01 | Instrument Overview
The Bently Nevada 991-25-50-02-01 is a 991 Series thrust position transmitter for axial machinery monitoring.
It converts displacement measurements from a compatible 3300 NSv Proximity Probe system into a standardized 4–20 mA output.
The transmitter accepts one non-contacting proximity probe and its extension cable. It provides a two-wire current-loop signal for connection to PLC, DCS, and machinery monitoring systems.
This configuration includes a 25-0-25 mil full-scale option, a 5.0 m system length, bulkhead screw mounting, and CSA Division 2 approval.
02 | Technical Specification Matrix
| Manufacturer | Bently Nevada |
| Model | 991-25-50-02-01 |
| Product Series | 991 Series |
| Product Type | Thrust Position Transmitter |
| Manufacturing Origin | Made in U.S.A. |
| Measurement Direction | Axial |
| Full-Scale Option | 25-0-25 mils |
| System Length | 5.0 m (16.4 ft) |
| Mounting Option | Bulkhead Screws |
| Installation Type | DIN Rail |
| Input Sensor | One 3300 NSv Non-Contacting Proximity Probe |
| Output Signal | 4–20 mA DC |
| Output Configuration | Two-Wire Current Loop |
| Power Supply | +12 to +35 VDC at transmitter terminals |
| Prox Output Linear Range | 0.25 to 1.65 mm |
| Full-Scale Current-Loop Range | 0.6-0-0.6 mm or 25-0-25 mils |
| Typical Loop Accuracy | ±1.5% of specified full scale |
| Maximum Loop Resistance | 1,000 Ω, including cable, at 35 VDC |
| Current Limiting | 23 mA Typical |
| Transmitter Operating Temperature | -35°C to +85°C (-31°F to +185°F) |
| Storage Temperature | -51°C to +100°C (-60°F to +212°F) |
| Transmitter Weight | 0.43 kg (0.9 lb) |
03 | Ordering Code Architecture
Each suffix identifies a specific measurement, installation, or approval configuration.
| Code Segment | Selected Option | Configuration Meaning |
| 991 | Base Model | Thrust Position Transmitter |
| -25 | Full-Scale Option | 25-0-25 mils |
| -50 | System Length | 5.0 m (16.4 ft) |
| -02 | Mounting Option | Bulkhead Screws |
| -01 | Agency Approval | CSA Division 2 |
Complete Configuration Summary
- Transmitter: 991 Thrust Position Transmitter.
- Measurement Range: 25-0-25 mils.
- System Cable Length: 5.0 m.
- Mechanical Mounting: Bulkhead screws.
- Approval Selection: CSA Division 2.
- Signal Interface: Two-wire 4–20 mA DC.
04 | Measurement Principle and Signal Processing
The transmitter receives displacement information from a compatible 3300 NSv proximity measurement system. It converts the measurement into a proportional current-loop signal.
| Signal Condition | Output Behavior |
| Minimum Full-Scale Position | 4 mA |
| Midpoint Reference | 12 mA |
| Maximum Full-Scale Position | 20 mA |
| Not OK Condition | Below 3.6 mA within 100 μs |
| Signal Recovery | Within 0.1 seconds after fault removal |
Signal Interpretation: The 4–20 mA output represents the configured axial measurement range. The receiving controller must use the correct engineering-unit scaling.
The transmitter also provides a Not OK/Signal Defeat function. It drives the output below 3.6 mA when a Not OK condition occurs.
05 | Electrical Performance and Loop Design
Power Supply Requirements
- Required input: +12 to +35 VDC.
- Measure supply voltage at the transmitter terminals.
- Maintain sufficient voltage for the complete current-loop load.
Current-Loop Characteristics
- Output: 4–20 mA DC.
- Accuracy: Typically within ±1.5% of specified full scale.
- Maximum Loop Resistance: 1,000 Ω, including cable, at 35 VDC.
- Current Limiting: Approximately 23 mA.
- Zero Adjustment: External adjustment.
- Span Adjustment: External adjustment.
- Adjustment Interaction: Zero and span adjustments operate independently.
Accuracy Test Reference: The specified accuracy uses the TEST signal input and voltage measurement across a 250 Ω loop resistance.
When designing the receiving circuit, calculate the total loop resistance. Include input resistance, cable resistance, and other series-connected loads.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.