P-LB-2.A.1346 Pepperl+Fuchs P-LB Series 2-Channel Surge Protection Barrier
Manufacturer: Pepperl+Fuchs
Product No.: P-LB-2.A.1346
Condition: In stock
Product Type: Surge Protection Barrier
Product Origin: USA
Payment: T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Engineering Architecture & System Integration
Instrumentation engineers deploy the P-LB-2.A.1346 Pepperl+Fuchs P-LB Series 2-channel surge protection barrier to safeguard sensitive control system inputs against transient lightning strikes and heavy inductive switching surges. Designed for seamless plug-in mounting directly onto the field side of KF modules, this compact barrier intercepts surges up to 10 kA per conductor on leads 1, 3, 4, and 6 without introducing signal degradation. Its automatic reset mechanism guarantees uninterruptible loop operation across critical process automation loops.
| Functional Domain | Engineering Parameter | Technical Specification |
|---|---|---|
| Identification | Brand, Model & Part Number | Pepperl+Fuchs P-LB-2.A.1346 (P-LB-2.A1346 / 103638) |
| Architecture | Product Series & Type | P-LB Series 2-Channel Surge Protection Barrier |
| Electrical | Voltage & Current Ratings | Max 30 V DC rated voltage; Max 250 mA operating current |
| Protection | Surge Capacity & Leakage | 10 kA per conductor peak pulse; Max 5 µA leakage current |
| Mechanical | Physical Dimensions & Mass | 20 × 104 × 127 mm modular housing; Approx. 70 g net weight |
| Environment | Thermal Range & Ingress | -20 °C to +60 °C ambient operating span; IP20 enclosure rating |
| Safety | Functional & Hazardous Approvals | SIL 3 per IEC/EN 61508; ATEX / IECEx certified (Ex ia/nA) |
Technical Implementation & Operational Features
- Direct Plug-in Topology: Eliminates external DIN-rail terminal blocks by mounting directly onto standard K-System (KF) barrier housings, preserving precious control cabinet footprint.
- Uninterrupted Signal Loop: Features automatic self-resetting surge diversion networks that recover instantly after transient suppression without requiring manual fuse replacement.
- Dual-Channel Versatility: Handles both analog 4-20 mA control loops and digital discrete input/output signals with ultra-low series resistance.
- Explosion Protection Compliance: Certified for intrinsic safety (Ex ia) and non-sparking (Ex nA) installations within Zone 2 hazardous process environments.
Advanced Field Engineering FAQ
Q1: How does plugging the P-LB-2.A.1346 barrier onto a KF module affect loop resistance and transmitter calibration?
A1: The internal protective components add minimal series resistance to the circuit. For standard 4-20 mA loops, this voltage drop is negligible and does not require recalibrating field transmitters or DCS analog input cards.
Q2: Can I use this barrier in safety-instrumented functions requiring SIL certification?
A2: Yes, the unit is independently certified to SIL 3 per IEC/EN 61508, making it fully compatible with safety instrumented systems (SIS) in emergency shutdown (ESD) applications.
Q3: What maintenance checks should instrument technicians perform on these barriers after a severe electrical storm?
A3: Measure the leakage current across the terminals. If leakage exceeds the 5 µA threshold or if the internal diagnostic monitoring indicates a degraded suppression stage, replace the plug-in module immediately.
Q4: Why does the unit have an IP20 rating if it is installed in harsh industrial cabinets?
A4: An IP20 rating assumes the module resides inside a sealed, weather-proof control panel or cabinet. The cabinet protects against dust and moisture, while the IP20 housing prevents accidental finger contact with live terminals.
Q5: How do I verify that the grounding path for the surge barrier is properly established?
A5: Ensure the base K-System mounting rail is bonded to a low-impedance copper ground busbar. The surge current collected by the P-LB-2.A.1346 discharges directly through the DIN rail mounting foot into the cabinet ground.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.