KFA5-SR2-EX1.W Pepperl+Fuchs NAMUR Relay Isolator
Manufacturer: Pepperl+Fuchs
Product No.: KFA5-SR2-EX1.W
Condition: In stock
Product Type: Relay Isolator
Product Origin: DE
Payment: T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview
The Pepperl+Fuchs KFA5-SR2-EX1.W is a single-channel isolated switch amplifier for industrial automation and hazardous-area applications.
It receives signals from dry contacts or NAMUR sensors. The module transfers switching signals through a relay contact output. Its galvanic isolation separates the field input, control output, and power supply.
The unit supports Line Fault Detection (LFD) and reversible operating modes. It also supports safety-related applications up to SIL 2, according to IEC/EN 61508 and IEC/EN 61511.
Its compact housing supports 35 mm DIN rail installation. Front LEDs provide operating status information. DIP switches allow direct configuration.
Technical Specifications
| Brand | Pepperl+Fuchs |
| Model | KFA5-SR2-EX1.W |
| Product Series | K-System |
| Product Type | Switch Amplifier / Isolated Barrier |
| Signal Type | Digital Input |
| Channel Configuration | 1-channel |
| Functional Safety | SIL 2 |
| Input Compatibility | Dry Contact / NAMUR Sensor |
| Output Type | Relay Contact |
| Operating Mode | Reversible |
| Line Fault Detection | Supported |
| Mounting | 35 mm DIN Rail |
| Protection Rating | IP20 |
Electrical and Signal Specifications
| Power Supply | |
| Supply Terminals | 14, 15 |
| Rated Supply Voltage | 103.5–126 V AC |
| Supply Frequency | 45–65 Hz |
| Power Consumption | 1 W |
| Input Characteristics | |
| Input Terminals | 1+, 2+, 3- |
| Input Standard | EN 60947-5-6 (NAMUR) |
| Open-Circuit Voltage | Approximately 8 V DC |
| Short-Circuit Current | Approximately 8 mA |
| Switching Threshold | 1.2–2.1 mA |
| Switching Hysteresis | Approximately 0.2 mA |
| Line Break Detection | Current ≤ 0.1 mA |
| Short-Circuit Detection | Current > 6 mA |
| Minimum Pulse Duration | 20 ms |
| Minimum Pause Duration | 20 ms |
| Relay Output Characteristics | |
| Output Terminals | 7, 8, 9 |
| Output Signal | Relay Contact |
| Contact Rating | 253 V AC / 2 A, cos φ > 0.7 |
| Alternative AC Rating | 126.5 V AC / 4 A, cos φ > 0.7 |
| DC Contact Rating | 40 V DC / 2 A, resistive load |
| Energized Delay | Approximately 20 ms |
| De-energized Delay | Approximately 20 ms |
| Mechanical Life | 10⁷ switching cycles |
| Maximum Switching Frequency | Less than 10 Hz |
Galvanic Isolation and Safety Parameters
- Input-to-Output: Reinforced insulation according to IEC/EN 61010-1.
- Input-to-Power Supply: Reinforced insulation according to IEC/EN 61010-1.
- Output-to-Power Supply: Reinforced insulation according to IEC/EN 61010-1.
- Rated Insulation Voltage: 300 V RMS for each isolation path.
- Safety Integrity Level: SIL 2.
- Safety Standards: IEC/EN 61508 and IEC/EN 61511.
The isolated architecture reduces electrical interaction between field devices and control equipment. It supports reliable signal transmission in industrial control systems.
Hazardous Area Application Data
| EU-Type Examination Certificate | PTB 00 ATEX 2081 |
| Input Protection Type | Ex ia |
| Gas Marking | II (1)G [Ex ia Ga] IIC |
| Dust Marking | II (1)D [Ex ia Da] IIIC |
| Mining Marking | I (M1) [Ex ia Ma] I |
| Output Voltage Uo | 10.6 V |
| Output Current Io | 19.1 mA |
| Output Power Po | 51 mW |
| Output Characteristic | Linear |
| Maximum Safe Supply Voltage Um | 126.5 V AC |
| Maximum Safe Output Voltage Um | 253 V AC |
Important: Um represents the maximum safe voltage. It does not represent the normal rated operating voltage.
Environmental and Mechanical Specifications
| Operating Temperature | -20 to +60 °C (-4 to +140 °F) |
| Protection Rating | IP20 |
| Connection Type | Screw Terminals |
| Housing Type | B2 |
| Dimensions (W × H × D) | 20 × 119 × 115 mm |
| Weight | Approximately 150 g |
| Mounting Method | 35 mm DIN Rail, EN 60715 |
| Configuration | DIP Switches |
| Status Indicators | LEDs |
| Front Labeling | Available |

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.