Home VFD055E43A Delta Sensorless Vector Micro AC Drive VFD-E 5.5kW
VFD055E43A Delta Sensorless Vector Micro AC Drive VFD-E 5.5kW
VFD055E43A Delta Sensorless Vector Micro AC Drive VFD-E 5.5kW
VFD055E43A Delta Sensorless Vector Micro AC Drive VFD-E 5.5kW
VFD055E43A Delta Sensorless Vector Micro AC Drive VFD-E 5.5kW
VFD055E43A Delta Sensorless Vector Micro AC Drive VFD-E 5.5kW
VFD055E43A Delta Sensorless Vector Micro AC Drive VFD-E 5.5kW

VFD055E43A Delta Sensorless Vector Micro AC Drive VFD-E 5.5kW

  • Manufacturer: Delta

  • Product No.: VFD055E43A

  • Condition: In stock

  • Product Type: AC Drive

  • Product Origin: CN

  • Payment: T/T, Western Union

  • Weight: 4200g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Delta VFD055E43A VFD-E Series 7.5 HP AC Micro Drive Overview

The Delta VFD055E43A represents the VFD-E Series modular micro AC drive family. Delta engineered this compact inverter specifically for constant torque applications requiring precise motor velocity and flexible logic processing. Integrating an internal programmable logic controller with extension card support, the VFD055E43A executes simple ladder programs locally to eliminate intermediate relay networks and shrink panel real estate.

Key Technical Specifications

  • Brand: Delta Electronics
  • Model Number: VFD055E43A
  • Series: VFD-E Series
  • Nominal Capacity: 7.5 HP (5.5 kW) Constant Torque
  • Mains Voltage: 380 V AC to 480 V AC (3-Phase Input / 3-Phase Output)
  • Continuous Current: 13 A Output
  • Output Frequency: 0.1 Hz to 600 Hz
  • Motor Control Method: Open Loop Sensorless Vector Control
  • Frequency Resolution: 0.01 Hz (Digital Command), 0.06 Hz / 60 Hz (Analog Input)
  • Speed Regulation Accuracy: ±0.5% (Open Loop Vector)
  • Torque Response Linearity: ±5%
  • Operating Temperature: -10°C to +50°C (14°F to 122°F)
  • Environmental & Protection Rating: IP20, Pollution Degree 2
  • Electromagnetic Immunity: EN61800-3 Standard Compliant
  • Braking Mechanism: Internal Dynamic Braking Transistor & DC Injection
  • Cooling System: Forced Air Cooling Fan
  • Physical Dimensions: Height 10.24 in x Width 4.57 in x Depth 6.66 in (Frame C)
  • Unit Weight: 4.2 kg (9.26 lbs)
  • Certifications: CE, UL, cUL, RoHS Compliant

Architectural & Operational Capabilities

Functionality Operational Advantage
Embedded PLC Engine Executes user-defined ladder programs to direct local process loops without an external controller.
Modular Expansion Interface Accommodates optional fieldbus cards, digital/analog I/O cards, and encoder feed modules.
Integrated Dynamic Braking Features an internal chopper transistor for direct braking resistor attachment during fast deceleration.
Built-in RFI Filter Switch Allows fast noise attenuation adjustments on mains supply topologies.
Shared DC Bus Connection Enables multiple drive DC link connections to recycle regenerative energy efficiently.
Compact Frame C Enclosure IP20 rating supports dense side-by-side mounting inside standard control cabinets.

Targeted Equipment & Industrial Applications

  • High-Inertia Mixing Equipment: Provides high starting torque for heavy industrial agitators, blenders, and extruders without stalling.
  • Centrifugal Pumping Stations: Controls multi-pump pressure loops utilizing embedded PID control and local PLC sequencing.
  • Material Handling Conveyors: Manages precise acceleration profiles and smooth deceleration ramps for packaging and sorting lines.
  • Metalworking & Machine Tools: Drives high-speed spindles requiring output frequencies up to 600 Hz with tight speed stability.
  • HVAC Fan Systems: Adjusts airflow based on differential pressure or temperature sensor feedback to reduce electrical consumption.

