722B12TCD2FA MKS Instruments 4-VCR Precision Pressure Sensor
Manufacturer: MKS Instruments
Product No.: 722B12TCD2FA
Condition: En stock
Product Type: Absolute Pressure Sensor
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).
Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.
Pago Seguro Garantizado
Product Overview | Compact Absolute Pressure Measurement
MKS Instruments 722B12TCD2FA is a compact absolute pressure transducer from the Baratron® 722B Series. It uses capacitance diaphragm technology to measure vacuum and process pressure independently of gas composition.
This configuration provides a 100 Torr full-scale range and ±0.5% of reading accuracy. Its process interface uses a female 4-VCR fitting. A 9-pin Type D connector handles power and analog signal connections.
The transducer accepts +13 to +32 VDC and provides a proportional 0–10 VDC output. Its all-metal wetted construction uses Inconel® for compatibility with many industrial process gases.
A response time below 20 milliseconds supports dynamic pressure monitoring. The robust sensor construction also tolerates specified pressure excursions. These characteristics make the 722B12TCD2FA suitable for vacuum equipment, semiconductor systems, and industrial process monitoring.
01 | Configuration Breakdown – Model Suffix Analysis
The complete ordering code identifies the pressure range, process fitting, electrical configuration, accuracy, and connector. Each suffix defines a specific hardware requirement.
| Code Segment | Configuration | Technical Meaning |
| 722B | Product Series | Compact general-purpose absolute Baratron® capacitance manometer |
| 12T | Pressure Range | 100 Torr full scale |
| CD | Process Fitting | 1/4-inch 4-VCR female connection |
| 2 | Input / Output | +13 to +32 VDC input / 0–10 VDC output |
| F | Accuracy Grade | ±0.5% of reading |
| A | Electrical Connector | 9-pin Type D connector |
Complete Model: 722B12TCD2FA
Configuration Architecture:
- Pressure Measurement: 100 Torr absolute pressure.
- Vacuum Connection: Female 4-VCR process fitting.
- Power Architecture: Single positive DC supply, +13 to +32 VDC.
- Signal Architecture: 0–10 VDC proportional analog output.
- Measurement Accuracy: ±0.5% of reading.
- Electrical Interface: 9-pin D-subminiature connector.
Configuration Distinction: The CD suffix specifies 4-VCR female. The CE suffix specifies 8-VCR female. These fittings are not interchangeable, so verify the complete ordering code before purchasing.
02 | Technical Specification Register
| Parameter | Specification |
| Manufacturer | MKS Instruments, USA |
| Model | 722B12TCD2FA |
| Product Series | Baratron® 722B |
| Product Type | Capacitance Diaphragm Pressure Transducer |
| Measurement Type | Absolute Pressure |
| Full-Scale Range | 100 Torr |
| Accuracy | ±0.5% of reading |
| Response Time | Less than 20 ms |
| Analog Output | 0–10 VDC |
| Minimum Output Load | Greater than 10 kΩ |
| Power Supply | +13 to +32 VDC |
| Maximum Supply Current | 10 mA |
| Process Fitting | 1/4-inch 4-VCR female |
| Electrical Connector | 9-pin Type D |
| Wetted Material | Inconel® |
| Wetted Surface Finish | ≤10 Ra |
| Operating Temperature | 0°C to 50°C |
| Zero Temperature Coefficient | 0.008% F.S./°C |
| Span Temperature Coefficient | 0.04% of reading/°C |
| Overpressure Limit | 45 psia or 2 × F.S., whichever is greater |
| Burst Pressure | 10 × F.S. or 100 psi, whichever is greater |
03 | Sensing Technology and Measurement Characteristics
The Baratron® 722B measures pressure through capacitive changes in a precision diaphragm assembly.
Pressure acts on the sensing diaphragm and produces mechanical displacement. The internal electronics convert the resulting capacitance variation into a proportional voltage signal.
