NBN4-12GM50-E2-V1 Pepperl+Fuchs NBN4 Inductive Sensor
Manufacturer: Pepperl+Fuchs
Product No.: NBN4-12GM50-E2-V1
Condition: En stock
Product Type: Inductive Sensor
Product Origin: DE
Payment: T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).
Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.
Pago Seguro Garantizado
Product Overview – Precision Detection in Compact Installations
The NBN4-12GM50-E2-V1 is a Pepperl+Fuchs NBN4 Series inductive proximity sensor. It detects metallic objects without physical contact. Its 4 mm sensing distance supports reliable position detection in industrial automation systems.
This sensor features a non-flush mounting configuration and a three-wire PNP switching output. Its normally open switching function simplifies integration with compatible PLC digital inputs and control circuits.
The extended operating temperature range covers -40°C to +85°C. Its wide 5–36 V DC supply range supports flexible installation across different industrial control architectures.
A brass housing with white bronze coating provides mechanical protection. The PBT sensing face and IP68 enclosure rating support demanding installation environments.
Technical Identity & Performance Profile
| Specification | Technical Details |
| Manufacturer | Pepperl+Fuchs |
| Model | NBN4-12GM50-E2-V1 |
| Product Series | NBN4 |
| Product Type | Inductive Proximity Sensor |
| Detection Principle | Inductive, non-contact metallic detection |
| Rated Sensing Distance | 4 mm |
| Mounting Configuration | Non-flush |
| Assured Operating Distance | 0–3.24 mm |
| Switching Function | Normally Open (NO) |
| Output Type | PNP, DC, 3-wire |
| Supply Voltage | 5–36 V DC |
| Maximum Switching Frequency | 2,650 Hz |
| Typical Hysteresis | 5% |
| Maximum Operating Current | 200 mA |
| Voltage Drop | ≤1 V |
| Maximum Off-State Current | 20 µA |
| No-Load Supply Current | ≤10 mA |
| Operating Temperature | -40°C to +85°C |
| Storage Temperature | -40°C to +85°C |
| Protection Rating | IP68 |
| Housing Material | Brass, white bronze coated |
| Sensing Face Material | Green PBT |
| Connection | M12 x 1 connector plug |
| Connector Pins | 3 |
| Protection Class | II |
| Weight | 28 g |
| Maximum Tightening Torque | 10 Nm |
| Switching Indicator | Yellow multi-hole LED |
Detection Characteristics & Material Compensation
The sensor uses an inductive detection field to identify approaching metal targets. Its rated sensing distance is 4 mm under the specified reference conditions.
Reference target conditions:
- Material: Mild steel, such as 1.0037 or SR235JR (formerly St37-2).
- Target dimensions: 12 x 12 x 1 mm.
- Rated sensing distance: 4 mm.
- Assured operating distance: 0–3.24 mm.
Different metal compositions produce different sensing distances. Apply the following reduction factors during target selection.
| Target Material | Reduction Factor |
| Aluminum | 0.47 |
| Copper | 0.43 |
| Stainless Steel 304 | 0.85 |
| Brass | 0.55 |
For example, aluminum produces a shorter effective detection distance than mild steel. Engineers should account for this difference when setting mechanical clearances.
Electrical Interface & Output Protection
The three-wire PNP output provides a switching signal for compatible DC control inputs. The normally open configuration changes its output state when a suitable metal target enters the sensing zone.
- Supply voltage: 5–36 V DC.
- Load current: 0–200 mA.
- Voltage drop: Maximum 1 V.
- Switching frequency: Up to 2,650 Hz.
- Reverse polarity protection: Integrated.
- Short-circuit protection: Pulsing protection.
- Availability delay: Maximum 10 ms.
The integrated protection functions help reduce electrical damage during common wiring faults. However, they do not replace correct power supply selection or circuit protection.
The yellow LED provides a convenient visual indication of switching activity. Maintenance personnel can use this indicator during initial commissioning and fault investigation.
Mechanical Design & Environmental Protection
The cylindrical housing uses brass with a white bronze coating. Its green PBT sensing face provides the front detection surface.
- Enclosure protection: IP68.
- Temperature capability: -40°C to +85°C.
- Connector interface: M12 x 1.
- Mounting: Non-flush installation.
- Mechanical weight: 28 g.
- Tightening torque: 0–10 Nm.
The IP68 rating supports installations exposed to dust and water ingress. Actual suitability depends on the application's immersion conditions and connector sealing.
The extended temperature range supports equipment installed in cold outdoor environments and warmer industrial machinery areas.
