Inicio 626C11TDE MKS Baratron 626C Precision 10 Torr Vacuum Transducer

626C11TDE MKS Baratron 626C Precision 10 Torr Vacuum Transducer

  • Manufacturer: MKS Instruments

  • Product No.: 626C11TDE

  • Condition: En stock

  • Product Type: Vacuum Transducer

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

MKS Instruments 626C11TDE Baratron Absolute Pressure Transducer

The 626C11TDE is an MKS Instruments Baratron® 626C Series non-heated capacitance diaphragm pressure transducer. It measures absolute pressure in vacuum systems operating within a 10 Torr full-scale range. Its room-temperature design suits applications that do not require a heated sensing assembly.

The transducer provides a stated accuracy of ±0.25% of reading and a linear 0–10 VDC analog output. It operates from a ±15 VDC supply and uses a nickel-alloy sensing construction, according to the supplied product information. These characteristics support precise vacuum monitoring in semiconductor equipment, laboratory systems, and industrial process installations.

1. Product Configuration at a Glance

Configuration Item Code Specification
Product Series 626C Non-heated Baratron absolute capacitance manometer
Pressure Range 11T 10 Torr full scale
Connection Option D Mechanical connection code; confirm the exact interface before ordering
Electrical / Accuracy Option E 15-pin D-sub electrical interface and stated ±0.25% of reading accuracy; verify the complete option definition against the MKS configuration record

Important interface note: The supplied information describes the D connection in two different ways: 1/2-inch Tube and NW16-KF. These are different mechanical interfaces and are not directly interchangeable. Confirm the actual flange or tube connection from the installed unit, equipment drawing, or manufacturer documentation before selecting a replacement.

2. Technical Data and Operating Limits

Specification Value
Manufacturer MKS Instruments
Product Family Baratron®
Series 626C
Model Number 626C11TDE
Product Type Non-heated absolute capacitance diaphragm pressure transducer
Full-Scale Range 10 Torr absolute
Pressure Equivalent Approximately 13.33 mbar / 1.33 kPa
Accuracy ±0.25% of reading
Analog Output 0–10 VDC, linear
Output Load Greater than 10 kΩ
Power Supply ±15 VDC ±5%
Supply Current 35 mA
Electrical Connector 15-pin D-sub, as supplied
Wetted Materials Inconel® and Incoloy® nickel-based alloys, as supplied
Maximum Overpressure 45 psia / approximately 310 kPa
Operating Temperature 0°C to 50°C

3. How the 626C Measures Absolute Pressure

The 626C uses a capacitance diaphragm measurement principle. Pressure applied to the sensing diaphragm causes a small mechanical displacement. The instrument detects the resulting capacitance change and converts it into a proportional electrical output.

  • Absolute reference: The measurement references an internal vacuum rather than local atmospheric pressure.
  • Gas-independent response: The sensing principle measures mechanical pressure rather than gas thermal conductivity or ionization characteristics.
  • Continuous analog feedback: The 0–10 VDC output supports integration with compatible controllers and monitoring equipment.
  • Non-heated construction: The sensor operates without a dedicated heated sensing chamber, making ambient-temperature compatibility an important selection factor.

For process engineers, the key advantage is consistent pressure measurement without the gas-composition correction required by some alternative vacuum measurement technologies. However, process contamination and material compatibility still require careful evaluation.

4. Typical Industrial Applications

Application Area Measurement Role Engineering Consideration
Semiconductor vacuum equipment Chamber pressure monitoring Check process cleanliness and the required pressure range.
Vacuum coating systems Pressure feedback during vacuum processing Verify the output scaling used by the control system.
Laboratory vacuum systems Absolute pressure measurement Confirm that the 10 Torr range matches the operating window.
Industrial process chambers Vacuum status and process monitoring Evaluate gas compatibility and possible contamination.
Vacuum control assemblies Analog pressure feedback to controllers Check electrical loading and signal grounding.

5. Electrical Integration and Commissioning

Correct electrical integration is essential for accurate pressure feedback. Before connecting the transducer, verify the power supply, signal interface, and controller input configuration.

