Honeywell C7061F1003 Purple Peeper UV Flame Scanner & Detector
Manufacturer: Honeywell
Product No.: C7061F1003
Condition: In stock
Product Type: UV Flame Scanner
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Honeywell C7061F1003 Product Overview
The **C7061F1003** unit operates as an advanced ultraviolet flame detector. Engineers design this device specifically for heavy industrial combustion applications. It detects ultraviolet radiation emitted by gas and oil burner flames. The dynamic self-checking mechanism verifies detector operation continuously. Operators rely on this sensor for reliable burner management systems.
Technical Specifications
Engineers classify technical parameters into distinct operational categories for precise system integration:
| Parameter Category | Technical Specification |
|---|---|
| Brand & Model | **Honeywell** **C7061F1003** (**C7061F** Series) |
| Sensing Spectrum | Ultraviolet (UV) radiation matching -40 F rated sensing tube |
| Electrical Ratings | 120 Vac or 230 Vac input voltage |
| Operating Frequency | 50 Hz and 60 Hz support |
| Ambient Temperature Range | -40 F to +175 F (-40 C to +79 C) |
| Environmental Tolerance | Explosion-proof housing for hazardous atmospheres; viewing window rated to 100 psi |
| Anti-Interference Capability | Dynamic self-checking rejects spurious signals and background radiation |
| Sensitivity & Resolution | High-sensitivity UV tube detects low-intensity pilot flames accurately |
Installation Guidelines
- Technicians mount the unit using standard 1-inch NPT or 3/4-inch mounting configurations.
- Ensure correct thread engagement to maintain explosion-proof pressure ratings.
- Route the 96-inch color-coded lead wires away from high-voltage ignition cables.
- Verify proper alignment with the burner flame envelope during initial mechanical setup.
- Connect the unit strictly according to wiring diagrams supplied with compatible flame amplifiers.
Commissioning & Maintenance Convenience
- Built-in protective heat block shields internal optics from extreme burner temperatures.
- Self-checking shutter mechanism tests detector integrity automatically without manual interruption.
- Clear viewing window allows quick visual inspection and cleaning access.
- Parallel wiring option supports dual detectors in difficult sighting applications to prevent nuisance shutdowns.
Compatibility Information
- Engineers pair the **C7061F1003** directly with **R7861** Flame Amplifiers.
- The sensor integrates seamlessly into industrial burner management and safeguarding control loops.
- Matches gas-fired and oil-fired combustion burner systems seamlessly.
Certification Information
- Explosion-proof housing design meets strict safety standards for hazardous industrial locations.
- Meets rigorous industrial compliance for flame safety monitoring equipment.
Package List
- One **Honeywell C7061F1003** UV Flame Detector unit
- 96-inch factory color-coded lead wires
- Integrated mounting flange with protective heat block
- Explosion-proof viewing window assembly
Buying Guide
Plant engineers choose the **C7061F** series when operating in hazardous explosive atmospheres requiring robust 100 psi window ratings. Match your system voltage (120Vac or 230Vac) and amplifier type (**R7861**) prior to purchase. Contact our engineering sales team for custom application support or bulk inquiries.
Frequently Asked Questions
Question: Can technicians wire two detectors together in complex applications?
Answer: Yes. Technicians wire two detectors in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Question: What pressure rating does the explosion-proof viewing window support?
Answer: The viewing window withstands pressures up to 100 psi safely.
Question: Which flame amplifier works with this sensor?
Answer: This detector pairs directly with **R7861** flame amplifiers.
Question: How does the dynamic self-checking feature function?
Answer: A mechanical shutter periodically tests the detector circuit to verify proper ultraviolet sensing capability.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.