140DAO84000 Schneider Modicon Quantum 16 Channel AC Discrete Output Module
Manufacturer: Schneider Electric
Product No.: 140DAO84000
Condition: In stock
Product Type: Discrete Output Module
Product Origin: DE
Payment: T/T, Western Union
Weight: 621g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview
The 140DAO84000 is a high-density 16-point AC discrete output module.
It is designed for the Schneider Electric Modicon Quantum automation platform.
Featuring 16 channel-to-channel isolated output groups, it independently switches line voltages from 20 to 253 VAC.
Built-in RC snubber circuits deliver robust dv/dt transient suppression up to 400 V/µs.
This module drives heavy inductive loads, including large motor contactors, solenoids, and control relays.
Functional & Architectural Breakdown
-
140DAO84000 — 16-Channel Isolated AC Output Module
- Platform Compatibility — Standard slot interface for Modicon Quantum backplanes.
- Isolation Architecture — 16 individual groups (1 channel per group) allowing multi-phase wiring.
- Operating Voltage Range — 20 VAC to 253 VAC continuous rating (47 Hz to 63 Hz supply frequency).
- Thermal Dissipation — Calculated via formula: 1.85 W + (1.1 V x total module load current).
- Backplane Bus Draw — Consumes 350 mA at 5 VDC logic supply.
- Addressing Requirement — Occupies exactly 1 output word in Quantum CPU memory allocation.
Technical Specifications
| Specification Category | Engineering Parameter Value |
|---|---|
| Brand | Schneider Electric / Modicon |
| Model Number | 140DAO84000 |
| Product Series | Modicon Quantum Automation Platform |
| Output Type | Solid-State Isolated AC Discrete Output |
| Number of Output Channels | 16 channels (16 groups of 1 channel each) |
| Rated Operating Voltage | 20 to 253 VAC rms |
| Max Voltage Drop | 1.5 V at maximum continuous load current |
| Continuous Output Current | 4 A rms per point (24-115V) / 3 A rms per point (200-230V) |
| Module Total Thermal Limit | 16 A rms continuous maximum per module |
| Surge Current Capacity | 30 A (1 cycle), 20 A (2 cycles), 10 A (3 cycles) per point |
| Off-State Leakage Current | 1 mA @ 24V, 1 mA @ 48V, 2 mA @ 115V, 2.5 mA @ 230V rms max |
| Response Switching Speed | Turn-On ≤ 0.5 ms / Turn-Off ≤ 0.5 ms |
| Transient dv/dt Immunity | 400 V/µs internal RC filter protection |
| External Branch Fusing | 5 A fast-acting fuse per output group recommended |
| Local Diagnostic LEDs | 1 Green (Active), 1 Red (External Fault F), 16 Green (Channel Status) |
Hardware Configuration & Wiring Setup
- Verify that field wiring supply voltages remain strictly within the 20 to 253 VAC operating window.
- Ensure each output group is protected using an inline 5 A fast-acting fuse to prevent solid-state switch damage.
- Maintain total module continuous current below 16 A rms across all 16 active channels combined.
- Confirm field ground connections meet IEC 801-2 noise immunity limits (4 kV contact / 8 kV air discharge).
- Tighten terminal strip retention screws to avoid contact resistance under high ambient vibration.
Warranty Terms & Express Global Logistics
- Supplied with a full 12-Month comprehensive replacement warranty covering functional reliability.
- Protected in ESD-safe sealed packaging and dispatched within 24 to 48 hours of order clearance.
- Worldwide expedited freight delivered via FedEx, UPS, and DHL air express networks.
Typical Applications & Diagnostic Capabilities
- Direct switching of 115 VAC / 230 VAC heavy contactor coils in power distribution centers.
- Actuation of pneumatic and hydraulic solenoids in water treatment and chemical dosing skids.
- Control of multi-phase industrial heaters and alarm annunciators requiring channel-to-channel isolation.
- Front LED diagnostics: Green Active LED indicates backplane bus health; Red F LED alerts operators to external fault conditions; 16 green point LEDs show real-time logic output states.
Global PLC Spare HUB's Insight
High-density AC output cards in legacy plant racks often present unexpected field troubleshooting challenges.
During a system retrofit on a paper mill boiler control panel, technicians experienced intermittent "false ON" states on low-power 230 VAC intermediate relays.
Investigation revealed that off-state leakage current through internal RC snubbers (up to 2.5 mA at 230 V) held high-impedance relay coils energized even when the PLC output bit was OFF.
Installing parallel loading resistors across the load terminals or selecting the fully channel-isolated 140DAO84000 eliminated leakage pickup and restored reliable contact dropout performance.
Frequently Asked Questions (FAQ)
Q: Why do low-power 230 VAC relay coils remain chatter-energized when an AC output channel is in the OFF state?
A: Solid-state AC outputs utilize internal RC snubber networks that pass off-state leakage current (up to 2.5 mA at 230 V). For low-impedance loads, adding a parallel bleeder resistor across load terminals absorbs this leakage voltage.
Q: Can individual output channels on the 140DAO84000 card be connected to different AC phase legs?
A: Yes, because the card features 16 individual isolated groups (1 channel per group), each output can be wired to distinct AC phase lines or separate control transformers without risking cross-phase short circuits.
Q: How does this module handle heavy inductive inrush currents from large solenoid actuators?
A: Each channel features high peak surge tolerance, withstanding up to 30 A for 1 cycle or 10 A for 3 cycles, absorbing initial inductive surge spikes without tripping output faults.
Q: What physical and electrical steps should be verified prior to installing a spare Quantum AC output card into an active rack?
A: Inspect backplane gold-finger connectors for contamination, confirm that the front Green Active LED turns solid upon chassis power-up, and verify that total continuous load current across all 16 points does not exceed 16 A rms.
Q: Are individual output channels internally fused against load short circuits?
A: No, internal protection is limited to RC transient filters. External 5 A fast-acting branch fuses must be installed on each channel circuit to protect internal solid-state switches from direct short faults.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.