset Characteristics 5 µA short-circuit current rating; fully automatic, uninterruptible reset mechanism
Environmental & Housing Specs Operating temperature -4°F to 140°F (-20°C to 60°C); IP20 enclosure; dimensions 0.8 x 2.4 x 4.5 in
Hazardous Area & Safety Compliance SIL 3 functional safety; IECEx BAS 12.0123; [Ex ia Ga] IIC / [Ex ia Da] IIIC / [Ex ia Ma] I; CE Certified

Mechanical Installation & Integration Protocol

  • Direct Module Docking: The P-LB-2.B.1245 clicks directly into the field side of compatible K-System (KF) base modules without requiring extra DIN rail space or custom wiring harnesses.
  • Terminal Lead Protection: Precision-engineered internal circuitry simultaneously clamps transient spikes across terminals 1, 2, 4, and 5, shielding downstream isolated barriers and PLC analog input cards.
  • Automatic Reset Operation: Following a high-energy transient discharge, the internal solid-state components instantly recover without operator intervention or blown fuse replacements.

Instrumentation Commissioning & Loop Verification

  • Signal Transparency Check: Verify that the 40 kHz frequency bandwidth does not attenuate high-speed pulse or HART-modulated diagnostic signals traveling through the loop.
  • Grounding Continuity: Ensure the mounting rail and internal ground paths are tied to low-impedance earth ground to allow the 500 V line-to-ground clamping circuit to safely shunt high-energy lightning transients.

System Compatibility & Hazardous Area Deployment

  • Explosive Atmosphere Ratings: Fully certified for installation in IECEx Zone 1 and Zone 2 hazardous areas, as well as Class I, Division 1 and Division 2 environments under intrinsic safety guidelines.
  • Functional Safety Integration: Certified up to SIL 3, making it ideal for safety-instrumented systems (SIS) where reliable overvoltage protection is mission-critical.

Package Contents & Logistics Overview

  • Factory Condition: Supplied brand new in original Pepperl+Fuchs factory packaging with technical data sheet.
  • Included Hardware: One P-LB-2.B.1245 surge protection module with integrated plug-in terminal connections.

Engineering Field Guide & Selection FAQ

Q: How does plugging this barrier into the KF module field side affect existing loop wiring?

A: The module acts as an inline pass-through adapter. Field wires land directly on the protection barrier terminals, eliminating the need to redesign or rewire existing marshalling cabinets.

Q: Will the 40 kHz bandwidth interfere with HART communication protocols on 4-20 mA loops?

A: No. HART frequency shift keying (FSK) signals operate well below the 40 kHz threshold (typically around 1.2 to 2.2 kHz), ensuring transparent digital communication overlay.

Q: What maintenance is required after the barrier absorbs a lightning-induced 10 kA peak surge?

A: None. The unit features an automatic reset design. Once the transient voltage clears, it returns to normal operation without requiring manual fuse changes or component swaps.

Q: Why is line-to-ground clamping rated at 500 V while working voltage is 30 V?

A: The 500 V threshold represents the dynamic breakdown voltage required to safely divert massive high-frequency electrostatic discharges and lightning strikes safely to earth ground without false tripping during normal operation.

Q: Can this surge protector be installed in Zone 0 or intrinsically safe loops?

A: While the module carries IECEx intrinsic safety ratings ([Ex ia Ga] IIC), it is designed for installation in safe areas or Zone 2/Division 2 while protecting field circuits running into Zone 0/1 hazardous areas.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.