Honeywell 05701-A-0325 24VDC Rack Power Input Module
Manufacturer: Honeywell
Product No.: 05701-A-0325
Condition: In stock
Product Type: Input Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 250g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Introduction
The Honeywell 05701-A-0325 is a DC Input Card designed for the Honeywell System 57 gas detection platform. It provides the primary 24VDC power connection for the system sub-rack. The card accepts an external nominal 24VDC supply and distributes power through the Engineering Card and backplane. This arrangement supplies the operating voltage required by compatible rack modules. The integrated fuse protects the incoming DC supply circuit. RFI filtering helps reduce electrical interference from the power input. Reverse polarity protection adds another layer of protection against incorrect supply connections. The card also supports an auxiliary DC connection for a standby backup battery. Isolation diodes separate the main PSU input from the auxiliary supply. This arrangement supports backup power integration without directly connecting both supply circuits. A two-part terminal block, designated TB1, simplifies field wiring. Technicians can remove the card without disconnecting every individual wire.
Technical Specifications
| Parameter | Description |
| Brand | Honeywell |
| Model | 05701-A-0325 |
| Product Type | DC Input Card |
| Product Series | System 57 |
| Primary Input | Nominal 24VDC |
| Power Distribution | Engineering Card and sub-rack backplane |
| Input Protection | Integrated fuse |
| Polarity Protection | Reverse polarity protection |
| EMC Protection | RFI filtering |
| Auxiliary Input | Standby backup battery connection |
| Supply Isolation | Diode isolation between PSU and AUX connections |
| Wiring Interface | Two-part terminal block TB1 |
| Compatible Platform | Honeywell System 57 |
Power Supply Architecture and System Integration
The 05701-A-0325 distributes incoming DC power through the System 57 sub-rack. Its power architecture includes three main functions:
- Primary power input: Accepts an external nominal 24VDC supply.
- Rack power distribution: Routes DC power through the Engineering Card and backplane.
- Auxiliary power input: Supports a separate standby battery connection.
The PSU and AUX inputs use isolation diodes. This arrangement separates the two supply paths electrically. For installations with more than eight 5704 Catalytic Cards, Honeywell recommends a specific power arrangement. In this configuration:
- Power the Control Cards through their associated Quad Relay Interface Cards.
- Use the 05701-A-0325 to power the Engineering Card only.
- Follow the rack wiring documentation when distributing the remaining loads.
This arrangement helps prevent excessive current flow through the rack backplane.
Compatible AC/DC Power Supply Units
Honeywell specifies two rack-mounted AC-to-DC power supply units for System 57 installations.
| Power Supply Model | 05701-A-0406 | 05701-A-0405 |
| Configuration | 8-way supply unit | 16-way supply unit |
| Rack Format | 1U, half-width, 19-inch rack mounting | 1U, 19-inch rack mounting |
| Power Module | Single 50W switched-mode module | Single 50W switched-mode module |
| AC Input | 85–264VAC | 85–264VAC |
| AC Frequency | 47–440Hz | 47–440Hz |
| DC Input | 110–340VDC | 110–340VDC |
These units provide the AC-to-DC conversion required by compatible System 57 installations. Confirm the supply configuration before selecting a replacement or additional power unit.
Installation Guidelines
Correct installation helps maintain stable power distribution across the System 57 rack.
- Verify the card model against the rack configuration before installation.
- Confirm the external supply provides nominal 24VDC.
- Isolate the rack power before handling electrical connections.
- Check the TB1 terminal assignments against the official wiring diagram.
- Connect the primary PSU input with correct polarity.
- Connect the auxiliary battery supply only when the application requires it.
- Inspect the backplane connector for contamination or physical damage.
- Secure the card correctly within its designated rack position.
For racks containing more than eight 5704 Catalytic Cards, follow Honeywell's recommended power distribution arrangement.
