Home KFD0-SD2-EX1.1045 Pepperl+Fuchs Solenoid Driver | K-System Safety Barrier

KFD0-SD2-EX1.1045 Pepperl+Fuchs Solenoid Driver | K-System Safety Barrier

  • Manufacturer: Pepperl+Fuchs

  • Product No.: KFD0-SD2-EX1.1045

  • Condition: In stock

  • Product Type: Solenoid Driver

  • Product Origin: DE

  • Payment: T/T, Western Union

  • Weight: 150g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

01 | Product Identity & Operating Principle

The KFD0-SD2-EX1.1045 is a single-channel solenoid driver from Pepperl+Fuchs. It belongs to the K-System isolated barrier family.

This module transfers digital output signals from control equipment to hazardous-area field devices. It provides an intrinsically safe output for compatible solenoid valves and other suitable loads.

The device uses a loop-powered architecture. It operates with a 20–35 V DC control-side supply. Its output limits current to 45 mA while maintaining at least 10 V DC under specified operating conditions.

Its compact B1 housing supports DIN rail installation. LED indication helps technicians identify operating conditions. Reinforced application design supports functional safety requirements up to SIL 3.

02 | Core Technical Data

Manufacturer Pepperl+Fuchs
Model KFD0-SD2-EX1.1045
Product Series K-System
Product Type Solenoid Driver / Isolated Barrier
Signal Classification Digital Output
Channel Count 1 Channel
Power Architecture Loop Powered
Supply Voltage 20–35 V DC
Maximum Output Current 45 mA
Minimum Output Voltage 10 V DC
Maximum Internal Resistance 282 Ω
Functional Safety SIL 3
Hazardous Area Protection Intrinsic Safety Ex ia
Mounting 35 mm DIN Rail
Protection Rating IP20

03 | Electrical Performance & Output Characteristics

Control-Side Input

Connection Terminals 7, 8
Rated Input Voltage 20–35 V DC
Input Current at 20 V 72 mA with 220 Ω load
Input Current at 35 V 50 mA with 220 Ω load
Inrush Current ≤ 200 mA after 100 µs
Power Dissipation < 1.05 W at ≤ 30 V

Field-Side Output

Connection Terminals 1+, 2-
Maximum Internal Resistance 282 Ω
Output Current ≤ 45 mA
Minimum Output Voltage ≥ 10 V
Minimum Open-Loop Voltage 22.7 V
Rated Operating Current 45 mA

Switching Response

Single Operation Energized Delay Typical 1.7 ms
Single Operation De-energized Delay 50 µs
Periodic Operation Energized Delay Typical 5 µs
Periodic Operation De-energized Delay 50 µs

These electrical values apply within the specified 20–35 V DC operating range. Check the actual field load before selecting the driver.

04 | Intrinsic Safety & Hazardous Area Parameters

The KFD0-SD2-EX1.1045 provides an intrinsically safe field interface. Its certified output parameters help engineers evaluate compatible hazardous-area loads.

EU-Type Examination Certificate BASEEFA 06 ATEX 0252
Additional Certificate TÜV 99 ATEX 1499 X
Gas Classification II (1)G [Ex ia Ga] IIC
Dust Classification II (1)D [Ex ia Da] IIIC
Mining Classification I (M1) [Ex ia Ma] I
Output Voltage Uo 25.2 V
Output Current Io 93 mA
Output Power Po 590 mW
Maximum Safe Input Voltage Um 250 V
Input/Output Isolation 375 V peak value
Isolation Standard IEC/EN 60079-11

Additional Ex nA Marking

  • Certificate: TÜV 99 ATEX 1499 X.
  • Classification: II 3G Ex nA II T4.

Important Engineering Note: Uo, Io, and Po are safety assessment parameters. They are not normal operating output values. Verify the complete intrinsic safety loop, including cable capacitance, inductance, and field-device ratings.

05 | International Approvals & Compliance

ATEX Certificate BASEEFA 06 ATEX 0252
Additional ATEX Certificate TÜV 99 ATEX 1499 X
IECEx Certificate IECEx BAS 06.0058
IECEx Certificate IECEx CML 19.0093X
FM Approval Control Drawing 116-0309
UL Approval E106378
cULus Control Drawing 116-0316
EMC Directive 2014/30/EU
EMC Standard EN 61326-1:2013
EMC Recommendation NE 21:2006
Electrical Shock Protection UL 61010-1:2004
Ingress Protection Standard IEC 60529:2001
ATEX Directive 2014/34/EU
Explosion Protection Standards EN IEC 60079-0:2018+AC:2020, EN 60079-11:2012, EN 60079-15:2010

06 | Mechanical Design & Environmental Limits

Housing Type B1
Dimensions (W × H × D) 20 × 107 × 115 mm
Weight Approximately 100 g
Operating Temperature -20 to +60 °C (-4 to +140 °F)
Protection Rating IP20
Electrical Connection Screw Terminals
Mounting Method 35 mm DIN Rail
Mounting Standard EN 60715:2001
Status Display LED
Front Labeling Labeling Space Available

07 | Application Scenarios & Control Functions

  • Solenoid Valve Control: Drives compatible intrinsically safe solenoid loads from control-side digital outputs.
  • Process Shutdown Systems: Supports suitable safety-related output circuits in process installations.
  • Hazardous Area Equipment: Interfaces field devices in certified gas, dust, and mining environments.
  • Industrial Valve Automation: Controls compatible pneumatic valve actuators through solenoid interfaces.
  • PLC Digital Outputs: Connects control-system output channels to suitable field-side loads.
  • Safety Instrumented Systems: Supports SIL 3 applications when the complete safety loop meets required conditions.

08 | Wiring & Commissioning Reference

Terminal Assignment

Terminal Connection Side Function
7, 8 Control Side Digital control input
1+, 2- Field Side Intrinsically safe output

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.