KFD0-CS-Ex2.50P Pepperl+Fuchs K-System Loop-Powered Ex Barrier Module
Manufacturer: Pepperl+Fuchs
Product No.: KFD0-CS-Ex2.50P
Condition: In stock
Product Type: Isolated Barrier Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview & Architecture
The Pepperl+Fuchs KFD0-CS-Ex2.50P functions as a high-density, 2-channel isolated barrier engineered specifically for hazardous location loops. This loop-powered unit eliminates the need for an external auxiliary power supply, drawing operational energy directly from the 4 mA to 20 mA current loop. Instrumentation engineers deploy the KFD0-CS-Ex2.50P module to drive 2-wire transmitters or operate as an isolated signal repeater while providing galvanic isolation between hazardous field instruments and safe-area control systems.
Engineering Specifications & Performance Metrics
| Manufacturer | Pepperl+Fuchs |
| Model & Series | KFD0-CS-Ex2.50P / K-System Isolated Barriers |
| Channel Configuration | Dual-channel (2-channel) isolated analog interface |
| Input / Output Signal Range | 4 mA to 20 mA analog current loop |
| Loop Voltage Range (Uin) | 5 V DC to 35 V DC control circuit input |
| Transfer Accuracy | ±0.1% including calibration, linearity, hysteresis, and load shifts up to 1 kΩ |
| Temperature Drift Coefficient | ≤ ±2 µA/K (at Uin ≤ 20 V); ≤ ±5 µA/K (at Uin > 20 V) |
| Signal Rise Time | ≤ 5 ms (for step changes from 4 to 20 mA at Uin < 24 V) |
| Power Dissipation | < 250 mW per channel (at 20 mA, Uin < 24.3 V); < 500 mW (at Uin > 24.3 V) |
| Galvanic Isolation Rating | Safe electrical isolation up to 375 V peak value per IEC/EN 60079-11 |
Operational Safety & Hazardous Area Approvals
- Functional Safety: Certified up to SIL 2 (SC 3) performance level compliant with IEC/EN 61508.
- EU-Type Examination: BAS 98 ATEX 7343 and TÜV 99 ATEX 1499 X certifications.
- Ex Classification: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; Zone 2 non-sparking (Ex nA II T4) compliance.
- Entity Parameters: Maximum output voltage Uo = 25.2 V, short-circuit current Io = 93 mA, output power Po = 585 mW.
Mechanical Properties & Installation Parameters
- Enclosure Dimensions: Compact profile measuring 20 mm x 107 mm x 115 mm (Housing Type B1).
- Mounting Standard: Snaps securely onto standard 35 mm DIN mounting rails (EN 60715:2001).
- Ingress Protection: IP20 rated housing with captive screw terminals for secure wire retention.
- Operating Threshold: Designed for ambient temperatures spanning -20 °C to 60 °C (-4 °F to 140 °F).
- Weight Profile: Lightweight structural design weighing approximately 100 grams.
Frequently Asked Questions (FAQ)
Q: Can the KFD0-CS-Ex2.50P supply enough voltage to power a standard 2-wire HART transmitter?
A: Yes, provided the control system loop voltage meets the minimum terminal requirements. The field circuit terminal voltage scales dynamically based on input voltage and current draw, but designers should verify that the remaining voltage across the transmitter terminals exceeds its minimum operating threshold (typically 12V to 15V).
Q: How does loop-powered operation affect the maximum load resistance on the control side?
A: Because the device derives its operational energy directly from the 4-20mA loop, the connected control system input impedance (load resistor) must be factored into the total loop voltage drop. Excessive load resistance will starve the barrier of the required 5V minimum operating voltage across terminals 11 and 12.
Q: What causes measurement errors to drift beyond the specified 0.1% accuracy during field testing?
A: Thermal fluctuations outside the nominal calibration range account for most drift. When loop voltage exceeds 20 V DC, the temperature coefficient increases to ±5 µA/K, which can introduce minor offsets if control cabinets experience severe internal temperature swings.
Q: Is it permissible to use only one channel while leaving the second channel unconnected in safety loops?
A: Yes, unassigned channels on the KFD0-CS-Ex2.50P can remain completely open without affecting the operational stability or safety rating of the active channel, though proper wire termination rules for unused hazardous area terminals must be observed.
Q: What maintenance checks should technicians perform during routine plant shutdowns?
A: Technicians should inspect DIN rail physical security, check screw terminal torque to prevent high-resistance contact points, and verify that the galvanic isolation barriers remain free from conductive dust accumulation inside the IP20 cabinet enclosure.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.