Home FC-R7710 AERA Analog Mass Flow Controller | FC-R7700 Series Mid-Flow

FC-R7710 AERA Analog Mass Flow Controller | FC-R7700 Series Mid-Flow

  • Manufacturer: AERA

  • Product No.: FC-R7710

  • Condition: In stock

  • Product Type: Mass Flow Controller

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Engineering Synopsis

The AERA FC-R7710 is an analog mass flow controller engineered for precision delivery of non-corrosive inert gases within the robust FC-R7700 series architecture. Utilizing a mid-flow capacity ranging from 6 to 50 slm, this elastomer-sealed device provides stable regulation for semiconductor processing tools including PVD, CVD, and sputter systems. Built with type 316(L) stainless steel wetted surfaces, it ensures clean, reliable performance across demanding industrial environments.

Technical Architecture & Performance Metrics

Performance Attribute Engineering Specification
Manufacturer Brand & Series AERA FC-R7700 Series
Exact Model Identifier FC-R7710
Mass Flow Capacity 6 to 50 slm (Normally-open: 6–20 slm; Normally-closed: 6–50 slm)
Set Point Accuracy ≤ ±2% of full scale
Repeatability & Zero Stability Repeatability: ≤ ±0.2% FS | Zero Drift: < 0.5% FS per year
Step Response Time < 3 seconds to within ±2% of full scale
Flow Linearity ≤ ±0.5% FS (≤ ±1% FS for ranges exceeding 30 slm)
Operating Pressure Windows Differential: 10–40 psiD (14–40 psiD high-flow N/C); Max inlet: 140 psig
Gas Media Support Inert and non-corrosive process gases (e.g., N2, O2, Ar)
Wetted Materials & Seals SUS316(L) stainless steel, PTFE, magnetic stainless with Fluoroelastomer/Chloroprene seals
Leak Integrity Ratings ≤ 1×10-6 atm-cc/sec (He); ≤ 1×10-7 Pa·m³/sec (He)
Analog Control Interface 0 to 5 VDC command and feedback via standard Aera 9-pin D sub-connector
Electrical Power Parameters +15 VDC at 25 mA; -15 VDC at 180 mA (3.1 W max consumption)
Physical Enclosure Dimensions 119 mm × 32 mm × 124 mm (Mid-size modular chassis)

Mechanical Integration & Setup Procedure

  1. Verify Gas Purity: Flush distribution manifolds with ultra-clean dry nitrogen prior to physical installation to eliminate particulate introduction.
  2. Check Flow Direction: Align the chassis flow arrow with the downstream process line, confirming secure mounting within the 119 × 32 × 124 mm envelope.
  3. Pinout Termination: Connect the 9-pin D control harness, ensuring shielded 0–5 VDC signal wires are isolated from high-voltage AC lines.
  4. Establish Differential Pressure: Set upstream regulators to maintain a stable 10–40 psiD differential across the valve body during active flow.
  5. Perform Zero Adjustment: Allow a 30-minute electronic warm-up before trimming zero output potential under static no-flow conditions.
  6. Diagnostic Protocols & Field Servicing

    • Solenoid Valve Response: Direct solenoid actuation delivers fast proportional control, though coil resistance should be verified periodically during routine turnarounds.
    • Elastomer Maintenance: Inspect elastomer seals for compression set or hardening during scheduled chamber overhauls, replacing seals when handling reactive gas shifts.
    • In-Situ Calibration: Utilize external flow standards to verify 0–5 VDC linearity curves annually without dismounting the mid-size chassis.

    System Compatibility & Standards

    • Chassis Interchangeability: Drop-in compatible with legacy FC-R7700 gas panel layouts and standard 9-pin analog cabling harnesses.
    • Process Suitability: Optimized for non-corrosive mid-flow utility lines in plasma etch, diffusion, and sputtering equipment racks.
    • Regulatory Compliance: Manufactured in accordance with RoHS environmental protection directives.

    Package Contents

    • 1 × AERA FC-R7710 Analog Mass Flow Controller
    • Factory calibration data verification report
    • Protective port plugs (installed for transit contamination control)

    Engineering Selection Guidelines

    Select normally-open variants for fail-safe gas venting requirements or normally-closed configurations for positive isolation during system power loss. Ensure operating gas viscosity matches factory calibration baselines to maintain stated ±2% full-scale accuracy.

    Frequently Asked Questions (FAQ)

    Q1: How does elastomer seal degradation impact long-term zero stability in the FC-R7710?

    A1: Elastomer micro-relaxation or gas permeation over extended thermal cycles can introduce minor baseline shift, which is easily corrected via the front zero-potentiometer adjustment.

    Q2: What precautionary steps prevent thermal drift when mounting this controller near high-heat process chambers?

    A2: Maintain ambient operating temperatures strictly between 5°C and 45°C and use thermal isolation standoffs if mounted adjacent to heated vacuum manifolds.

    Q3: Why is maintaining the 10 to 40 psiD differential pressure window critical for linear 0-5V response?

    A3: Insufficient differential pressure starves the internal solenoid valve of choked flow authority, causing non-linear flow distortion at the upper 80% span.

    Q4: Can this analog controller be retrofitted into older digital bus-based gas box architectures?

    A4: Yes, provided your system controller accepts standard 0–5 VDC analog command inputs and supplies dual ±15 VDC power rails through the 9-pin D interface.

    Q5: What purging protocol is recommended before removing the controller from corrosive or reactive service lines?

    A5: Execute a minimum of 10 vacuum-purge cycles using high-purity dry nitrogen to strip residual moisture before breaking mechanical seals.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.