  1. Power verification: Confirm a ±15 VDC supply within the stated ±5% tolerance. Check both supply rails before connecting the instrument.
  2. Connector inspection: Verify the 15-pin D-sub connector and pin assignment against the applicable wiring documentation. Do not assume that visually similar connectors share the same pinout.
  3. Signal loading: Ensure the receiving input presents a load greater than 10 kΩ, as specified in the supplied data.
  4. Output scaling: Configure the controller for a 0–10 VDC pressure signal and the correct 10 Torr full-scale range.
  5. Mechanical connection: Confirm whether the installed unit uses a Tube or NW16-KF connection before attaching the vacuum line.
  6. Leak inspection: Check seals and connection surfaces after installation. Perform the equipment-approved leak test before process operation.
  7. Reading validation: Compare the indicated pressure with a suitable reference instrument under stable vacuum conditions.

Do not apply the maximum overpressure rating as a normal operating target. Pressure transients, mechanical shock, and contamination can affect sensor performance even when the electrical interface remains functional.

6. Replacement Selection: What Must Match?

A replacement decision should consider the full instrument configuration rather than the model family alone. The following checks help prevent installation delays and signal compatibility problems.

  • Range compatibility: Select a 10 Torr absolute range when the process measurement window and required resolution support this range.
  • Accuracy requirement: Compare the stated ±0.25% of reading specification with the process control tolerance.
  • Connection type: Confirm the actual D-option mechanical interface. A Tube fitting and an NW16-KF flange require different installation hardware.
  • Electrical connector: Verify the 15-pin D-sub connector, pinout, and cable compatibility.
  • Signal requirements: Confirm 0–10 VDC output compatibility and the receiving input impedance.
  • Power requirements: Check the ±15 VDC supply and available current capacity.
  • Process compatibility: Review the wetted materials against the actual gases and cleaning procedures.

When replacing an existing sensor, compare the complete nameplate and connector arrangement with the equipment documentation. A model from the same 626C family may still have a different range or connection configuration.

7. Maintenance and Troubleshooting Notes

Symptom Checks to Perform Engineering Response
Output voltage does not respond to pressure changes Power rails, connector wiring, and controller input Verify the ±15 VDC supply and signal path before replacing the sensor.
Displayed pressure differs from a reference gauge Signal scaling, reference conditions, and calibration history Check the 0–10 VDC conversion and compare readings under stable conditions.
Reading fluctuates during operation Electrical noise, grounding, pressure instability, and cable condition Separate process fluctuations from signal interference through independent measurements.
Vacuum performance changes after maintenance Connection seals, contamination, and installation condition Inspect the vacuum connection and perform the approved leak test.

Keep a record of calibration results, operating conditions, and maintenance history. These records help identify gradual measurement drift and distinguish instrument problems from vacuum-system faults. Avoid opening or modifying the sensing assembly without an approved service procedure.

8. Warranty and Shipping

  • Product: MKS Instruments 626C11TDE Baratron 626C Series pressure transducer.
  • Warranty: 12-month warranty.
  • Shipping Options: FedEx, UPS, and DHL.
  • Order Confirmation: Please provide the complete model number and confirm the mechanical connection before purchase.
  • Technical Support: Connector, pinout, and pressure-range information can be checked against the equipment requirements before order confirmation.

9. Frequently Asked Questions

Q1: Why can a 10 Torr sensor show a different pressure from a Pirani gauge in the same vacuum line?

The two instruments use different measurement principles. A capacitance manometer measures mechanical pressure, while a Pirani gauge responds to gas thermal conductivity. Gas composition and calibration conditions can therefore produce different readings. Use a suitable reference standard when evaluating measurement accuracy.

Q2: What should be checked if the transducer output is correct at the connector but incorrect on the HMI?

Inspect the analog input channel configuration, input impedance, signal common, grounding, and engineering-unit conversion. Confirm that the controller maps 0–10 VDC to the intended 0–10 Torr range. This check can prevent unnecessary sensor replacement.

Q3: Is a 10 Torr full-scale model always the best choice for a vacuum process?

Not necessarily. The expected operating pressure, process transients, required control margin, and measurement tolerance should guide range selection. A range that is too high may reduce useful signal utilization, while a range that is too low may expose the instrument to unsuitable pressure conditions.

Q4: How can maintenance teams identify an incorrect replacement connection before installation?

Compare the installed flange or tube outside diameter, sealing method, and equipment drawing with the replacement specification. Do not identify the connection from the single letter D alone. The supplied configuration descriptions conflict between 1/2-inch Tube and NW16-KF, so physical verification is essential.

Q5: What records are most useful when sourcing a replacement for an older vacuum instrument?

Keep the complete part number, equipment model, nameplate photograph, connector pinout, mounting dimensions, controller scaling, and process-gas information. These records help suppliers distinguish between similar models and reduce the risk of ordering a unit with an incompatible interface.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.