This measurement method offers several engineering advantages:
- Gas-Independent Measurement: The sensing principle does not depend on gas thermal conductivity.
- Absolute Pressure Reference: Measures pressure against an internal reference vacuum.
- Fast Response: The specified response time remains below 20 milliseconds.
- Stable Measurement: The accuracy specification includes non-linearity, hysteresis, and non-repeatability.
- Corrosion Resistance: Inconel® wetted surfaces support compatibility with many process gases.
- Clean Surface Construction: Wetted surfaces receive a controlled finish of ≤10 Ra.
Accuracy Definition: The ±0.5% specification refers to the pressure reading. It does not represent ±0.5% of full scale.
04 | Analog Output and Electrical Interface
The 722B12TCD2FA uses a 0–10 VDC output for integration with compatible pressure controllers and industrial analog input systems.
| Electrical Parameter | Specification |
| Supply Voltage | +13 to +32 VDC |
| Supply Current | 10 mA maximum |
| Output Signal | 0–10 VDC |
| Output Load | Greater than 10 kΩ |
| Connector Type | 9-pin Type D |
| Signal Reference | Pressure Return |
| Power Reference | Power Return |
Nominal Signal Scaling: The 100 Torr full-scale range corresponds to a 0–10 VDC output.
- 0 Torr corresponds to approximately 0 VDC.
- 25 Torr corresponds to approximately 2.5 VDC.
- 50 Torr corresponds to approximately 5 VDC.
- 75 Torr corresponds to approximately 7.5 VDC.
- 100 Torr corresponds to approximately 10 VDC.
These values represent nominal linear scaling. Actual readings depend on calibration and instrument specifications.
05 | 9-Pin D-Sub Connector Pin Assignment
The following pinout follows the MKS 722B instruction manual. Keep the pressure signal return and power return connections distinct during cable assembly.
| Pin Number | Signal Assignment | Function |
| Pin 1 | Pressure Output | 0–10 VDC analog pressure signal |
| Pin 2 | No Connection | Not internally connected |
| Pin 3 | No Connection | Not internally connected |
| Pin 4 | + Power Input | +13 to +32 VDC supply |
| Pin 5 | No Connection | Not internally connected |
| Pin 6 | No Connection | Not internally connected |
| Pin 7 | No Connection | Not internally connected |
| Pin 8 | Pressure Return | Analog signal reference |
| Pin 9 | Power Return | DC supply return |
Wiring Precaution: Do not assume that pressure return and power return are interchangeable. Follow the MKS wiring diagram and compatible controller requirements.
Verify connector orientation before assigning pin numbers. Incorrect wiring can cause unstable readings or damage connected equipment.
06 | Pressure Limits and Thermal Performance
The sensor construction supports pressure excursions beyond its normal measurement range. Engineers must distinguish the specified overpressure limit from the burst pressure rating.
| Parameter | Value |
| Full-Scale Pressure | 100 Torr |
| Overpressure Limit | 45 psia or 2 × full scale, whichever is greater |
| Burst Pressure | 10 × full scale or 100 psi, whichever is greater |
| Operating Temperature | 0°C to 50°C |
| Zero Temperature Coefficient | 0.008% F.S./°C |
| Span Temperature Coefficient | 0.04% of reading/°C |
Engineering Note: Overpressure tolerance does not authorize continuous operation above the rated measurement range. Avoid unnecessary pressure surges during system venting and pump-down.
07 | Vacuum Connection and Wetted Material
The CD fitting configuration provides a female 4-VCR process interface. It supports compatible metal-gasket vacuum connections.
- Fitting Type: 1/4-inch 4-VCR female.
- Wetted Material: Inconel® nickel-based alloy.
- Surface Finish: ≤10 Ra on wetted surfaces.
- Construction: All-metal sensor wetted surfaces.
- Material Compatibility: Suitable for many compatible semiconductor and industrial process gases.
