Home 5069-L340ERM Allen Bradley CompactLogix 5380 Motion Controller

5069-L340ERM Allen Bradley CompactLogix 5380 Motion Controller

  • Manufacturer: Allen-Bradley

  • Product No.: 5069-L340ERM

  • Condition: In stock

  • Product Type: Motion Controller

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 910g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Controller Architecture & Motion Control Capabilities

Machine builders deploy the 5069-L340ERM Allen Bradley CompactLogix 5380 standard controller to execute high-speed multi-axis motion and deterministic process control within a compact DIN-rail footprint. Equipped with 4 MB of user application memory and a bundled 2 GB 1784-SD2 non-volatile memory card, this Programmable Automation Controller (PAC) coordinates up to 20 integrated CIP motion axes alongside 31 local 5069 I/O modules. Its dual Gigabit EtherNet/IP ports support Device Level Ring (DLR) redundancy and Dual-IP network segmentation across up to 90 Ethernet nodes.

System Domain Engineering Parameter Rated Specification
Identification Manufacturer, Part Number & Line Allen Bradley 5069-L340ERM (CompactLogix 5380 / 5069)
Memory & Software User RAM, SD Storage & IDE 4 MB built-in RAM; 2 GB via 1784-SD2 card; Studio 5000 v31 or later
Motion Control CIP Axes & Total Motion Axes Up to 20 CIP drive axes; 256 total axes (Virtual, Consumed, Converters)
I/O & Special Functions Local Modules & High-Speed Capture 31 local 5069 I/O modules; hardware pulse latching & pattern matching
Communication Ports, Speeds & Topologies 2× 10/100/1000 Mbps EtherNet/IP (DLR, Star, Linear, Dual-IP); 1× USB 2.0 (12 Mbps)
Network Capacity Nodes & Socket Connections 90 total Ethernet nodes (55 EtherNet/IP nodes); 32 socket connections
MOD Power Bus Voltage, Draw & Bus Passthrough 18–32V DC range; 450 mA max draw (850 mA inrush/125 ms); 9.55 A bus rating
SA Field Power AC/DC Ratings & Passthrough 0–32V DC (10 mA max, 9.95 A bus) / 0–240V AC 47–63 Hz (25 mA max, 9.975 A bus; 125V AC max ATEX/IECEx)
Physical Shipping Weight & UPC 2.00 lbs (0.91 kg); UPC 887172922190

Key Engineering Advantages & Programming Standards

  • Dual-IP Network Isolation: Configure the dual Gigabit Ethernet ports independently to physically isolate high-speed CIP Sync servo drive traffic from enterprise SCADA, MES, and HMI communications.
  • Deterministic Servo Coordination: Supports 20 closed-loop CIP Drive axes plus virtual and regenerative AC/DC converter axes using IEC 61131-3 languages (Ladder Diagram, Structured Text, Function Block, Sequential Function Chart).
  • Segregated Power Architecture: Separates Module (MOD) logic power from Sensor/Actuator (SA) field power, enabling safe removal of field actuator voltage without dropping controller backplane communication.
  • Standard Non-Safety Architecture: Engineered specifically for high-throughput standard automation and motion tasks (for integrated GuardLogix SIL 3/PLe safety functions, specify a 5069-L340ERMS2/ERMS3 model).

Field Engineering FAQ

Q1: How do I configure the dual EtherNet/IP ports on the 5069-L340ERM for Dual-IP mode versus DLR mode?

A1: Open the controller properties in Studio 5000 Logix Designer (version 31 or later), navigate to the Network Configuration tab, and toggle between Linear/DLR mode (single IP address across both ports) and Dual-IP mode (two separate subnet IP addresses).

Q2: What happens if I exceed the 9.55 A MOD power or 9.95 A SA field power passthrough limits across 31 local I/O modules?

A2: Exceeding backplane current capacity causes voltage sag and intermittent module faults. Insert a 5069-FPD Field Potential Distributor module mid-bank to inject a fresh 24V DC power bus segment for downstream high-density I/O slices.

Q3: Can I open a project created in Studio 5000 v30 or earlier on this controller?

A3: No, the 5069-L340ERM hardware firmware requires Studio 5000 Logix Designer version 31 or higher. You must convert legacy L5K or ACD project files up to v31+ prior to downloading.

Q4: Why is the bundled 1784-SD2 2 GB SD card critical during unmanned night-shift maintenance?

A4: By setting the controller's non-volatile load option to "On Power Up" or "On Corrupt Memory," the processor automatically reloads the user program and firmware from the 1784-SD2 card after severe power transients without requiring an engineer with a laptop.

Q5: How do hardware pulse latching and pattern matching improve high-speed packaging machine accuracy?

A5: Built-in hardware pulse latching captures registration sensor edges directly at the bus level independent of main PLC scan times, eliminating variable scan jitter during high-speed rotary knife cutting and label application.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.