System Architecture & Fluidic Design

The FC-R7800 represents a robust benchmark in metal-sealed analog mass flow control from AERA. Built within the proven FC-R7800 Series, this instrument governs inert and aggressive corrosive gases across demanding semiconductor processes, including etch, CVD, PVD, diffusion, and ion implantation. Engineers select this platform for its ultra-high leak integrity, predictable solenoid valve dynamics, and drop-in mechanical compatibility with legacy gas sticks.

Core Metrological & Physical Data

  • Manufacturer & Family: AERA — FC-R7800 Series (Analog, Metal-Sealed)
  • Model Designation: FC-R7800
  • Flow Span & Turndown: 10 sccm to 5 slm full-scale range; 2% to 100% FS control turndown
  • Accuracy & Linearity: ≤ ±1% FS accuracy; ≤ ±0.5% FS linearity
  • Repeatability & Drift: ≤ ±0.2% FS repeatability; < 0.5% FS annual zero stability
  • Dynamic Settling Time: < 1 second to within ±2% FS between command setpoints
  • Pressure Envelope: 7 to 40 psiD differential; 70 psig normal operating; 140 psig max inlet
  • Wetted Construction: Type 316(L) and 316 stainless steel, magnetic stainless, and PTFE
  • Sealing & Leak Rate: All-metal 316L seals; ≤ 1 × 10-10 atm-cc/sec (He) / 1 × 10-11 Pa·m3/sec (He)
  • Electrical I/O & Power: 0 to 5 VDC analog command/output via Aera 9-pin D-sub; +15 VDC (25 mA) and -15 VDC (180 mA), 3.1 W max
  • Thermal & Mechanical Profile: Unheated (5°C to 45°C ambient); 132 × 28.6 × 183.8 mm (183.8 mm port-to-port with 1/4" VCR); 1.0 kg (2.2 lb)
  • Actuation & Compliance: Solenoid control valve (Normally-Open or Normally-Closed); RoHS compliant

Mechanical & Pneumatic Integration

  1. Inspect the 1/4" VCR male glands and install fresh 316L metal gaskets using cleanroom-approved torque wrenches to preserve the 10-10 atm-cc/sec leak specification.
  2. Verify manifold spacing accommodates the 183.8 mm port-to-port footprint and 28.6 mm slim body width.
  3. Regulate supply lines to sustain a differential pressure strictly within the 7 to 40 psiD operating window across the solenoid orifice.
  4. Mate the Aera 9-pin D-sub connector and confirm ±15 VDC rail stability prior to introducing process gas.

Field Calibration & Operational Readiness

  • Allow the thermal sensor bypass tube to stabilize within the 5°C to 45°C ambient envelope before executing zero-point adjustments.
  • Monitor the 0 to 5 VDC analog feedback signal during ramp-up to confirm sub-second settling behavior across process recipe steps.
  • Purge reactive or corrosive lines thoroughly with dry nitrogen before disconnecting fittings during preventative maintenance cycles.

Legacy Drop-In Compatibility

Designed with industry-standard 183.8 mm port-to-port dimensions and a classic Aera 9-pin D-sub interface, the FC-R7800 integrates directly into existing analog gas panels without manifold rework or PLC analog card modifications.

Included Shipment Items

  • One FC-R7800 Metal-Sealed Mass Flow Controller
  • Protective VCR Port Caps (Installed)
  • Factory Calibration Data Sheet & RoHS Declaration

Engineering Selection Checklist

  • Specify your exact target gas species and full-scale flow rate (between 10 sccm and 5 slm) when submitting an inquiry.
  • Confirm safety interlock requirements to choose between Normally-Closed (NC) and Normally-Open (NO) solenoid valve configurations.
  • Check power supply current headroom on the -15 VDC rail (180 mA draw per unit) when populating multi-channel gas boxes.

Technical Engineering FAQ

Q: How does the solenoid valve architecture inside the FC-R7800 handle aggressive etch gases?
A: Wetted flow paths utilize 316L stainless steel, magnetic stainless, and PTFE alongside all-metal 316L seals, eliminating elastomer swelling or chemical degradation when metering corrosive halogens and acidic vapors.

Q: Why is the negative 15 VDC current draw significantly higher than the positive rail?
A: The internal solenoid drive circuitry draws up to 180 mA from the -15 VDC rail to energize the coil against spring tension, whereas the +15 VDC rail (25 mA) primarily powers low-current sensor bridge and analog conditioning electronics.

Q: What symptoms appear if inlet pressure fluctuates near the 140 psig maximum rating?
A: While the mechanical body safely withstands 140 psig, exceeding the 40 psiD differential limit across the valve seat forces the solenoid outside its linear modulation band, causing flow overshoot or hunting.

Q: Can field technicians swap an existing 1/4" VCR analog controller with this unit without altering gas stick geometry?
A: Yes. The 183.8 mm port-to-port length and 28.6 mm width conform to standard semiconductor gas stick footprints, enabling direct mechanical replacement without re-bending orbital-welded tubing.

Q: How does thermal drift impact low-flow accuracy near the 2% turndown limit?
A: Because zero stability stays below 0.5% FS per year, maintaining a steady ambient temperature between 5°C and 45°C prevents thermal bridge offset, preserving tight repeatability even at low setpoints.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.