Some optional fitting configurations use 316 stainless steel. The standard wetted sensor surfaces use Inconel®. Confirm the actual fitting material when chemical compatibility is critical.
Installation Warning: Use compatible VCR gaskets and approved assembly procedures. Do not apply excessive tightening force to the fitting or sensor body.
08 | Installation and Commissioning Guide
Proper installation protects the sensing diaphragm and maintains vacuum system integrity. Complete the following checks before applying operating pressure.
Mechanical Installation
- Verify the 4-VCR female connection against the process tubing.
- Inspect the sealing surfaces before installing the gasket.
- Use compatible metal gaskets for the process conditions.
- Check the mounting position and avoid unnecessary mechanical stress.
- Inspect all vacuum joints for leakage after assembly.
Electrical Installation
- Provide a regulated +13 to +32 VDC supply.
- Connect the positive supply to Pin 4.
- Connect the power return to Pin 9.
- Connect the analog output through Pin 1.
- Connect the pressure return through Pin 8.
- Verify the receiving input impedance exceeds 10 kΩ.
Commissioning Sequence
- Inspect the complete electrical and vacuum connections.
- Verify the power supply voltage and polarity.
- Allow the instrument to reach stable operating conditions.
- Check the analog output at a known pressure.
- Compare readings against a calibrated reference instrument.
- Configure the PLC or controller for a 0–100 Torr range.
- Perform a final leak and signal stability check.
09 | Maintenance and Troubleshooting
The compact sensor architecture simplifies integration into vacuum equipment. Routine checks should focus on pressure connections, power quality, and analog signal integrity.
| Observed Problem | Engineering Inspection |
| Output remains at zero | Check supply voltage, Pin 4, Pin 9, and pressure conditions. |
| Output fluctuates unexpectedly | Inspect grounding, shielding, and analog input stability. |
| Reading differs from reference | Verify calibration, temperature, and controller scaling. |
| Pressure does not stabilize | Inspect vacuum joints, process leakage, and pump performance. |
| Incorrect PLC reading | Check signal return, input impedance, and 0–10 V configuration. |
| Sudden measurement shift | Investigate pressure surges and abnormal process conditions. |
Maintenance Recommendation: Inspect the VCR sealing interface whenever technicians disconnect the sensor. Replace damaged sealing components and repeat the leak test after reassembly.
10 | System Compatibility and Integration
The MKS Baratron 722B supports vacuum control systems with compatible DC power and voltage-input measurement channels.
- PLC Systems: Use a 0–10 VDC analog input module.
- DCS Systems: Connect through a compatible voltage signal acquisition channel.
- Vacuum Controllers: Integrate with controllers supporting the 722B electrical interface.
- Semiconductor Equipment: Monitor absolute pressure in compatible process chambers.
- Vacuum Process Equipment: Provide pressure feedback for monitoring and control.
Compatibility Requirements:
- Verify the +13 to +32 VDC supply requirement.
- Confirm the controller accepts a 0–10 VDC signal.
- Maintain an input impedance above 10 kΩ.
- Match the female 4-VCR fitting with the process connection.
- Confirm the 9-pin D-sub pinout before cable fabrication.
Do not connect the output directly to a 4–20 mA input. Use an appropriate signal converter when the existing control system lacks voltage-input capability.
11 | Typical Industrial Applications
- Semiconductor Manufacturing: Monitor vacuum pressure in compatible process chambers.
- Thin-Film Deposition: Provide pressure feedback during vacuum coating operations.
- Vacuum Processing: Measure absolute pressure in industrial vacuum equipment.
- Research Laboratories: Support controlled pressure measurement in experimental systems.
- Vacuum Equipment Integration: Supply analog pressure signals to automation controllers.
- Process Monitoring: Track pressure changes during production and equipment operation.