Installation & Commissioning Recommendations
1. Mechanical Installation
- Confirm the available mounting space before installation.
- Allow sufficient clearance for the non-flush sensing field.
- Keep nearby metal structures outside the effective sensing zone unless the installation design permits them.
- Secure the sensor with the supplied self-locking nuts.
- Apply tightening torque within the specified 10 Nm maximum.
2. Electrical Connection
- Use a compatible three-pin M12 x 1 connector.
- Verify the supply voltage remains within 5–36 V DC.
- Match the PNP output to the receiving PLC input type.
- Confirm the connected load does not exceed 200 mA.
- Check polarity before energizing the circuit.
3. Functional Commissioning
- Apply power and allow up to 10 ms for availability.
- Move a suitable metal target toward the sensing face.
- Observe the yellow LED switching indication.
- Check the PLC input state during target movement.
- Verify reliable switching at the actual operating distance.
Use the assured operating distance for application design. Do not position the target at the nominal 4 mm limit without considering material and installation tolerances.
Maintenance & Troubleshooting Considerations
| Observed Condition | Recommended Engineering Check |
| No switching response | Check supply voltage, target material, and sensing distance. |
| Unstable PLC input | Inspect connector seating, wiring polarity, and target movement. |
| Reduced detection distance | Verify the target material and its reduction factor. |
| Continuous output signal | Check nearby metal objects and mounting clearances. |
| Intermittent operation | Inspect cable connections, vibration, and mechanical mounting. |
| LED remains inactive | Measure the supply voltage and inspect the connection circuit. |
Routine maintenance should include connector inspection, sensing-face cleaning, and mounting checks. Remove accumulated metallic particles before testing detection performance.
Standards, Certifications & Functional Safety Data
- EN 60947-5-2:2007
- EN 60947-5-2/A1:2012
- IEC 60947-5-2:2007
- IEC 60947-5-2 AMD 1:2012
- EAC: TR CU 020/2011 conformity.
- UL: cULus Listed, General Purpose, Class 2 Power Source.
- CCC: Approval marking not required for products rated at 36 V or below.
- PWIS: VDMA 24364-A1/B2/C1/T100°C-W conformity.
Insulation characteristics:
- Rated insulation voltage Ui: 36 V.
- Rated impulse withstand voltage Uimp: 500 V.
- Protection class: II.
Functional safety-related data:
- MTTFd: 1,707 years.
- Mission time (TM): 20 years.
- Diagnostic coverage (DC): 0%.
These reliability figures do not establish a standalone safety integrity level. Do not use this sensor as a safety-rated device without an approved system-level assessment.
Package Contents
- 1 x Pepperl+Fuchs NBN4-12GM50-E2-V1 inductive proximity sensor.
- 2 x Self-locking mounting nuts.
The connector plug is part of the sensor connection configuration. Confirm any additional cable or mating connector requirements before ordering.
Frequently Asked Questions – Application Engineering
Q1: Why can a metal target trigger this sensor at different distances?
Inductive sensing performance depends on target conductivity, permeability, size, and geometry. Reference measurements use a defined mild-steel target. Smaller targets or different alloys can reduce the effective detection distance.
Q2: What happens when the sensor operates near the maximum switching frequency?
Target movement becomes a critical design factor. At high switching rates, the target must provide sufficient detection time within each sensing cycle. Verify actual response under the machine's operating speed.
Q3: How should engineers handle unwanted switching caused by nearby metal structures?
Review the sensor's mounting geometry and surrounding conductive materials. Adjust the installation position or mechanical clearance where possible. Test the complete assembly rather than evaluating the sensor separately.
Q4: Is the NBN4-12GM50-E2-V1 suitable for direct connection to every PLC input?
No. The sensor provides a PNP output, so the receiving input must support compatible PNP switching logic. Check the PLC input voltage, current requirements, and common-terminal arrangement before wiring.
Q5: What should buyers verify when replacing an existing proximity sensor?
Compare the sensing distance, non-flush mounting geometry, output polarity, connector arrangement, supply voltage, and operating temperature. Also check the mounting dimensions and target material. Matching only the M12 connector does not guarantee electrical or mechanical compatibility.

Tags
P: ¿Son estas piezas 100% originales y nuevas?
R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.
P: ¿Qué tan rápido es el envío a mi país?
R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.
P: ¿Puedo obtener una cotización formal con los costos de envío?
R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.
P: ¿Ofrecen descuentos por pedidos al por mayor?
R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.
Garantía Integral de 12 Meses
Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.
- Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
- Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.
Política de Devoluciones y Cambios
Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.
- Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
- Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
- Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.
¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.