Mounting & Physical Installation Protocols

  • Install the drive vertically on a flat, non-flammable substrate inside an IP20 or higher industrial enclosure.
  • Maintain a minimum clear space of 50 mm (2 inches) above and below the drive frame to ensure proper fan airflow.
  • Connect incoming 460V 3-phase mains lines to terminals L1, L2, L3 and motor leads to U, V, W.
  • Bond dedicated ground cables directly to the drive ground terminal using low-impedance ground buses.
  • Fit an line reactor ahead of the power inputs if upstream transformer rating exceeds 500 kVA.

Parameterization & Maintenance Workflow

  • View active drive parameters and fault codes through the built-in LED interface or plug-in keypad module.
  • Execute a motor auto-tuning routine before initiating sensorless vector mode to calculate stator resistance and inductance automatically.
  • Clean cooling fan blades and heat sink fins every six months to prevent thermal derating.
  • Verify electrical terminal screw tightness annually to mitigate high-resistance hot spots.
  • Track DC bus voltage and operational hours through internal monitor parameters during scheduled service intervals.

Diagnostic Logic & Fault Monitoring Capabilities

  • Integrated microprocessor monitors phase-to-phase output short circuits, phase loss, and line under-voltage conditions.
  • Drive logs real-time error history including thermal overload, overcurrent, and DC overvoltage fault codes.
  • Integrated motor thermal memory protection prevents thermal breakdown of motor windings.
  • Electronic current limiting suppresses momentary peak loads to prevent nuisance fault tripping during sudden load changes.

Global PLC Spare HUB's Insight

During field service retrofits, the Delta VFD055E43A consistently proves itself as an economical replacement for older 7.5 HP micro drives. On a recent packaging machine rebuild, an engineer utilized the onboard PLC logic of the VFD055E43A to read a photoelectric sensor directly and execute an automatic indexing pause. This setup allowed the customer to bypass an aging standalone micro-PLC, simplifying control cabinet wiring and cutting total commissioning time by 6 hours.

Technical Selection Guide

  • Verify motor nameplate current does not exceed the VFD055E43A continuous rating of 13 A at 460V.
  • Select an external dynamic braking resistor if your application involves high-inertia stops or overhauling loads.
  • Include the optional digital keypad (KPE-LE02) in your order if parameter cloning or remote door-mounting is required.
  • Add an optional fieldbus card (Profibus, DeviceNet, or CANopen) when integrating into larger supervisory network architectures.

Fulfillment, Shipping & Factory Warranty

  • Standard Package Contents: 1 x Delta VFD055E43A Inverter Drive, Hardware Kit, Quick Reference Manual.
  • Order Processing: Fast warehouse handling and dispatch within 24 to 48 hours.
  • Global Express Shipping: Tracked worldwide transit via FedEx, UPS, and DHL.
  • Warranty Protection: Backed by a comprehensive 12-Month Quality Warranty.

Frequently Asked Questions

What is the difference between the VFD055E43A and higher amp models in the VFD-E series?

The VFD055E43A output current peaks at 13 A for 7.5 HP motors, utilizing Frame C dimensions with a built-in fan.

How do I clear an Overvoltage (hp/ov) fault during motor deceleration?

Extend the deceleration time parameter (Pr.01-10) or connect an external braking resistor across terminals (+/B1 and B2).

Can I operate a 230V 3-phase motor using this specific drive model?

No, the VFD055E43A operates exclusively on a 380V-480V 3-phase input and outputs voltage proportional to its 460V class power supply.

Is the programming software for the onboard PLC free to download?

Yes, Delta provides WPLSoft programming software free of charge for editing ladder logic and transferring software routines via RS-485.

What should I inspect if the drive fan fails to spin when powered up?

The cooling fan operates based on heat sink temperature algorithms; check parameter settings or inspect the fan connector on Frame C if thermal thresholds are reached without fan activation.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.