12 | Product Selection and Replacement Guidance
When selecting a replacement for an existing Baratron® transducer, compare the complete ordering code rather than the series name alone.
| Selection Criteria | Required Configuration |
| Product Series | 722B |
| Measurement Range | 100 Torr |
| Fitting | 4-VCR female |
| Power Input | +13 to +32 VDC |
| Signal Output | 0–10 VDC |
| Accuracy | ±0.5% of reading |
| Connector | 9-pin Type D |
Important Selection Distinction: The 722B12TCD2FA and 722B12TCE2FA share the 100 Torr range and electrical configuration. However, CD specifies 4-VCR female, while CE specifies 8-VCR female.
Do not substitute these configurations without checking the process connection. Also verify the power supply and controller scaling when replacing older pressure transducers.
13 | Packaging, Warranty and International Shipping
- Product: MKS Instruments 722B12TCD2FA Baratron® Pressure Transducer.
- Configuration: 100 Torr, 4-VCR female, 0–10 VDC output.
- Electrical Interface: 9-pin D-sub connector.
- Packaging: Protective packaging for precision industrial instrumentation.
- Documentation: Product identification and available technical documentation.
Warranty: 12-month seller warranty.
Shipping Options: FedEx, UPS, and DHL international delivery.
Product Condition: New and original factory-supplied equipment.
Ordering Note: Confirm the fitting, connector, and complete model suffix before ordering. Cables, gaskets, controllers, and additional accessories require separate confirmation.
14 | Frequently Asked Questions
Q1: Can the 722B12TCD2FA measure pressure when the process gas composition changes?
Yes. Its capacitance diaphragm principle measures pressure through mechanical displacement rather than gas thermal conductivity. Changes between compatible process gases do not require thermal conductivity correction factors. Engineers must still evaluate chemical compatibility with exposed materials.
Q2: Why is the separation between pressure return and power return important?
These connections serve different electrical functions. Pin 8 provides the pressure signal reference. Pin 9 provides the power return. Incorrect grounding arrangements can introduce measurement errors or damage connected equipment. Follow the specified interface diagram during cable fabrication.
Q3: How should engineers evaluate pressure spikes during pump switching?
Monitor pressure changes during pump startup, isolation valve operation, and chamber venting. Compare transient pressure against the specified overpressure limit. The protective rating helps tolerate occasional excursions, but it does not replace proper pressure management.
Q4: Can a 100 Torr transducer replace a 250 Torr or 500 Torr model?
Not automatically. A lower full-scale range changes the pressure-to-voltage relationship and the available measurement span. Check the maximum process pressure and controller scaling before substitution. Select a range that accommodates normal operation and expected pressure excursions.
Q5: What should purchasing engineers verify when ordering a replacement for a CD or CE configuration?
Check the exact VCR fitting size, connector type, output voltage, and power requirement. CD identifies 4-VCR female, while CE identifies 8-VCR female. Request confirmation using the complete nameplate model number. This check helps prevent mechanical installation problems and unnecessary system modifications.
Precision Baratron Pressure Measurement for Vacuum Systems
The MKS Instruments 722B12TCD2FA combines 100 Torr absolute pressure measurement with ±0.5% reading accuracy and a compact capacitance diaphragm design.
Its female 4-VCR process connection, 9-pin D-sub interface, and 0–10 VDC output support integration into compatible vacuum equipment. Inconel® wetted surfaces and fast response make this configuration suitable for demanding industrial pressure monitoring applications.
Contact us for a quotation, stock availability, delivery information, or replacement verification. Provide your complete model number and application requirements for technical assistance.
Tags
P: ¿Son estas piezas 100% originales y nuevas?
R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.
P: ¿Qué tan rápido es el envío a mi país?
R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.
P: ¿Puedo obtener una cotización formal con los costos de envío?
R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.
P: ¿Ofrecen descuentos por pedidos al por mayor?
R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.
Garantía Integral de 12 Meses
Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.
- Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
- Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.
Política de Devoluciones y Cambios
Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.
- Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
- Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
- Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.
¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.



