  • Manufacturer: Honeywell

  • Product No.: XNX-AMSE-RHNNN

  • Condition: En stock

  • Product Type: Universal Transmitter

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 6800g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

Overview

The XNX-AMSE-RHNNN Honeywell Universal Transmitter delivers precision toxic gas monitoring and oxygen depletion detection across high-consequence processing operations. Engineered with a painted 316 stainless steel enclosure, this unit contains an integrated intrinsically safe (IS) barrier and interface adapter tailored for plug-and-play electrochemical (EC) sensor cartridges. Instrumentation specialists gain dual-output safety coverage: analog 4-20mA signal transmission with HART digital protocol, plus three internal electromechanical relays for direct hardware interlocks.

Configuration Architecture Breakdown

  • Honeywell XNX Series Platform
    • Approval Rating [A]: ATEX / IECEx Hazardous Zone Certified
    • Thread Entry [M]: 5 x M25 Threaded Gland Entries
    • Housing Material [S]: Painted 316 Marine-Grade Stainless Steel (6.8 kg)
    • Personality Interface [E]: Electrochemical (EC) Cartridges (Includes IS Barrier & Adaptor)
    • Internal Hardware Option [R]: 3 x Form "C" SPCO Relays Installed (2 Alarm, 1 Fault)
    • Local Diagnostic Interface [H]: Integrated External Local HART Port
    • Sensor Selection [NNN]: Base Transmitter Frame (Electrochemical Cell Sold Separately)

Technical Specifications & Operating Boundaries

Engineering Parameter Field Specification Detail
Manufacturer Name Honeywell
Full Order Part Number XNX-AMSE-RHNNN
Product Line Honeywell XNX Universal Gas Transmitter
Sensor Compatibility Honeywell XNX Toxic Gas & Oxygen (O2) Electrochemical Cartridges
Internal Safety Circuitry Built-in Intrinsically Safe (IS) Galvanic Isolation Barrier
Primary Communication 4-20mA Analog Current Loop with HART Digital Protocol
Secondary Contact Output 3 x SPCO Relays (250 VAC / 24 VDC @ 5A Resistive Load)
Local Calibration Port External Intrinsically Safe Local HART Connection Port
Ingress Rating IP66 Weatherproof and Dust-Tight Enclosure Rating
Operating Temperature -40°C to +65°C (-40°F to +149°F) Base Unit Enclosure Limits
Ambient Humidity Range 0 to 99% RH Non-Condensing Operating Window
Operating Air Pressure 80 kPa to 120 kPa Absolute Pressure Standard
Unit Net Weight 6.8 Kg (Heavy-Duty Stainless Steel Construction)

Compatible Hardware & Operational Deployments

  • Target Electrochemical Sensing Cartridges:
    • Hydrogen Sulfide (H2S), Carbon Monoxide (CO), Chlorine (Cl2), Ammonia (NH3), and Hydrogen (H2) Toxic Cells.
    • Oxygen (O2) Depletion and Enrichment Electrochemical Sensors.
  • Ideal Industrial Facilities:
    • Offshore oil platforms, FPSOs, and marine chemical transport terminals requiring 316SS corrosion protection.
    • Wastewater treatment plants, sludge digestors, and municipal chemical dosing rooms.
    • Semiconductor manufacturing sub-fab areas, gas storage vaults, and battery energy storage skids.

Diagnostic & Predictive Self-Monitoring Capabilities

The XNX-AMSE-RHNNN Honeywell transmitter features continuously active self-diagnostic firmware that verifies internal memory integrity, galvanic barrier loop resistance, loop voltage, and sensor cell response baseline. If an electrochemical cell suffers electrolyte dry-out, pin degradation, or signal drift beyond safety limits, the unit automatically drops its 4-20mA loop output to fault status (≤2.0mA) and trips the dedicated internal Fault Relay contact, preventing false-safe readings during critical process excursions.

Model Selection Comparison & Engineering Recommendation

Evaluating mechanical casing materials, sensor input types, and internal hardware options ensures proper safety loop deployment. Below is a side-by-side engineering comparison between the XNX-AMSE-RHNNN transmitter and the alternative XNX-AMAV-NHNNN model configuration:

Selection Specification XNX-AMSE-RHNNN XNX-AMAV-NHNNN
Input Personality Type 'E' Personality (Electrochemical Toxic / O2 with IS Barrier) 'V' Personality (mV Bridge for Catalytic Bead / MPD)
Enclosure Construction Painted 316 Stainless Steel Housing (6.8 kg) Painted LM25 Marine-Grade Aluminum (2.8 kg)
Internal Relay Option 3 x SPCO Mechanical Relays Included No Relays Installed (Loop-Powered / Signal Only)
Local HART Connection Integrated External Local HART Port Included Integrated External Local HART Port Included
Entry Thread Size 5 x M25 Metric Entry Ports 5 x M25 Metric Entry Ports

Engineering Advice: Specify the XNX-AMSE-RHNNN for toxic gas or oxygen monitoring applications situated in highly corrosive salt-mist environments where direct local alarm relay tripping (horns, exhaust fans, valve actuators) is required. Select the XNX-AMAV-NHNNN when measuring flammable hydrocarbon gases via catalytic bead sensors, where weight constraints favour aluminum enclosures, and all alarm logic is processed centrally by a DCS or Safety PLC system.

Global PLC Spare HUB's Insight

On a recent offshore wastewater skid retrofitting project, maintenance personnel reported frequent transducer corrosion and ground loop interference when installing standard toxic gas sensors. Upgrading the system to the XNX-AMSE-RHNNN Honeywell resolved both challenges. The 316SS housing eliminated salt spray degradation, while the built-in IS barrier permitted safe hot-swapping of H2S electrochemical cartridges. Utilizing the external local HART port allowed field technicians to perform routine zero calibrations using handheld calibrators without unsealing the flameproof enclosure or acquiring a hot-work permit.

Warranty Terms, Logistics & Shipping

  • Product Condition: 100% Brand New Original Factory Supply
  • Warranty Guarantee: Standard 12-Month Quality Warranty from dispatch date
  • Order Processing Time: Rapid turnaround, shipping within 24 to 48 hours post-payment verification
  • Global Logistics Express: Express door-to-door delivery via FedEx, UPS, and DHL Express networks

Engineering Selection & Application FAQ

What is the function of the internal IS barrier built into the 'E' personality model?

The integrated intrinsically safe barrier restricts electrical energy going to the electrochemical cell socket, allowing field operators to replace toxic gas sensor cartridges safely under power without opening the main enclosure or de-classifying the hazardous area.

Can I install an infrared or catalytic bead sensor into this 'E' personality transmitter?

No. The internal personality board on this model is calibrated specifically for electrochemical toxic and oxygen cells. Infrared or millivolt catalytic sensors require different transmitter personality configurations such as 'I' or 'V'.

How does the local external HART port facilitate field servicing?

The external HART connection on the bottom of the enclosure allows technicians to plug in an intrinsically safe HART communicator directly in hazardous zones, enabling rapid diagnostic checks without disturbing internal terminal wiring.

Why is the 316 stainless steel casing recommended for offshore toxic gas detection?

Toxic gases like H2S combined with marine salt mist quickly pit and degrade standard aluminum housings over time. Heavy-duty 316 stainless steel prevents structural degradation, preserving the explosion-proof boundary for years of continuous service.

Are the three internal SPCO relays independently configurable for different alarm thresholds?

Yes. Through the magnetic wand menu interface or HART protocol, engineers can independently program alarm 1, alarm 2, and fault relay trigger points, energize/de-energize states, and latching modes to drive custom local emergency shutdown sequences.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.