Home Allen-Bradley 1756-IT6I2 ControlLogix Thermocouple Input Module

Allen-Bradley 1756-IT6I2 ControlLogix Thermocouple Input Module

  • Manufacturer: Allen-Bradley

  • Product No.: 1756-IT6I2

  • Condition: In stock

  • Product Type: Thermocouple Input Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 420g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Product Introduction

The Allen-Bradley 1756-IT6I2 is an enhanced thermocouple input module from the Rockwell Automation ControlLogix series. It provides six individually isolated analog input channels for temperature and millivolt measurements. The module supports multiple thermocouple types, including B, C, D, E, J, K, L, N, R, S, and T. Its 16-bit resolution enables detailed signal acquisition across configured input ranges. Two cold junction compensation (CJC) sensors support accurate thermocouple temperature conversion. Each CJC sensor provides an accuracy of ±0.3°C. The module uses sigma-delta analog-to-digital conversion and ITS-90 thermocouple linearization. Engineers can select integer or IEEE 32-bit floating-point data formats. The 1756-IT6I2 also provides configurable filtering, wire-off detection, process alarms, and rate alarms. These functions help engineers monitor temperature signals and identify abnormal sensor conditions.

Technical Specifications

Parameter Specification
Manufacturer Rockwell Automation
Brand Allen-Bradley
Model 1756-IT6I2
Product Series ControlLogix
Module Type Analog Thermocouple Input Module
Number of Channels 6 individually isolated inputs
CJC Sensors 2 integrated CJC inputs
Input Signal Thermocouple and millivolt
Input Resolution 16-bit
High-Resolution Range -12 to 30 mV
High-Resolution Sensitivity 0.7 µV/bit
Standard Input Range -12 to 78 mV
Standard Range Sensitivity 1.4 µV/bit typical
Input Impedance Greater than 10 MΩ
Maximum Overvoltage Protection 120 VAC/DC
Thermocouple Linearization ITS-90
CJC Sensor Accuracy ±0.3°C
Offset Drift 0.5 µV/°C
Channel Bandwidth 15 Hz
Settling Time Greater than 80 ms to 5% of full scale
Normal-Mode Noise Rejection 60 dB at 60 Hz
Common-Mode Noise Rejection Minimum 160 dB under specified test conditions
Open-Circuit Detection Positive full-scale indication within 2 seconds
Data Formats Integer and IEEE 32-bit floating point
Conversion Method Sigma-delta
Maximum Power Dissipation 4.6 W
Thermal Dissipation 15.7 BTU/hour
Backplane Current at 5V 200 mA
Backplane Current at 24V 150 mA (verify against the applicable hardware revision)
Compatible RTB 1756-TBNH, 1756-TBSH (verify module-specific wiring compatibility)

Thermocouple Input Types and Measurement Capabilities

The 1756-IT6I2 supports eleven thermocouple types. Engineers can configure individual channels for different sensor types.

Sensor Type Thermocouple Designation
B Type B
C Type C
D Type D
E Type E
J Type J
K Type K
L Type L (TXK/XK)
N Type N
R Type R
S Type S
T Type T

The supported temperature range depends on the selected thermocouple type. The module converts measured millivolt signals into engineering temperature values. The two CJC sensors compensate for reference-junction temperature variations. Their specified accuracy is ±0.3°C.

Signal Processing and Diagnostic Functions

The module provides configurable signal processing functions for industrial temperature monitoring.

  • Input range selection: Supports multiple millivolt measurement ranges.
  • Cold junction compensation: Uses two CJC sensors for thermocouple measurements.
  • Notch filtering: Helps suppress unwanted power-line frequency interference.
  • Digital filtering: Supports additional filtering in floating-point applications.
  • Real-time sampling: Provides periodic acquisition of channel data.
  • Wire-off detection: Identifies open thermocouple circuits.
  • Overrange detection: Identifies signals exceeding configured measurement limits.
  • Underrange detection: Identifies signals below configured measurement limits.
  • Process alarms: Monitors configured temperature thresholds.
  • Rate alarms: Detects temperature changes that exceed configured rates.
  • Temperature units: Supports configurable temperature representation.
  • 10-ohm offset: Provides an additional configurable offset function.

Data Processing and Controller Integration

The 1756-IT6I2 transfers acquired channel values and diagnostic information through the ControlLogix backplane. It supports two data formats:

  • Integer mode: Uses left-justified, two's-complement data.
  • Floating-point mode: Uses IEEE 32-bit floating-point representation.

The minimum module scan times depend on the selected format and measurement type.