Commissioning and Maintenance
Commissioning should verify both the incoming supply and rack power distribution.
- Input voltage: Measure the incoming DC supply before energizing the rack.
- Polarity: Verify positive and negative connections at TB1.
- Fuse inspection: Check the input fuse if the rack receives no power.
- Auxiliary supply: Verify backup battery connections when installed.
- Backplane inspection: Check connector seating and signs of overheating.
- Interference: Investigate unstable operation when electrical noise affects the installation.
- Load distribution: Review backplane loading when expanding the detector configuration.
The removable two-part TB1 terminal block simplifies maintenance. Technicians can remove the card without individually disconnecting all field wires. Always isolate the power source before replacing the card or inspecting its connections.
Compatibility and Selection Considerations
The 05701-A-0325 serves as a DC power input interface within the Honeywell System 57 platform. It is not a general-purpose DC input signal acquisition module. Before purchasing, verify the following:
- System compatibility: Confirm that the existing sub-rack supports this System 57 card.
- Voltage requirements: Check the nominal 24VDC rack supply specification.
- Power configuration: Review the number and types of installed rack modules.
- Backup requirements: Determine whether the installation needs an auxiliary battery connection.
- Rack loading: Check the recommended arrangement for installations exceeding eight 5704 Catalytic Cards.
- Power supply selection: Confirm whether the 05701-A-0405 or 05701-A-0406 suits the rack configuration.
Do not select this card based only on its 24VDC rating. Verify the complete rack architecture and electrical connections.
Engineering Advantages
- Centralized power distribution: Routes incoming DC power through the rack backplane.
- Input circuit protection: Combines fuse protection and reverse polarity protection.
- Electrical interference control: Includes RFI filtering at the power input.
- Backup supply support: Provides auxiliary DC input connections.
- Supply separation: Uses diodes to isolate PSU and AUX connections.
- Maintenance efficiency: Features a removable two-part TB1 terminal block.
Package Contents
- 1 × Honeywell 05701-A-0325 DC Input Card
- Product identification and packing documentation, where supplied
FAQ
Q1: What is the primary function of the Honeywell 05701-A-0325?
The card accepts nominal 24VDC power and distributes it throughout the System 57 sub-rack. It also provides input protection and auxiliary power connections.
Q2: Can the 05701-A-0325 power all Control Cards directly?
Not in every rack configuration. Honeywell recommends powering Control Cards through their associated Quad Relay Interface Cards when installations contain more than eight 5704 Catalytic Cards. The DC Input Card should then power the Engineering Card only.
Q3: What should engineers check when the System 57 rack does not power up?
Start by measuring the incoming 24VDC supply. Next, inspect the TB1 wiring, input fuse, card seating, and backplane connections. Also check the auxiliary supply arrangement when backup power is installed.
Q4: Can technicians remove the card without disconnecting every wire?
Yes. The two-part TB1 terminal block supports convenient card removal. Follow the correct isolation procedure before removing the card.
Q5: How should buyers select the correct System 57 power configuration?
Check the rack size, installed detector cards, total power demand, and backup battery requirements. Also verify compatibility with the 05701-A-0405 or 05701-A-0406 power supply unit. Consult the rack wiring documentation before ordering.
Q6: Does the 05701-A-0325 provide RFI and reverse polarity protection?
Yes. The card incorporates RFI filtering and reverse polarity protection. These features help protect the DC input circuit against electrical interference and incorrect supply connections.
Q7: Does Honeywell specify operating temperature or environmental ratings for this card?
The available product information does not specify operating temperature, humidity, or enclosure protection ratings. Check the official System 57 technical documentation before applying the card in demanding environments.
Ordering and Technical Support
The Honeywell 05701-A-0325 System 57 DC Input Card supports reliable power distribution in industrial gas detection systems. Contact our team to confirm model compatibility, rack configuration, and current availability. We provide technical assistance for industrial automation spare parts and replacement selection.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.