Operating Mode Minimum Scan Time
Floating-point, millivolt 25 ms
Floating-point, temperature 50 ms
Integer, millivolt 10 ms

The module stores processed signals, diagnostic states, and configuration parameters in its data tables. ControlLogix programs can access these values for comparison instructions and arithmetic operations. Engineers can also use them in process alarms and temperature control algorithms.

Installation Guidelines

Install the 1756-IT6I2 in a compatible ControlLogix chassis. Follow these engineering recommendations:

  • Verify the catalog number and chassis compatibility before installation.
  • Confirm the available chassis slot and controller memory capacity.
  • Disconnect power before installing or removing the module.
  • Use the specified removable terminal block for field wiring.
  • Verify RTB compatibility before selecting the 1756-TBNH or 1756-TBSH.
  • Connect thermocouple wires using the correct polarity.
  • Use suitable thermocouple extension wire for each sensor type.
  • Separate low-level thermocouple wiring from high-voltage conductors.
  • Check terminal tightness and wiring insulation.
  • Confirm channel configuration before starting the measurement process.

For accurate temperature acquisition, maintain correct sensor polarity and cold junction compensation settings.

Compatibility and Selection Guide

The 1756-IT6I2 integrates with the Rockwell Automation ControlLogix platform. Before ordering, review these compatibility requirements:

  • Controller platform: Confirm compatibility with the installed ControlLogix processor.
  • Chassis: Check available slots and chassis power capacity.
  • Wiring accessories: Verify the required RTB and terminal housing.
  • Sensor selection: Match the configured input type with the thermocouple specification.
  • Signal range: Select the correct millivolt range for the application.
  • Software configuration: Confirm support for the module in the installed programming environment.
  • Data handling: Select integer or floating-point format according to controller requirements.

The module supports standalone ControlLogix systems and distributed I/O architectures. Actual installation limits depend on controller capacity and available chassis resources.

Certifications and Compliance

The supplied technical information does not identify specific certification numbers or approval marks for the 1756-IT6I2. Check the product nameplate and applicable Rockwell Automation documentation for the exact regulatory approvals. Verify project-specific requirements before installation in regulated or hazardous-area applications.

Package Contents

Standard product package description:

  • 1 × Allen-Bradley 1756-IT6I2 Thermocouple Input Module
  • Terminal block and wiring accessories: confirm separately when ordering
  • Product documentation: subject to the supplied package configuration

The removable terminal block may require separate ordering. Confirm whether the required 1756-TBNH or another approved accessory is included.

Frequently Asked Questions

Q1: What is the primary function of the Allen-Bradley 1756-IT6I2?

The module acquires thermocouple and millivolt signals through six individually isolated input channels. It converts these signals into digital values for ControlLogix temperature monitoring and process control.

Q2: Which thermocouple types does the 1756-IT6I2 support?

It supports B, C, D, E, J, K, L, N, R, S, and T thermocouples. Configure each channel according to its connected sensor.

Q3: What is the difference between the two input ranges?

The high-resolution range covers -12 to 30 mV with 0.7 µV/bit sensitivity. The standard range covers -12 to 78 mV with 1.4 µV/bit typical sensitivity. Select the range according to the expected sensor signal.

Q4: Why does this module include two CJC sensors?

Thermocouples require reference-junction compensation for accurate temperature conversion. The two CJC sensors measure reference-junction temperature conditions. Each sensor provides specified accuracy of ±0.3°C.

Q5: What should engineers check when temperature readings fluctuate?

Start by checking thermocouple polarity and terminal connections. Then inspect shielding, grounding, sensor condition, and CJC configuration. Incorrect sensor selection or electrical interference can also cause unstable readings.

Q6: Which removable terminal block should buyers select?

The supplied product information identifies the 1756-TBNH as the specified wiring accessory. It also mentions the 1756-TBSH. Confirm the exact RTB compatibility against the module revision and official wiring documentation before ordering.

Q7: Can the 1756-IT6I2 detect a disconnected thermocouple?

Yes. The module provides wire-off detection and reports an open-circuit condition through its diagnostic functions. Its specified detection response reaches a positive full-scale reading within two seconds.

Q8: Does the module support floating-point temperature data?

Yes. It supports IEEE 32-bit floating-point data and integer data formats. Floating-point mode also supports the module's digital filtering function.

Q9: How can engineers select a suitable replacement module?

Check the exact catalog number, chassis compatibility, input channel requirements, thermocouple types, and RTB configuration. Also verify controller software support and existing channel configuration. Do not select a replacement solely by its six-channel input count.

Q10: What should technicians verify before replacing an installed 1756-IT6I2?

Record the existing channel settings, thermocouple types, data format, filters, and alarm thresholds. Check the RTB wiring and controller configuration before removal. After installation, validate each channel against a known reference signal.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.